Cargando…

Flow-diverting Stent-assisted Coil Embolization of a Ruptured Internal Carotid Artery Blister Aneurysm with the Pipeline Flex Embolization Device

Internal carotid artery (ICA) blister aneurysms are rare and challenging to successfully treat, using contemporary surgical or endovascular approaches, without partial or complete compromise of the parent vessel. We describe the use of a resheathable flow diverter, the Pipeline Flex Embolization Dev...

Descripción completa

Detalles Bibliográficos
Autores principales: Ding, Dale, Starke, Robert M., Hope, Ayton, Brew, Stefan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5709899/
https://www.ncbi.nlm.nih.gov/pubmed/29204036
http://dx.doi.org/10.4103/jnrp.jnrp_336_17
_version_ 1783282867625787392
author Ding, Dale
Starke, Robert M.
Hope, Ayton
Brew, Stefan
author_facet Ding, Dale
Starke, Robert M.
Hope, Ayton
Brew, Stefan
author_sort Ding, Dale
collection PubMed
description Internal carotid artery (ICA) blister aneurysms are rare and challenging to successfully treat, using contemporary surgical or endovascular approaches, without partial or complete compromise of the parent vessel. We describe the use of a resheathable flow diverter, the Pipeline Flex Embolization Device (PFED) to perform stent-assisted coiling of a ruptured supraclinoid ICA blister aneurysm in a 56-year-old female who presented with a high-grade subarachnoid hemorrhage (SAH). The first PFED was deployed across the aneurysm neck to jail a microcatheter within the aneurysm dome, and then, two small coils were delivered into the aneurysm. After removing the coiling microcatheter, the second PFED was telescoped into the first PFED. There were no postprocedural complications, and follow-up magnetic resonance angiography 15 months after embolization showed complete aneurysm obliteration. Flow-diverting stent-assisted coiling should be considered as a reconstructive, vessel-preserving, endovascular treatment option for appropriately selected patients with ruptured ICA blister aneurysms. However, future studies are necessary to assess the periprocedural safety in the setting of acute SAH.
format Online
Article
Text
id pubmed-5709899
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-57098992017-12-04 Flow-diverting Stent-assisted Coil Embolization of a Ruptured Internal Carotid Artery Blister Aneurysm with the Pipeline Flex Embolization Device Ding, Dale Starke, Robert M. Hope, Ayton Brew, Stefan J Neurosci Rural Pract Case Report Internal carotid artery (ICA) blister aneurysms are rare and challenging to successfully treat, using contemporary surgical or endovascular approaches, without partial or complete compromise of the parent vessel. We describe the use of a resheathable flow diverter, the Pipeline Flex Embolization Device (PFED) to perform stent-assisted coiling of a ruptured supraclinoid ICA blister aneurysm in a 56-year-old female who presented with a high-grade subarachnoid hemorrhage (SAH). The first PFED was deployed across the aneurysm neck to jail a microcatheter within the aneurysm dome, and then, two small coils were delivered into the aneurysm. After removing the coiling microcatheter, the second PFED was telescoped into the first PFED. There were no postprocedural complications, and follow-up magnetic resonance angiography 15 months after embolization showed complete aneurysm obliteration. Flow-diverting stent-assisted coiling should be considered as a reconstructive, vessel-preserving, endovascular treatment option for appropriately selected patients with ruptured ICA blister aneurysms. However, future studies are necessary to assess the periprocedural safety in the setting of acute SAH. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5709899/ /pubmed/29204036 http://dx.doi.org/10.4103/jnrp.jnrp_336_17 Text en Copyright: © 2017 Journal of Neurosciences in Rural Practice http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Case Report
Ding, Dale
Starke, Robert M.
Hope, Ayton
Brew, Stefan
Flow-diverting Stent-assisted Coil Embolization of a Ruptured Internal Carotid Artery Blister Aneurysm with the Pipeline Flex Embolization Device
title Flow-diverting Stent-assisted Coil Embolization of a Ruptured Internal Carotid Artery Blister Aneurysm with the Pipeline Flex Embolization Device
title_full Flow-diverting Stent-assisted Coil Embolization of a Ruptured Internal Carotid Artery Blister Aneurysm with the Pipeline Flex Embolization Device
title_fullStr Flow-diverting Stent-assisted Coil Embolization of a Ruptured Internal Carotid Artery Blister Aneurysm with the Pipeline Flex Embolization Device
title_full_unstemmed Flow-diverting Stent-assisted Coil Embolization of a Ruptured Internal Carotid Artery Blister Aneurysm with the Pipeline Flex Embolization Device
title_short Flow-diverting Stent-assisted Coil Embolization of a Ruptured Internal Carotid Artery Blister Aneurysm with the Pipeline Flex Embolization Device
title_sort flow-diverting stent-assisted coil embolization of a ruptured internal carotid artery blister aneurysm with the pipeline flex embolization device
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5709899/
https://www.ncbi.nlm.nih.gov/pubmed/29204036
http://dx.doi.org/10.4103/jnrp.jnrp_336_17
work_keys_str_mv AT dingdale flowdivertingstentassistedcoilembolizationofarupturedinternalcarotidarteryblisteraneurysmwiththepipelineflexembolizationdevice
AT starkerobertm flowdivertingstentassistedcoilembolizationofarupturedinternalcarotidarteryblisteraneurysmwiththepipelineflexembolizationdevice
AT hopeayton flowdivertingstentassistedcoilembolizationofarupturedinternalcarotidarteryblisteraneurysmwiththepipelineflexembolizationdevice
AT brewstefan flowdivertingstentassistedcoilembolizationofarupturedinternalcarotidarteryblisteraneurysmwiththepipelineflexembolizationdevice