Cargando…

The PhysioCam: A Novel Non-Contact Sensor to Measure Heart Rate Variability in Clinical and Field Applications

Heart rate variability (HRV) is a reliable indicator of health status and a sensitive index of autonomic stress reactivity. Stress negatively affects physical and psychological wellness by decreasing cardiovascular health and reducing quality of life. Wearable sensors have made it possible to track...

Descripción completa

Detalles Bibliográficos
Autores principales: Davila, Maria I., Lewis, Gregory F., Porges, Stephen W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5702637/
https://www.ncbi.nlm.nih.gov/pubmed/29214150
http://dx.doi.org/10.3389/fpubh.2017.00300
_version_ 1783281563744600064
author Davila, Maria I.
Lewis, Gregory F.
Porges, Stephen W.
author_facet Davila, Maria I.
Lewis, Gregory F.
Porges, Stephen W.
author_sort Davila, Maria I.
collection PubMed
description Heart rate variability (HRV) is a reliable indicator of health status and a sensitive index of autonomic stress reactivity. Stress negatively affects physical and psychological wellness by decreasing cardiovascular health and reducing quality of life. Wearable sensors have made it possible to track HRV during daily activity, and recent advances in mobile technology have reduced the cost and difficulty of applying this powerful technique. Although advances have made sensors smaller and lighter, some burden on the subject remains. Chest-worn electrocardiogram (ECG) sensors provide the optimal source signal for HRV analysis, but they require obtrusive electrode or conductive material adherence. A less invasive surrogate of HRV can be derived from the arterial pulse obtained using the photoplethysmogram (PPG), but sensor placement requirements limit the application of PPG in field research. Factors including gender, age, height, and weight also affect PPG-HRV level, but PPG-HRV is sufficient to track individual HRV reactions to physical and mental challenges. To overcome the limitations of contact sensors, we developed the PhysioCam (PhyC), a non-contact system capable of measuring arterial pulse with sufficient precision to derive HRV during different challenges. This passive sensor uses an off the shelf digital color video camera to extract arterial pulse from the light reflected from an individual’s face. In this article, we validate this novel non-contact measure against criterion signals (ECG and PPG) in a controlled laboratory setting. Data from 12 subjects are presented under the following physiological conditions: rest, single deep breath and hold, and rapid breathing. The following HRV parameters were validated: interbeat interval (IBI), respiratory sinus arrhythmia (RSA), and low frequency HRV (LF). When testing the PhyC against ECG or PPG: the Bland–Altman plots for the IBIs show no systematic bias; correlation coefficients (all p values < 0.05) comparing ECG to PhyC for IBI and LF approach 1, while RSA correlations average 0.82 across conditions. We discuss future refinements of the HRV metrics derived from the PhyC that will enable this technology to unobtrusively track indicators of health and wellness.
format Online
Article
Text
id pubmed-5702637
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-57026372017-12-06 The PhysioCam: A Novel Non-Contact Sensor to Measure Heart Rate Variability in Clinical and Field Applications Davila, Maria I. Lewis, Gregory F. Porges, Stephen W. Front Public Health Public Health Heart rate variability (HRV) is a reliable indicator of health status and a sensitive index of autonomic stress reactivity. Stress negatively affects physical and psychological wellness by decreasing cardiovascular health and reducing quality of life. Wearable sensors have made it possible to track HRV during daily activity, and recent advances in mobile technology have reduced the cost and difficulty of applying this powerful technique. Although advances have made sensors smaller and lighter, some burden on the subject remains. Chest-worn electrocardiogram (ECG) sensors provide the optimal source signal for HRV analysis, but they require obtrusive electrode or conductive material adherence. A less invasive surrogate of HRV can be derived from the arterial pulse obtained using the photoplethysmogram (PPG), but sensor placement requirements limit the application of PPG in field research. Factors including gender, age, height, and weight also affect PPG-HRV level, but PPG-HRV is sufficient to track individual HRV reactions to physical and mental challenges. To overcome the limitations of contact sensors, we developed the PhysioCam (PhyC), a non-contact system capable of measuring arterial pulse with sufficient precision to derive HRV during different challenges. This passive sensor uses an off the shelf digital color video camera to extract arterial pulse from the light reflected from an individual’s face. In this article, we validate this novel non-contact measure against criterion signals (ECG and PPG) in a controlled laboratory setting. Data from 12 subjects are presented under the following physiological conditions: rest, single deep breath and hold, and rapid breathing. The following HRV parameters were validated: interbeat interval (IBI), respiratory sinus arrhythmia (RSA), and low frequency HRV (LF). When testing the PhyC against ECG or PPG: the Bland–Altman plots for the IBIs show no systematic bias; correlation coefficients (all p values < 0.05) comparing ECG to PhyC for IBI and LF approach 1, while RSA correlations average 0.82 across conditions. We discuss future refinements of the HRV metrics derived from the PhyC that will enable this technology to unobtrusively track indicators of health and wellness. Frontiers Media S.A. 2017-11-22 /pmc/articles/PMC5702637/ /pubmed/29214150 http://dx.doi.org/10.3389/fpubh.2017.00300 Text en Copyright © 2017 Davila, Lewis and Porges. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Public Health
Davila, Maria I.
Lewis, Gregory F.
Porges, Stephen W.
The PhysioCam: A Novel Non-Contact Sensor to Measure Heart Rate Variability in Clinical and Field Applications
title The PhysioCam: A Novel Non-Contact Sensor to Measure Heart Rate Variability in Clinical and Field Applications
title_full The PhysioCam: A Novel Non-Contact Sensor to Measure Heart Rate Variability in Clinical and Field Applications
title_fullStr The PhysioCam: A Novel Non-Contact Sensor to Measure Heart Rate Variability in Clinical and Field Applications
title_full_unstemmed The PhysioCam: A Novel Non-Contact Sensor to Measure Heart Rate Variability in Clinical and Field Applications
title_short The PhysioCam: A Novel Non-Contact Sensor to Measure Heart Rate Variability in Clinical and Field Applications
title_sort physiocam: a novel non-contact sensor to measure heart rate variability in clinical and field applications
topic Public Health
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5702637/
https://www.ncbi.nlm.nih.gov/pubmed/29214150
http://dx.doi.org/10.3389/fpubh.2017.00300
work_keys_str_mv AT davilamariai thephysiocamanovelnoncontactsensortomeasureheartratevariabilityinclinicalandfieldapplications
AT lewisgregoryf thephysiocamanovelnoncontactsensortomeasureheartratevariabilityinclinicalandfieldapplications
AT porgesstephenw thephysiocamanovelnoncontactsensortomeasureheartratevariabilityinclinicalandfieldapplications
AT davilamariai physiocamanovelnoncontactsensortomeasureheartratevariabilityinclinicalandfieldapplications
AT lewisgregoryf physiocamanovelnoncontactsensortomeasureheartratevariabilityinclinicalandfieldapplications
AT porgesstephenw physiocamanovelnoncontactsensortomeasureheartratevariabilityinclinicalandfieldapplications