Cargando…
Interpreting myocardial perfusion scintigraphy using single-photon emission computed tomography. Part 1
This article discusses the protocol for myocardial perfusion scintigraphy performed with single-photon emission computed tomography (SPECT). Indications for SPECT are listed with consideration given to the results of the increasingly more common angio-CT examinations of the coronary arteries (multis...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Termedia Publishing House
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5701596/ https://www.ncbi.nlm.nih.gov/pubmed/29181048 http://dx.doi.org/10.5114/kitp.2017.70534 |
_version_ | 1783281374932762624 |
---|---|
author | Czaja, Monika Wygoda, Zbigniew Duszańska, Agata Szczerba, Dominik Głowacki, Jan Gąsior, Mariusz Wasilewski, Jarosław P. |
author_facet | Czaja, Monika Wygoda, Zbigniew Duszańska, Agata Szczerba, Dominik Głowacki, Jan Gąsior, Mariusz Wasilewski, Jarosław P. |
author_sort | Czaja, Monika |
collection | PubMed |
description | This article discusses the protocol for myocardial perfusion scintigraphy performed with single-photon emission computed tomography (SPECT). Indications for SPECT are listed with consideration given to the results of the increasingly more common angio-CT examinations of the coronary arteries (multislice computed tomography). The paper also presents basic information about interpreting the results, including the scores of left ventricle myocardial perfusion using the 17-segment polar map, and explains the concept of total perfusion deficit. |
format | Online Article Text |
id | pubmed-5701596 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Termedia Publishing House |
record_format | MEDLINE/PubMed |
spelling | pubmed-57015962017-11-27 Interpreting myocardial perfusion scintigraphy using single-photon emission computed tomography. Part 1 Czaja, Monika Wygoda, Zbigniew Duszańska, Agata Szczerba, Dominik Głowacki, Jan Gąsior, Mariusz Wasilewski, Jarosław P. Kardiochir Torakochirurgia Pol Review Paper This article discusses the protocol for myocardial perfusion scintigraphy performed with single-photon emission computed tomography (SPECT). Indications for SPECT are listed with consideration given to the results of the increasingly more common angio-CT examinations of the coronary arteries (multislice computed tomography). The paper also presents basic information about interpreting the results, including the scores of left ventricle myocardial perfusion using the 17-segment polar map, and explains the concept of total perfusion deficit. Termedia Publishing House 2017-09-30 2017-09 /pmc/articles/PMC5701596/ /pubmed/29181048 http://dx.doi.org/10.5114/kitp.2017.70534 Text en Copyright: © 2017 Polish Society of Cardiothoracic Surgeons (Polskie Towarzystwo KardioTorakochirurgów) and the editors of the Polish Journal of Cardio-Thoracic Surgery (Kardiochirurgia i Torakochirurgia Polska) http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license. |
spellingShingle | Review Paper Czaja, Monika Wygoda, Zbigniew Duszańska, Agata Szczerba, Dominik Głowacki, Jan Gąsior, Mariusz Wasilewski, Jarosław P. Interpreting myocardial perfusion scintigraphy using single-photon emission computed tomography. Part 1 |
title | Interpreting myocardial perfusion scintigraphy using single-photon emission computed tomography. Part 1 |
title_full | Interpreting myocardial perfusion scintigraphy using single-photon emission computed tomography. Part 1 |
title_fullStr | Interpreting myocardial perfusion scintigraphy using single-photon emission computed tomography. Part 1 |
title_full_unstemmed | Interpreting myocardial perfusion scintigraphy using single-photon emission computed tomography. Part 1 |
title_short | Interpreting myocardial perfusion scintigraphy using single-photon emission computed tomography. Part 1 |
title_sort | interpreting myocardial perfusion scintigraphy using single-photon emission computed tomography. part 1 |
topic | Review Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5701596/ https://www.ncbi.nlm.nih.gov/pubmed/29181048 http://dx.doi.org/10.5114/kitp.2017.70534 |
work_keys_str_mv | AT czajamonika interpretingmyocardialperfusionscintigraphyusingsinglephotonemissioncomputedtomographypart1 AT wygodazbigniew interpretingmyocardialperfusionscintigraphyusingsinglephotonemissioncomputedtomographypart1 AT duszanskaagata interpretingmyocardialperfusionscintigraphyusingsinglephotonemissioncomputedtomographypart1 AT szczerbadominik interpretingmyocardialperfusionscintigraphyusingsinglephotonemissioncomputedtomographypart1 AT głowackijan interpretingmyocardialperfusionscintigraphyusingsinglephotonemissioncomputedtomographypart1 AT gasiormariusz interpretingmyocardialperfusionscintigraphyusingsinglephotonemissioncomputedtomographypart1 AT wasilewskijarosławp interpretingmyocardialperfusionscintigraphyusingsinglephotonemissioncomputedtomographypart1 |