Cargando…

Determination of velocity correction factors for real-time air velocity monitoring in underground mines

When there are installations of air velocity sensors in the mining industry for real-time airflow monitoring, a problem exists with how the monitored air velocity at a fixed location corresponds to the average air velocity, which is used to determine the volume flow rate of air in an entry with the...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Lihong, Yuan, Liming, Thomas, Rick, Iannacchione, Anthony
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5709814/
https://www.ncbi.nlm.nih.gov/pubmed/29201495
http://dx.doi.org/10.1007/s40789-017-0184-z
_version_ 1783282845421142016
author Zhou, Lihong
Yuan, Liming
Thomas, Rick
Iannacchione, Anthony
author_facet Zhou, Lihong
Yuan, Liming
Thomas, Rick
Iannacchione, Anthony
author_sort Zhou, Lihong
collection PubMed
description When there are installations of air velocity sensors in the mining industry for real-time airflow monitoring, a problem exists with how the monitored air velocity at a fixed location corresponds to the average air velocity, which is used to determine the volume flow rate of air in an entry with the cross-sectional area. Correction factors have been practically employed to convert a measured centerline air velocity to the average air velocity. However, studies on the recommended correction factors of the sensor-measured air velocity to the average air velocity at cross sections are still lacking. A comprehensive airflow measurement was made at the Safety Research Coal Mine, Bruceton, PA, using three measuring methods including single-point reading, moving traverse, and fixed-point traverse. The air velocity distribution at each measuring station was analyzed using an air velocity contour map generated with Surfer(®). The correction factors at each measuring station for both the centerline and the sensor location were calculated and are discussed.
format Online
Article
Text
id pubmed-5709814
institution National Center for Biotechnology Information
language English
publishDate 2017
record_format MEDLINE/PubMed
spelling pubmed-57098142017-12-01 Determination of velocity correction factors for real-time air velocity monitoring in underground mines Zhou, Lihong Yuan, Liming Thomas, Rick Iannacchione, Anthony Int J Coal Sci Technol Article When there are installations of air velocity sensors in the mining industry for real-time airflow monitoring, a problem exists with how the monitored air velocity at a fixed location corresponds to the average air velocity, which is used to determine the volume flow rate of air in an entry with the cross-sectional area. Correction factors have been practically employed to convert a measured centerline air velocity to the average air velocity. However, studies on the recommended correction factors of the sensor-measured air velocity to the average air velocity at cross sections are still lacking. A comprehensive airflow measurement was made at the Safety Research Coal Mine, Bruceton, PA, using three measuring methods including single-point reading, moving traverse, and fixed-point traverse. The air velocity distribution at each measuring station was analyzed using an air velocity contour map generated with Surfer(®). The correction factors at each measuring station for both the centerline and the sensor location were calculated and are discussed. 2017-11-16 2017-12 /pmc/articles/PMC5709814/ /pubmed/29201495 http://dx.doi.org/10.1007/s40789-017-0184-z Text en This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Article
Zhou, Lihong
Yuan, Liming
Thomas, Rick
Iannacchione, Anthony
Determination of velocity correction factors for real-time air velocity monitoring in underground mines
title Determination of velocity correction factors for real-time air velocity monitoring in underground mines
title_full Determination of velocity correction factors for real-time air velocity monitoring in underground mines
title_fullStr Determination of velocity correction factors for real-time air velocity monitoring in underground mines
title_full_unstemmed Determination of velocity correction factors for real-time air velocity monitoring in underground mines
title_short Determination of velocity correction factors for real-time air velocity monitoring in underground mines
title_sort determination of velocity correction factors for real-time air velocity monitoring in underground mines
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5709814/
https://www.ncbi.nlm.nih.gov/pubmed/29201495
http://dx.doi.org/10.1007/s40789-017-0184-z
work_keys_str_mv AT zhoulihong determinationofvelocitycorrectionfactorsforrealtimeairvelocitymonitoringinundergroundmines
AT yuanliming determinationofvelocitycorrectionfactorsforrealtimeairvelocitymonitoringinundergroundmines
AT thomasrick determinationofvelocitycorrectionfactorsforrealtimeairvelocitymonitoringinundergroundmines
AT iannacchioneanthony determinationofvelocitycorrectionfactorsforrealtimeairvelocitymonitoringinundergroundmines