Cargando…
Determination of velocity correction factors for real-time air velocity monitoring in underground mines
When there are installations of air velocity sensors in the mining industry for real-time airflow monitoring, a problem exists with how the monitored air velocity at a fixed location corresponds to the average air velocity, which is used to determine the volume flow rate of air in an entry with the...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5709814/ https://www.ncbi.nlm.nih.gov/pubmed/29201495 http://dx.doi.org/10.1007/s40789-017-0184-z |
_version_ | 1783282845421142016 |
---|---|
author | Zhou, Lihong Yuan, Liming Thomas, Rick Iannacchione, Anthony |
author_facet | Zhou, Lihong Yuan, Liming Thomas, Rick Iannacchione, Anthony |
author_sort | Zhou, Lihong |
collection | PubMed |
description | When there are installations of air velocity sensors in the mining industry for real-time airflow monitoring, a problem exists with how the monitored air velocity at a fixed location corresponds to the average air velocity, which is used to determine the volume flow rate of air in an entry with the cross-sectional area. Correction factors have been practically employed to convert a measured centerline air velocity to the average air velocity. However, studies on the recommended correction factors of the sensor-measured air velocity to the average air velocity at cross sections are still lacking. A comprehensive airflow measurement was made at the Safety Research Coal Mine, Bruceton, PA, using three measuring methods including single-point reading, moving traverse, and fixed-point traverse. The air velocity distribution at each measuring station was analyzed using an air velocity contour map generated with Surfer(®). The correction factors at each measuring station for both the centerline and the sensor location were calculated and are discussed. |
format | Online Article Text |
id | pubmed-5709814 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
record_format | MEDLINE/PubMed |
spelling | pubmed-57098142017-12-01 Determination of velocity correction factors for real-time air velocity monitoring in underground mines Zhou, Lihong Yuan, Liming Thomas, Rick Iannacchione, Anthony Int J Coal Sci Technol Article When there are installations of air velocity sensors in the mining industry for real-time airflow monitoring, a problem exists with how the monitored air velocity at a fixed location corresponds to the average air velocity, which is used to determine the volume flow rate of air in an entry with the cross-sectional area. Correction factors have been practically employed to convert a measured centerline air velocity to the average air velocity. However, studies on the recommended correction factors of the sensor-measured air velocity to the average air velocity at cross sections are still lacking. A comprehensive airflow measurement was made at the Safety Research Coal Mine, Bruceton, PA, using three measuring methods including single-point reading, moving traverse, and fixed-point traverse. The air velocity distribution at each measuring station was analyzed using an air velocity contour map generated with Surfer(®). The correction factors at each measuring station for both the centerline and the sensor location were calculated and are discussed. 2017-11-16 2017-12 /pmc/articles/PMC5709814/ /pubmed/29201495 http://dx.doi.org/10.1007/s40789-017-0184-z Text en This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Article Zhou, Lihong Yuan, Liming Thomas, Rick Iannacchione, Anthony Determination of velocity correction factors for real-time air velocity monitoring in underground mines |
title | Determination of velocity correction factors for real-time air velocity monitoring in underground mines |
title_full | Determination of velocity correction factors for real-time air velocity monitoring in underground mines |
title_fullStr | Determination of velocity correction factors for real-time air velocity monitoring in underground mines |
title_full_unstemmed | Determination of velocity correction factors for real-time air velocity monitoring in underground mines |
title_short | Determination of velocity correction factors for real-time air velocity monitoring in underground mines |
title_sort | determination of velocity correction factors for real-time air velocity monitoring in underground mines |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5709814/ https://www.ncbi.nlm.nih.gov/pubmed/29201495 http://dx.doi.org/10.1007/s40789-017-0184-z |
work_keys_str_mv | AT zhoulihong determinationofvelocitycorrectionfactorsforrealtimeairvelocitymonitoringinundergroundmines AT yuanliming determinationofvelocitycorrectionfactorsforrealtimeairvelocitymonitoringinundergroundmines AT thomasrick determinationofvelocitycorrectionfactorsforrealtimeairvelocitymonitoringinundergroundmines AT iannacchioneanthony determinationofvelocitycorrectionfactorsforrealtimeairvelocitymonitoringinundergroundmines |