RATIONALE: Among atrial fibrillation patients with high risk of bleeding, left atrial appendage occlusion has emerged as an alternative to long-term oral anticoagulation therapy for stroke prevention. Device-related thrombus remains a major concern because it may result in recurrent embolic events....
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5708950/ https://www.ncbi.nlm.nih.gov/pubmed/29381951 http://dx.doi.org/10.1097/MD.0000000000008693 |
_version_ | 1783282709330657280 |
---|---|
author | Wong, Chun-Ka Chan, Pak-Hei Lam, Cheung-Chi Kwok, On-Hing Lam, Yat-Yin Siu, Chung-Wah |
author_facet | Wong, Chun-Ka Chan, Pak-Hei Lam, Cheung-Chi Kwok, On-Hing Lam, Yat-Yin Siu, Chung-Wah |
author_sort | Wong, Chun-Ka |
collection | PubMed |
description | RATIONALE: Among atrial fibrillation patients with high risk of bleeding, left atrial appendage occlusion has emerged as an alternative to long-term oral anticoagulation therapy for stroke prevention. Device-related thrombus remains a major concern because it may result in recurrent embolic events. To date, there is no consensus on the optimal method of treating device-related-thrombus. PATIENT CONCERNS: A 78-year-old man with atrial fibrillation had an episode of intracranial hemorrhage while taking warfarin. He subsequently underwent percutaneous placement of a 30-mm Watchman device to the left atrial appendage. He was prescribed dual anti-platelet therapy with aspirin and clopidogrel. DIAGNOSIS: Reassessment echocardiography 3 months later found device-related thrombus. INTERVENTIONS: The antithrombotic regimen was switched from dual antiplatelet therapy to apixaban. OUTCOMES: Reassessment echocardiography 3 months later revealed complete resolution of the device-related thrombus. Apixaban was stopped. He had dual antiplatelet therapy for 6 more months followed by life-long aspirin. There was no bleeding complication since implantation of Watchman device. LESSONS: We demonstrated successful treatment of device-related thrombus with a short course of apixaban with complete resolution of thrombus. Further randomized controlled trials are required to determine the choice and duration of drug therapy for device-related thrombus. |
format | Online Article Text |
id | pubmed-5708950 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-57089502017-12-07 WATCHMAN device-related thrombus successfully treated with apixaban: A case report Wong, Chun-Ka Chan, Pak-Hei Lam, Cheung-Chi Kwok, On-Hing Lam, Yat-Yin Siu, Chung-Wah Medicine (Baltimore) 3400 RATIONALE: Among atrial fibrillation patients with high risk of bleeding, left atrial appendage occlusion has emerged as an alternative to long-term oral anticoagulation therapy for stroke prevention. Device-related thrombus remains a major concern because it may result in recurrent embolic events. To date, there is no consensus on the optimal method of treating device-related-thrombus. PATIENT CONCERNS: A 78-year-old man with atrial fibrillation had an episode of intracranial hemorrhage while taking warfarin. He subsequently underwent percutaneous placement of a 30-mm Watchman device to the left atrial appendage. He was prescribed dual anti-platelet therapy with aspirin and clopidogrel. DIAGNOSIS: Reassessment echocardiography 3 months later found device-related thrombus. INTERVENTIONS: The antithrombotic regimen was switched from dual antiplatelet therapy to apixaban. OUTCOMES: Reassessment echocardiography 3 months later revealed complete resolution of the device-related thrombus. Apixaban was stopped. He had dual antiplatelet therapy for 6 more months followed by life-long aspirin. There was no bleeding complication since implantation of Watchman device. LESSONS: We demonstrated successful treatment of device-related thrombus with a short course of apixaban with complete resolution of thrombus. Further randomized controlled trials are required to determine the choice and duration of drug therapy for device-related thrombus. Wolters Kluwer Health 2017-11-27 /pmc/articles/PMC5708950/ /pubmed/29381951 http://dx.doi.org/10.1097/MD.0000000000008693 Text en Copyright © 2017 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nd/4.0 This is an open access article distributed under the Creative Commons Attribution-NoDerivatives License 4.0, which allows for redistribution, commercial and non-commercial, as long as it is passed along unchanged and in whole, with credit to the author. http://creativecommons.org/licenses/by-nd/4.0 |
spellingShingle | 3400 Wong, Chun-Ka Chan, Pak-Hei Lam, Cheung-Chi Kwok, On-Hing Lam, Yat-Yin Siu, Chung-Wah WATCHMAN device-related thrombus successfully treated with apixaban: A case report |
title | WATCHMAN device-related thrombus successfully treated with apixaban: A case report |
title_full | WATCHMAN device-related thrombus successfully treated with apixaban: A case report |
title_fullStr | WATCHMAN device-related thrombus successfully treated with apixaban: A case report |
title_full_unstemmed | WATCHMAN device-related thrombus successfully treated with apixaban: A case report |
title_short | WATCHMAN device-related thrombus successfully treated with apixaban: A case report |
title_sort | watchman device-related thrombus successfully treated with apixaban: a case report |
topic | 3400 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5708950/ https://www.ncbi.nlm.nih.gov/pubmed/29381951 http://dx.doi.org/10.1097/MD.0000000000008693 |
work_keys_str_mv | AT wongchunka watchmandevicerelatedthrombussuccessfullytreatedwithapixabanacasereport AT chanpakhei watchmandevicerelatedthrombussuccessfullytreatedwithapixabanacasereport AT lamcheungchi watchmandevicerelatedthrombussuccessfullytreatedwithapixabanacasereport AT kwokonhing watchmandevicerelatedthrombussuccessfullytreatedwithapixabanacasereport AT lamyatyin watchmandevicerelatedthrombussuccessfullytreatedwithapixabanacasereport AT siuchungwah watchmandevicerelatedthrombussuccessfullytreatedwithapixabanacasereport |