The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap

STATEMENT OF THE PROBLEM: Precision of the impression taken from implant positions significantly determines accurate fit of implant-supported prostheses. An imprecise impression may produce prosthesis misfit. PURPOSE: This study aimed to evaluate the accuracy of four impression-making techniques for...

Descripción completa

Detalles Bibliográficos
Autores principales: Saboury, Abolfazl, Neshandar Asli, Hamid, Dalili Kajan, Zahra
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Journal of Dentistry Shiraz University of Medical Sciences 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5702434/
https://www.ncbi.nlm.nih.gov/pubmed/29201973
_version_ 1783281529987792896
author Saboury, Abolfazl
Neshandar Asli, Hamid
Dalili Kajan, Zahra
author_facet Saboury, Abolfazl
Neshandar Asli, Hamid
Dalili Kajan, Zahra
author_sort Saboury, Abolfazl
collection PubMed
description STATEMENT OF THE PROBLEM: Precision of the impression taken from implant positions significantly determines accurate fit of implant-supported prostheses. An imprecise impression may produce prosthesis misfit. PURPOSE: This study aimed to evaluate the accuracy of four impression-making techniques for angulated implants by stereomicroscope through measuring the vertical marginal gaps between the cemented metal framework and the implant analog. MATERIALS AND METHOD: A definitive cast with two 15° mesially angulated implants served as the standard reference for making all the impressions and later for accuracy evaluation. Four groups of five samples were evaluated: (1) closed-tray snap-fit transfer, (2) open-tray nonsplinted impression coping, (3) metal splinted impression coping, and (4) fabricated acrylic resin transfer cap. A gold-palladium framework was fabricated over the angulated implant abutments, the fit of which was used as reference. The gaps between the metal framework and the implant analogs were measured in sample groups. Corresponding means for each technique and the definitive cast were compared by using ANOVA and post hoc tests. RESULTS: The mean marginal gap was 38.16±0µm in definitive cast, 89±19.74µm in group 1, 78.66±20.63µm in group 2, 54.16±24.29µm in group 3, and 55.83±18.30µm in group 4. ANOVA revealed significant differences between the definitive cast and groups 1 and 2, but not with groups 3 and 4 (p< 0.05). CONCLUSION: Vertical gap measurements showed that metal splinted impression coping and fabricated acrylic resin transfer cap techniques produced quite more accurate impressions than closed-tray snap-fit transfer and open-tray nonsplinted impression coping techniques do. The fabricated acrylic resin transfer cap technique seems to be a reliable impression-making method.
format Online
Article
Text
id pubmed-5702434
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Journal of Dentistry Shiraz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-57024342017-12-01 The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap Saboury, Abolfazl Neshandar Asli, Hamid Dalili Kajan, Zahra J Dent (Shiraz) Original Article STATEMENT OF THE PROBLEM: Precision of the impression taken from implant positions significantly determines accurate fit of implant-supported prostheses. An imprecise impression may produce prosthesis misfit. PURPOSE: This study aimed to evaluate the accuracy of four impression-making techniques for angulated implants by stereomicroscope through measuring the vertical marginal gaps between the cemented metal framework and the implant analog. MATERIALS AND METHOD: A definitive cast with two 15° mesially angulated implants served as the standard reference for making all the impressions and later for accuracy evaluation. Four groups of five samples were evaluated: (1) closed-tray snap-fit transfer, (2) open-tray nonsplinted impression coping, (3) metal splinted impression coping, and (4) fabricated acrylic resin transfer cap. A gold-palladium framework was fabricated over the angulated implant abutments, the fit of which was used as reference. The gaps between the metal framework and the implant analogs were measured in sample groups. Corresponding means for each technique and the definitive cast were compared by using ANOVA and post hoc tests. RESULTS: The mean marginal gap was 38.16±0µm in definitive cast, 89±19.74µm in group 1, 78.66±20.63µm in group 2, 54.16±24.29µm in group 3, and 55.83±18.30µm in group 4. ANOVA revealed significant differences between the definitive cast and groups 1 and 2, but not with groups 3 and 4 (p< 0.05). CONCLUSION: Vertical gap measurements showed that metal splinted impression coping and fabricated acrylic resin transfer cap techniques produced quite more accurate impressions than closed-tray snap-fit transfer and open-tray nonsplinted impression coping techniques do. The fabricated acrylic resin transfer cap technique seems to be a reliable impression-making method. Journal of Dentistry Shiraz University of Medical Sciences 2017-12 /pmc/articles/PMC5702434/ /pubmed/29201973 Text en Copyright: © Journal of Dentistry Shiraz University of Medical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Saboury, Abolfazl
Neshandar Asli, Hamid
Dalili Kajan, Zahra
The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap
title The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap
title_full The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap
title_fullStr The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap
title_full_unstemmed The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap
title_short The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap
title_sort accuracy of four impression-making techniques in angulated implants based on vertical gap
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5702434/
https://www.ncbi.nlm.nih.gov/pubmed/29201973
work_keys_str_mv AT sabouryabolfazl theaccuracyoffourimpressionmakingtechniquesinangulatedimplantsbasedonverticalgap
AT neshandaraslihamid theaccuracyoffourimpressionmakingtechniquesinangulatedimplantsbasedonverticalgap
AT dalilikajanzahra theaccuracyoffourimpressionmakingtechniquesinangulatedimplantsbasedonverticalgap
AT sabouryabolfazl accuracyoffourimpressionmakingtechniquesinangulatedimplantsbasedonverticalgap
AT neshandaraslihamid accuracyoffourimpressionmakingtechniquesinangulatedimplantsbasedonverticalgap
AT dalilikajanzahra accuracyoffourimpressionmakingtechniquesinangulatedimplantsbasedonverticalgap