Cargando…
Flow-diverting Stent-assisted Coil Embolization of a Ruptured Internal Carotid Artery Blister Aneurysm with the Pipeline Flex Embolization Device
Internal carotid artery (ICA) blister aneurysms are rare and challenging to successfully treat, using contemporary surgical or endovascular approaches, without partial or complete compromise of the parent vessel. We describe the use of a resheathable flow diverter, the Pipeline Flex Embolization Dev...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5709899/ https://www.ncbi.nlm.nih.gov/pubmed/29204036 http://dx.doi.org/10.4103/jnrp.jnrp_336_17 |
_version_ | 1783282867625787392 |
---|---|
author | Ding, Dale Starke, Robert M. Hope, Ayton Brew, Stefan |
author_facet | Ding, Dale Starke, Robert M. Hope, Ayton Brew, Stefan |
author_sort | Ding, Dale |
collection | PubMed |
description | Internal carotid artery (ICA) blister aneurysms are rare and challenging to successfully treat, using contemporary surgical or endovascular approaches, without partial or complete compromise of the parent vessel. We describe the use of a resheathable flow diverter, the Pipeline Flex Embolization Device (PFED) to perform stent-assisted coiling of a ruptured supraclinoid ICA blister aneurysm in a 56-year-old female who presented with a high-grade subarachnoid hemorrhage (SAH). The first PFED was deployed across the aneurysm neck to jail a microcatheter within the aneurysm dome, and then, two small coils were delivered into the aneurysm. After removing the coiling microcatheter, the second PFED was telescoped into the first PFED. There were no postprocedural complications, and follow-up magnetic resonance angiography 15 months after embolization showed complete aneurysm obliteration. Flow-diverting stent-assisted coiling should be considered as a reconstructive, vessel-preserving, endovascular treatment option for appropriately selected patients with ruptured ICA blister aneurysms. However, future studies are necessary to assess the periprocedural safety in the setting of acute SAH. |
format | Online Article Text |
id | pubmed-5709899 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-57098992017-12-04 Flow-diverting Stent-assisted Coil Embolization of a Ruptured Internal Carotid Artery Blister Aneurysm with the Pipeline Flex Embolization Device Ding, Dale Starke, Robert M. Hope, Ayton Brew, Stefan J Neurosci Rural Pract Case Report Internal carotid artery (ICA) blister aneurysms are rare and challenging to successfully treat, using contemporary surgical or endovascular approaches, without partial or complete compromise of the parent vessel. We describe the use of a resheathable flow diverter, the Pipeline Flex Embolization Device (PFED) to perform stent-assisted coiling of a ruptured supraclinoid ICA blister aneurysm in a 56-year-old female who presented with a high-grade subarachnoid hemorrhage (SAH). The first PFED was deployed across the aneurysm neck to jail a microcatheter within the aneurysm dome, and then, two small coils were delivered into the aneurysm. After removing the coiling microcatheter, the second PFED was telescoped into the first PFED. There were no postprocedural complications, and follow-up magnetic resonance angiography 15 months after embolization showed complete aneurysm obliteration. Flow-diverting stent-assisted coiling should be considered as a reconstructive, vessel-preserving, endovascular treatment option for appropriately selected patients with ruptured ICA blister aneurysms. However, future studies are necessary to assess the periprocedural safety in the setting of acute SAH. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5709899/ /pubmed/29204036 http://dx.doi.org/10.4103/jnrp.jnrp_336_17 Text en Copyright: © 2017 Journal of Neurosciences in Rural Practice http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Case Report Ding, Dale Starke, Robert M. Hope, Ayton Brew, Stefan Flow-diverting Stent-assisted Coil Embolization of a Ruptured Internal Carotid Artery Blister Aneurysm with the Pipeline Flex Embolization Device |
title | Flow-diverting Stent-assisted Coil Embolization of a Ruptured Internal Carotid Artery Blister Aneurysm with the Pipeline Flex Embolization Device |
title_full | Flow-diverting Stent-assisted Coil Embolization of a Ruptured Internal Carotid Artery Blister Aneurysm with the Pipeline Flex Embolization Device |
title_fullStr | Flow-diverting Stent-assisted Coil Embolization of a Ruptured Internal Carotid Artery Blister Aneurysm with the Pipeline Flex Embolization Device |
title_full_unstemmed | Flow-diverting Stent-assisted Coil Embolization of a Ruptured Internal Carotid Artery Blister Aneurysm with the Pipeline Flex Embolization Device |
title_short | Flow-diverting Stent-assisted Coil Embolization of a Ruptured Internal Carotid Artery Blister Aneurysm with the Pipeline Flex Embolization Device |
title_sort | flow-diverting stent-assisted coil embolization of a ruptured internal carotid artery blister aneurysm with the pipeline flex embolization device |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5709899/ https://www.ncbi.nlm.nih.gov/pubmed/29204036 http://dx.doi.org/10.4103/jnrp.jnrp_336_17 |
work_keys_str_mv | AT dingdale flowdivertingstentassistedcoilembolizationofarupturedinternalcarotidarteryblisteraneurysmwiththepipelineflexembolizationdevice AT starkerobertm flowdivertingstentassistedcoilembolizationofarupturedinternalcarotidarteryblisteraneurysmwiththepipelineflexembolizationdevice AT hopeayton flowdivertingstentassistedcoilembolizationofarupturedinternalcarotidarteryblisteraneurysmwiththepipelineflexembolizationdevice AT brewstefan flowdivertingstentassistedcoilembolizationofarupturedinternalcarotidarteryblisteraneurysmwiththepipelineflexembolizationdevice |