Impact of robust treatment planning on single- and multi-field optimized plans for proton beam therapy of unilateral head and neck target volumes

BACKGROUND: Proton beam therapy is promising for the treatment of head and neck cancer (HNC), but it is sensitive to uncertainties in patient positioning and particle range. Studies have shown that the planning target volume (PTV) concept may not be sufficient to ensure robustness of the target cove...

Descripción completa

Detalles Bibliográficos
Autores principales: Cubillos-Mesías, Macarena, Baumann, Michael, Troost, Esther G. C., Lohaus, Fabian, Löck, Steffen, Richter, Christian, Stützer, Kristin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5706329/
https://www.ncbi.nlm.nih.gov/pubmed/29183377
http://dx.doi.org/10.1186/s13014-017-0931-8
_version_ 1783282209310900224
author Cubillos-Mesías, Macarena
Baumann, Michael
Troost, Esther G. C.
Lohaus, Fabian
Löck, Steffen
Richter, Christian
Stützer, Kristin
author_facet Cubillos-Mesías, Macarena
Baumann, Michael
Troost, Esther G. C.
Lohaus, Fabian
Löck, Steffen
Richter, Christian
Stützer, Kristin
author_sort Cubillos-Mesías, Macarena
collection PubMed
description BACKGROUND: Proton beam therapy is promising for the treatment of head and neck cancer (HNC), but it is sensitive to uncertainties in patient positioning and particle range. Studies have shown that the planning target volume (PTV) concept may not be sufficient to ensure robustness of the target coverage. A few planning studies have considered irradiation of unilateral HNC targets with protons, but they have only taken into account the dose on the nominal plan, without considering anatomy changes occurring during the treatment course. METHODS: Four pencil beam scanning (PBS) proton therapy plans were calculated for 8 HNC patients with unilateral target volumes: single-field (SFO) and multi-field optimized (MFO) plans, either using the PTV concept or clinical target volume (CTV)-based robust optimization. The dose was recalculated on computed tomography (CT) scans acquired during the treatment course. Doses to target volumes and organs at risk (OARs) were compared for the nominal plans, cumulative doses considering anatomical changes, and additional setup and range errors in each fraction. If required, the treatment plan was adapted, and the dose was compared with the non-adapted plan. RESULTS: All nominal plans fulfilled the clinical specifications for target coverage, but significantly higher doses on the ipsilateral parotid gland were found for both SFO approaches. MFO PTV-based plans had the lowest robustness against range and setup errors. During the treatment course, the influence of the anatomical variation on the dose has shown to be patient specific, mostly independent of the chosen planning approach. Nine plans in four patients required adaptation, which led to a significant improvement of the target coverage and a slight reduction in the OAR dose in comparison to the cumulative dose without adaptation. CONCLUSIONS: The use of robust MFO optimization is recommended for ensuring plan robustness and reduced doses in the ipsilateral parotid gland. Anatomical changes occurring during the treatment course might degrade the target coverage and increase the dose in the OARs, independent of the chosen planning approach. For some patients, a plan adaptation may be required. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13014-017-0931-8) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-5706329
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-57063292017-12-05 Impact of robust treatment planning on single- and multi-field optimized plans for proton beam therapy of unilateral head and neck target volumes Cubillos-Mesías, Macarena Baumann, Michael Troost, Esther G. C. Lohaus, Fabian Löck, Steffen Richter, Christian Stützer, Kristin Radiat Oncol Research BACKGROUND: Proton beam therapy is promising for the treatment of head and neck cancer (HNC), but it is sensitive to uncertainties in patient positioning and particle range. Studies have shown that the planning target volume (PTV) concept may not be sufficient to ensure robustness of the target coverage. A few planning studies have considered irradiation of unilateral HNC targets with protons, but they have only taken into account the dose on the nominal plan, without considering anatomy changes occurring during the treatment course. METHODS: Four pencil beam scanning (PBS) proton therapy plans were calculated for 8 HNC patients with unilateral target volumes: single-field (SFO) and multi-field optimized (MFO) plans, either using the PTV concept or clinical target volume (CTV)-based robust optimization. The dose was recalculated on computed tomography (CT) scans acquired during the treatment course. Doses to target volumes and organs at risk (OARs) were compared for the nominal plans, cumulative doses considering anatomical changes, and additional setup and range errors in each fraction. If required, the treatment plan was adapted, and the dose was compared with the non-adapted plan. RESULTS: All nominal plans fulfilled the clinical specifications for target coverage, but significantly higher doses on the ipsilateral parotid gland were found for both SFO approaches. MFO PTV-based plans had the lowest robustness against range and setup errors. During the treatment course, the influence of the anatomical variation on the dose has shown to be patient specific, mostly independent of the chosen planning approach. Nine plans in four patients required adaptation, which led to a significant improvement of the target coverage and a slight reduction in the OAR dose in comparison to the cumulative dose without adaptation. CONCLUSIONS: The use of robust MFO optimization is recommended for ensuring plan robustness and reduced doses in the ipsilateral parotid gland. Anatomical changes occurring during the treatment course might degrade the target coverage and increase the dose in the OARs, independent of the chosen planning approach. For some patients, a plan adaptation may be required. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13014-017-0931-8) contains supplementary material, which is available to authorized users. BioMed Central 2017-11-28 /pmc/articles/PMC5706329/ /pubmed/29183377 http://dx.doi.org/10.1186/s13014-017-0931-8 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Cubillos-Mesías, Macarena
Baumann, Michael
Troost, Esther G. C.
Lohaus, Fabian
Löck, Steffen
Richter, Christian
Stützer, Kristin
Impact of robust treatment planning on single- and multi-field optimized plans for proton beam therapy of unilateral head and neck target volumes
title Impact of robust treatment planning on single- and multi-field optimized plans for proton beam therapy of unilateral head and neck target volumes
title_full Impact of robust treatment planning on single- and multi-field optimized plans for proton beam therapy of unilateral head and neck target volumes
title_fullStr Impact of robust treatment planning on single- and multi-field optimized plans for proton beam therapy of unilateral head and neck target volumes
title_full_unstemmed Impact of robust treatment planning on single- and multi-field optimized plans for proton beam therapy of unilateral head and neck target volumes
title_short Impact of robust treatment planning on single- and multi-field optimized plans for proton beam therapy of unilateral head and neck target volumes
title_sort impact of robust treatment planning on single- and multi-field optimized plans for proton beam therapy of unilateral head and neck target volumes
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5706329/
https://www.ncbi.nlm.nih.gov/pubmed/29183377
http://dx.doi.org/10.1186/s13014-017-0931-8
work_keys_str_mv AT cubillosmesiasmacarena impactofrobusttreatmentplanningonsingleandmultifieldoptimizedplansforprotonbeamtherapyofunilateralheadandnecktargetvolumes
AT baumannmichael impactofrobusttreatmentplanningonsingleandmultifieldoptimizedplansforprotonbeamtherapyofunilateralheadandnecktargetvolumes
AT troostesthergc impactofrobusttreatmentplanningonsingleandmultifieldoptimizedplansforprotonbeamtherapyofunilateralheadandnecktargetvolumes
AT lohausfabian impactofrobusttreatmentplanningonsingleandmultifieldoptimizedplansforprotonbeamtherapyofunilateralheadandnecktargetvolumes
AT locksteffen impactofrobusttreatmentplanningonsingleandmultifieldoptimizedplansforprotonbeamtherapyofunilateralheadandnecktargetvolumes
AT richterchristian impactofrobusttreatmentplanningonsingleandmultifieldoptimizedplansforprotonbeamtherapyofunilateralheadandnecktargetvolumes
AT stutzerkristin impactofrobusttreatmentplanningonsingleandmultifieldoptimizedplansforprotonbeamtherapyofunilateralheadandnecktargetvolumes