Cargando…

Is Laser Assisted Capsulotomy better than standard CCC?

Objectives: To compare the safety and intraoperative difficulties of two capsulorhexis techniques for white intumescent cataract: Femtolaser-assisted capsulorhexis and manual capsulorhexis performed in 2-3 stages, with the Utrata forceps. Materials and methods: A prospective comparative study that i...

Descripción completa

Detalles Bibliográficos
Autores principales: Gavriș, Monica, Mateescu, Radu, Belicioiu, Roxana, Olteanu, Ioana
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Romanian Society of Ophthalmology 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5710047/
https://www.ncbi.nlm.nih.gov/pubmed/29450366
_version_ 1783282903773347840
author Gavriș, Monica
Mateescu, Radu
Belicioiu, Roxana
Olteanu, Ioana
author_facet Gavriș, Monica
Mateescu, Radu
Belicioiu, Roxana
Olteanu, Ioana
author_sort Gavriș, Monica
collection PubMed
description Objectives: To compare the safety and intraoperative difficulties of two capsulorhexis techniques for white intumescent cataract: Femtolaser-assisted capsulorhexis and manual capsulorhexis performed in 2-3 stages, with the Utrata forceps. Materials and methods: A prospective comparative study that included 28 eyes divided into 2 equal groups in which capsulorhexis was performed by using the 2 methods. In the first group, the capsulorhexis was executed by using LenSx Femtolaser. In the second group, an Utrata forceps was used to perform a manual 2-3 steps capsulorhexis as follows: a small 2-3 mm capsulorhexis was performed after the staining of the anterior capsule with Trypan Blue along with a good pressurization with viscoelastic substance. The liquefied cortex was aspirated, followed by the enlargement of the capsulorhexis. In some cases, the enlargement was made after IOL implantation. Results: In the Femtolaser group, the capsule was completely detached in 13 cases and only in one case, the capsule had a few bridges which detached easily, without endangering the capsulorhexis integrity. Its size was 4,9 mm in all cases. In the group in which capsulorhexis was performed with the Utrata forceps in 2-3 stages, this was complete, circular and relatively well centered in all cases, but the size varied between 4,5 and 5,5 mm. Conclusions: Femtosecond laser-assisted capsulorhexis was round, well centered and of a desired size of 4,9 mm. The manual capsulorhexis with the Utrata forceps depends on the surgeon’s skill and experience and requires a good local anesthesia, the coloring of the anterior capsule with Tripan Blue, using a large quantity of cohesive viscoelastic substances and sometimes using micro incision forceps for helpful maneuvers. The size and centering of the capsulorhexis are not always identical with the intended ones.
format Online
Article
Text
id pubmed-5710047
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Romanian Society of Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-57100472017-12-14 Is Laser Assisted Capsulotomy better than standard CCC? Gavriș, Monica Mateescu, Radu Belicioiu, Roxana Olteanu, Ioana Rom J Ophthalmol General Articles Objectives: To compare the safety and intraoperative difficulties of two capsulorhexis techniques for white intumescent cataract: Femtolaser-assisted capsulorhexis and manual capsulorhexis performed in 2-3 stages, with the Utrata forceps. Materials and methods: A prospective comparative study that included 28 eyes divided into 2 equal groups in which capsulorhexis was performed by using the 2 methods. In the first group, the capsulorhexis was executed by using LenSx Femtolaser. In the second group, an Utrata forceps was used to perform a manual 2-3 steps capsulorhexis as follows: a small 2-3 mm capsulorhexis was performed after the staining of the anterior capsule with Trypan Blue along with a good pressurization with viscoelastic substance. The liquefied cortex was aspirated, followed by the enlargement of the capsulorhexis. In some cases, the enlargement was made after IOL implantation. Results: In the Femtolaser group, the capsule was completely detached in 13 cases and only in one case, the capsule had a few bridges which detached easily, without endangering the capsulorhexis integrity. Its size was 4,9 mm in all cases. In the group in which capsulorhexis was performed with the Utrata forceps in 2-3 stages, this was complete, circular and relatively well centered in all cases, but the size varied between 4,5 and 5,5 mm. Conclusions: Femtosecond laser-assisted capsulorhexis was round, well centered and of a desired size of 4,9 mm. The manual capsulorhexis with the Utrata forceps depends on the surgeon’s skill and experience and requires a good local anesthesia, the coloring of the anterior capsule with Tripan Blue, using a large quantity of cohesive viscoelastic substances and sometimes using micro incision forceps for helpful maneuvers. The size and centering of the capsulorhexis are not always identical with the intended ones. Romanian Society of Ophthalmology 2017 /pmc/articles/PMC5710047/ /pubmed/29450366 Text en ©Romanian Society of Ophthalmology http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle General Articles
Gavriș, Monica
Mateescu, Radu
Belicioiu, Roxana
Olteanu, Ioana
Is Laser Assisted Capsulotomy better than standard CCC?
title Is Laser Assisted Capsulotomy better than standard CCC?
title_full Is Laser Assisted Capsulotomy better than standard CCC?
title_fullStr Is Laser Assisted Capsulotomy better than standard CCC?
title_full_unstemmed Is Laser Assisted Capsulotomy better than standard CCC?
title_short Is Laser Assisted Capsulotomy better than standard CCC?
title_sort is laser assisted capsulotomy better than standard ccc?
topic General Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5710047/
https://www.ncbi.nlm.nih.gov/pubmed/29450366
work_keys_str_mv AT gavrismonica islaserassistedcapsulotomybetterthanstandardccc
AT mateescuradu islaserassistedcapsulotomybetterthanstandardccc
AT belicioiuroxana islaserassistedcapsulotomybetterthanstandardccc
AT olteanuioana islaserassistedcapsulotomybetterthanstandardccc