Cargando…
Estimation of the Corneal Young's Modulus In Vivo Based on a Fluid-Filled Spherical-Shell Model with Scheimpflug Imaging
Current intraocular pressure (IOP) measurement using air puff could be erroneous without applying proper corrections. Although noncontact tonometry is not considered to be accurate, it is still popularly used by eye clinics. It is thus necessary to extract the correct information from their results....
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5698833/ https://www.ncbi.nlm.nih.gov/pubmed/29250440 http://dx.doi.org/10.1155/2017/5410143 |
_version_ | 1783280836967137280 |
---|---|
author | Shih, Po-Jen Huang, Chun-Ju Huang, Tzu-Han Lin, Hung-Chou Yen, Jia-Yush Wang, I-Jong Cao, Hui-Jyun Shih, Wen-Pin Dai, Chi-An |
author_facet | Shih, Po-Jen Huang, Chun-Ju Huang, Tzu-Han Lin, Hung-Chou Yen, Jia-Yush Wang, I-Jong Cao, Hui-Jyun Shih, Wen-Pin Dai, Chi-An |
author_sort | Shih, Po-Jen |
collection | PubMed |
description | Current intraocular pressure (IOP) measurement using air puff could be erroneous without applying proper corrections. Although noncontact tonometry is not considered to be accurate, it is still popularly used by eye clinics. It is thus necessary to extract the correct information from their results. This study proposes a practical approach to correctly measure IOP in vivo. By embedding a new model-based correction to the Corvis® ST, we can extract the corneal Young's modulus from the patient data. This Young's modulus can be used to correct the IOP readings. The tests were applied to 536 right eyes of 536 healthy subjects (228 male and 308 female) between March of 2012 and April of 2016. The tests were applied to patients at the Department of Ophthalmology, National Taiwan University Hospital and the Hung-Chuo Eye Clinics. The statistical analysis showed that the value for the Young's modulus was independent of all the other parameters collected from the Corvis ST, including the corneal thickness and the intraocular pressure. Therefore, it is important to independently measure the Young's modulus instead of depending on the correlation with the other parameters. This study adds the methodology of measuring corneal stiffness in vivo for ophthalmologists' reference in diagnosis. |
format | Online Article Text |
id | pubmed-5698833 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-56988332017-12-17 Estimation of the Corneal Young's Modulus In Vivo Based on a Fluid-Filled Spherical-Shell Model with Scheimpflug Imaging Shih, Po-Jen Huang, Chun-Ju Huang, Tzu-Han Lin, Hung-Chou Yen, Jia-Yush Wang, I-Jong Cao, Hui-Jyun Shih, Wen-Pin Dai, Chi-An J Ophthalmol Research Article Current intraocular pressure (IOP) measurement using air puff could be erroneous without applying proper corrections. Although noncontact tonometry is not considered to be accurate, it is still popularly used by eye clinics. It is thus necessary to extract the correct information from their results. This study proposes a practical approach to correctly measure IOP in vivo. By embedding a new model-based correction to the Corvis® ST, we can extract the corneal Young's modulus from the patient data. This Young's modulus can be used to correct the IOP readings. The tests were applied to 536 right eyes of 536 healthy subjects (228 male and 308 female) between March of 2012 and April of 2016. The tests were applied to patients at the Department of Ophthalmology, National Taiwan University Hospital and the Hung-Chuo Eye Clinics. The statistical analysis showed that the value for the Young's modulus was independent of all the other parameters collected from the Corvis ST, including the corneal thickness and the intraocular pressure. Therefore, it is important to independently measure the Young's modulus instead of depending on the correlation with the other parameters. This study adds the methodology of measuring corneal stiffness in vivo for ophthalmologists' reference in diagnosis. Hindawi 2017 2017-11-08 /pmc/articles/PMC5698833/ /pubmed/29250440 http://dx.doi.org/10.1155/2017/5410143 Text en Copyright © 2017 Po-Jen Shih et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Shih, Po-Jen Huang, Chun-Ju Huang, Tzu-Han Lin, Hung-Chou Yen, Jia-Yush Wang, I-Jong Cao, Hui-Jyun Shih, Wen-Pin Dai, Chi-An Estimation of the Corneal Young's Modulus In Vivo Based on a Fluid-Filled Spherical-Shell Model with Scheimpflug Imaging |
title | Estimation of the Corneal Young's Modulus In Vivo Based on a Fluid-Filled Spherical-Shell Model with Scheimpflug Imaging |
title_full | Estimation of the Corneal Young's Modulus In Vivo Based on a Fluid-Filled Spherical-Shell Model with Scheimpflug Imaging |
title_fullStr | Estimation of the Corneal Young's Modulus In Vivo Based on a Fluid-Filled Spherical-Shell Model with Scheimpflug Imaging |
title_full_unstemmed | Estimation of the Corneal Young's Modulus In Vivo Based on a Fluid-Filled Spherical-Shell Model with Scheimpflug Imaging |
title_short | Estimation of the Corneal Young's Modulus In Vivo Based on a Fluid-Filled Spherical-Shell Model with Scheimpflug Imaging |
title_sort | estimation of the corneal young's modulus in vivo based on a fluid-filled spherical-shell model with scheimpflug imaging |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5698833/ https://www.ncbi.nlm.nih.gov/pubmed/29250440 http://dx.doi.org/10.1155/2017/5410143 |
work_keys_str_mv | AT shihpojen estimationofthecornealyoungsmodulusinvivobasedonafluidfilledsphericalshellmodelwithscheimpflugimaging AT huangchunju estimationofthecornealyoungsmodulusinvivobasedonafluidfilledsphericalshellmodelwithscheimpflugimaging AT huangtzuhan estimationofthecornealyoungsmodulusinvivobasedonafluidfilledsphericalshellmodelwithscheimpflugimaging AT linhungchou estimationofthecornealyoungsmodulusinvivobasedonafluidfilledsphericalshellmodelwithscheimpflugimaging AT yenjiayush estimationofthecornealyoungsmodulusinvivobasedonafluidfilledsphericalshellmodelwithscheimpflugimaging AT wangijong estimationofthecornealyoungsmodulusinvivobasedonafluidfilledsphericalshellmodelwithscheimpflugimaging AT caohuijyun estimationofthecornealyoungsmodulusinvivobasedonafluidfilledsphericalshellmodelwithscheimpflugimaging AT shihwenpin estimationofthecornealyoungsmodulusinvivobasedonafluidfilledsphericalshellmodelwithscheimpflugimaging AT daichian estimationofthecornealyoungsmodulusinvivobasedonafluidfilledsphericalshellmodelwithscheimpflugimaging |