Cargando…

Estimation of the Corneal Young's Modulus In Vivo Based on a Fluid-Filled Spherical-Shell Model with Scheimpflug Imaging

Current intraocular pressure (IOP) measurement using air puff could be erroneous without applying proper corrections. Although noncontact tonometry is not considered to be accurate, it is still popularly used by eye clinics. It is thus necessary to extract the correct information from their results....

Descripción completa

Detalles Bibliográficos
Autores principales: Shih, Po-Jen, Huang, Chun-Ju, Huang, Tzu-Han, Lin, Hung-Chou, Yen, Jia-Yush, Wang, I-Jong, Cao, Hui-Jyun, Shih, Wen-Pin, Dai, Chi-An
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5698833/
https://www.ncbi.nlm.nih.gov/pubmed/29250440
http://dx.doi.org/10.1155/2017/5410143
_version_ 1783280836967137280
author Shih, Po-Jen
Huang, Chun-Ju
Huang, Tzu-Han
Lin, Hung-Chou
Yen, Jia-Yush
Wang, I-Jong
Cao, Hui-Jyun
Shih, Wen-Pin
Dai, Chi-An
author_facet Shih, Po-Jen
Huang, Chun-Ju
Huang, Tzu-Han
Lin, Hung-Chou
Yen, Jia-Yush
Wang, I-Jong
Cao, Hui-Jyun
Shih, Wen-Pin
Dai, Chi-An
author_sort Shih, Po-Jen
collection PubMed
description Current intraocular pressure (IOP) measurement using air puff could be erroneous without applying proper corrections. Although noncontact tonometry is not considered to be accurate, it is still popularly used by eye clinics. It is thus necessary to extract the correct information from their results. This study proposes a practical approach to correctly measure IOP in vivo. By embedding a new model-based correction to the Corvis® ST, we can extract the corneal Young's modulus from the patient data. This Young's modulus can be used to correct the IOP readings. The tests were applied to 536 right eyes of 536 healthy subjects (228 male and 308 female) between March of 2012 and April of 2016. The tests were applied to patients at the Department of Ophthalmology, National Taiwan University Hospital and the Hung-Chuo Eye Clinics. The statistical analysis showed that the value for the Young's modulus was independent of all the other parameters collected from the Corvis ST, including the corneal thickness and the intraocular pressure. Therefore, it is important to independently measure the Young's modulus instead of depending on the correlation with the other parameters. This study adds the methodology of measuring corneal stiffness in vivo for ophthalmologists' reference in diagnosis.
format Online
Article
Text
id pubmed-5698833
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-56988332017-12-17 Estimation of the Corneal Young's Modulus In Vivo Based on a Fluid-Filled Spherical-Shell Model with Scheimpflug Imaging Shih, Po-Jen Huang, Chun-Ju Huang, Tzu-Han Lin, Hung-Chou Yen, Jia-Yush Wang, I-Jong Cao, Hui-Jyun Shih, Wen-Pin Dai, Chi-An J Ophthalmol Research Article Current intraocular pressure (IOP) measurement using air puff could be erroneous without applying proper corrections. Although noncontact tonometry is not considered to be accurate, it is still popularly used by eye clinics. It is thus necessary to extract the correct information from their results. This study proposes a practical approach to correctly measure IOP in vivo. By embedding a new model-based correction to the Corvis® ST, we can extract the corneal Young's modulus from the patient data. This Young's modulus can be used to correct the IOP readings. The tests were applied to 536 right eyes of 536 healthy subjects (228 male and 308 female) between March of 2012 and April of 2016. The tests were applied to patients at the Department of Ophthalmology, National Taiwan University Hospital and the Hung-Chuo Eye Clinics. The statistical analysis showed that the value for the Young's modulus was independent of all the other parameters collected from the Corvis ST, including the corneal thickness and the intraocular pressure. Therefore, it is important to independently measure the Young's modulus instead of depending on the correlation with the other parameters. This study adds the methodology of measuring corneal stiffness in vivo for ophthalmologists' reference in diagnosis. Hindawi 2017 2017-11-08 /pmc/articles/PMC5698833/ /pubmed/29250440 http://dx.doi.org/10.1155/2017/5410143 Text en Copyright © 2017 Po-Jen Shih et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Shih, Po-Jen
Huang, Chun-Ju
Huang, Tzu-Han
Lin, Hung-Chou
Yen, Jia-Yush
Wang, I-Jong
Cao, Hui-Jyun
Shih, Wen-Pin
Dai, Chi-An
Estimation of the Corneal Young's Modulus In Vivo Based on a Fluid-Filled Spherical-Shell Model with Scheimpflug Imaging
title Estimation of the Corneal Young's Modulus In Vivo Based on a Fluid-Filled Spherical-Shell Model with Scheimpflug Imaging
title_full Estimation of the Corneal Young's Modulus In Vivo Based on a Fluid-Filled Spherical-Shell Model with Scheimpflug Imaging
title_fullStr Estimation of the Corneal Young's Modulus In Vivo Based on a Fluid-Filled Spherical-Shell Model with Scheimpflug Imaging
title_full_unstemmed Estimation of the Corneal Young's Modulus In Vivo Based on a Fluid-Filled Spherical-Shell Model with Scheimpflug Imaging
title_short Estimation of the Corneal Young's Modulus In Vivo Based on a Fluid-Filled Spherical-Shell Model with Scheimpflug Imaging
title_sort estimation of the corneal young's modulus in vivo based on a fluid-filled spherical-shell model with scheimpflug imaging
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5698833/
https://www.ncbi.nlm.nih.gov/pubmed/29250440
http://dx.doi.org/10.1155/2017/5410143
work_keys_str_mv AT shihpojen estimationofthecornealyoungsmodulusinvivobasedonafluidfilledsphericalshellmodelwithscheimpflugimaging
AT huangchunju estimationofthecornealyoungsmodulusinvivobasedonafluidfilledsphericalshellmodelwithscheimpflugimaging
AT huangtzuhan estimationofthecornealyoungsmodulusinvivobasedonafluidfilledsphericalshellmodelwithscheimpflugimaging
AT linhungchou estimationofthecornealyoungsmodulusinvivobasedonafluidfilledsphericalshellmodelwithscheimpflugimaging
AT yenjiayush estimationofthecornealyoungsmodulusinvivobasedonafluidfilledsphericalshellmodelwithscheimpflugimaging
AT wangijong estimationofthecornealyoungsmodulusinvivobasedonafluidfilledsphericalshellmodelwithscheimpflugimaging
AT caohuijyun estimationofthecornealyoungsmodulusinvivobasedonafluidfilledsphericalshellmodelwithscheimpflugimaging
AT shihwenpin estimationofthecornealyoungsmodulusinvivobasedonafluidfilledsphericalshellmodelwithscheimpflugimaging
AT daichian estimationofthecornealyoungsmodulusinvivobasedonafluidfilledsphericalshellmodelwithscheimpflugimaging