The optimum sevoflurane concentration for supraglottic airway device Blockbuster™ insertion with spontaneous breathing in obese patients: a prospective observational study

BACKGROUND: Airway management of the obese patient presenting for surgery is more likely to be a challenging problem. Supraglottic airway device has been adopted as a bridge to connect ventilation and tracheal intubation in obese patients who would be suffered with difficult intubation. The optimum...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Haixia, Gao, Xue, Wei, Wei, Miao, Huihui, Meng, Hua, Tian, Ming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5704385/
https://www.ncbi.nlm.nih.gov/pubmed/29179689
http://dx.doi.org/10.1186/s12871-017-0449-5
Descripción
Sumario:BACKGROUND: Airway management of the obese patient presenting for surgery is more likely to be a challenging problem. Supraglottic airway device has been adopted as a bridge to connect ventilation and tracheal intubation in obese patients who would be suffered with difficult intubation. The optimum sevoflurane concentration for supraglottic airway device insertion allowing spontaneous breathing in 50% of obese patients (ED(50)) is not known. The purpose of this study was to determine the ED(50) of sevoflurane for supraglottic airway device Blockbuster™ insertion with spontaneous breathing in obese patients requiring general anesthesia. METHODS: Thirty elective obese patients (body mass index 30-50 kg/m(2)) undergoing bariatric surgery were recruited in this study. The predetermined target sevoflurane concentration (initiating at 2.5% with 0.5% as a step size) was sustained for >5 min using a modified Dixon’s up-and-down method, and then the supraglottic airway device Blockbuster™ was inserted. The patient’s response to supraglottic airway device insertion was classified as either ‘movement’ or ‘no-movement’. The ED(50) of sevoflurane were determined by calculating the midpoint concentration of crossover point from ‘movement’ or ‘no-movement’ response. RESULTS: The ED(50) of sevoflurane for supraglottic airway device Blockbuster™ insertion in obese patients calculated using up-and-down method were 2.50 ± 0.60%. The ED(50) and ED(95) (95% confidence interval) obtained by probit regression analysis were 2.35 (1.28–3.42) % and 4.03 (3.16–17.83) % for supraglottic airway device Blockbuster™ insertion, respectively. CONCLUSION: We conclude that the optimum end-tidal sevoflurane concentration required for the supraglottic airway device Blockbuster™ insertion allowing spontaneous breathing in 50% of obese patients (ED(50)) is 2.5 ± 0.6%. TRIAL REGISTRATION: Chinese Clinical Trial Registry, ChiCTR-IPR-16009071, Registered on 24 August 2016.