Cargando…

Quantitative assessment by measurement and modeling of mobile target elongation in cone‐beam computed tomographic imaging

The purpose of this study was to assess quantitatively elongation of mobile targets in cone‐beam CT (CBCT) imaging by measurement and modeling. A mathematical model was derived that predicts the measured lengths of mobile targets and its dependence on target size and motion patterns in CBCT imaging....

Descripción completa

Detalles Bibliográficos
Autores principales: Ali, Imad, Alsbou, Nesreen, Algan, Ozer, Herman, Terence, Ahmad, Salahuddin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5711045/
https://www.ncbi.nlm.nih.gov/pubmed/24892334
http://dx.doi.org/10.1120/jacmp.v15i3.4634
_version_ 1783282996227342336
author Ali, Imad
Alsbou, Nesreen
Algan, Ozer
Herman, Terence
Ahmad, Salahuddin
author_facet Ali, Imad
Alsbou, Nesreen
Algan, Ozer
Herman, Terence
Ahmad, Salahuddin
author_sort Ali, Imad
collection PubMed
description The purpose of this study was to assess quantitatively elongation of mobile targets in cone‐beam CT (CBCT) imaging by measurement and modeling. A mathematical model was derived that predicts the measured lengths of mobile targets and its dependence on target size and motion patterns in CBCT imaging. Three tissue‐equivalent targets of differing sizes were inserted in an artificial thorax phantom to simulate lung lesions. Respiratory motion was mimicked with a mobile phantom that moves in one‐dimension along the superior‐inferior direction at a respiration frequency of 0.24 Hz for eight different amplitudes in the range 0‐40 mm. A mathematical model was derived to quantify the variations in target lengths and its dependence on phantom motion parameters in CBCT. Predictions of the model were verified by measurement of the lengths of mobile targets in CBCT images. The model predicts that target lengths increased linearly with increase in speed and amplitude of phantom motion in CBCT. The measured lengths of mobile targets imaged with CBCT agreed with the calculated lengths within half‐slice thickness spatial resolution. The maximal length of a mobile target was independent of the frequency and phase of motion. Elongation of mobile targets was similar in halffan and full‐fan CBCT for similar motion patterns, as long as the targets remained within the imaging view. Mobile targets elongated linearly with phantom speed and motion amplitude in CBCT imaging. The model introduced in this work assessed quantitatively the variation in target lengths induced by motion, which may be a useful tool to consider elongations of mobile targets in CBCT applications in diagnostic imaging and radiotherapy. PACS number: 87.57.qp
format Online
Article
Text
id pubmed-5711045
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57110452018-04-02 Quantitative assessment by measurement and modeling of mobile target elongation in cone‐beam computed tomographic imaging Ali, Imad Alsbou, Nesreen Algan, Ozer Herman, Terence Ahmad, Salahuddin J Appl Clin Med Phys Medical Imaging The purpose of this study was to assess quantitatively elongation of mobile targets in cone‐beam CT (CBCT) imaging by measurement and modeling. A mathematical model was derived that predicts the measured lengths of mobile targets and its dependence on target size and motion patterns in CBCT imaging. Three tissue‐equivalent targets of differing sizes were inserted in an artificial thorax phantom to simulate lung lesions. Respiratory motion was mimicked with a mobile phantom that moves in one‐dimension along the superior‐inferior direction at a respiration frequency of 0.24 Hz for eight different amplitudes in the range 0‐40 mm. A mathematical model was derived to quantify the variations in target lengths and its dependence on phantom motion parameters in CBCT. Predictions of the model were verified by measurement of the lengths of mobile targets in CBCT images. The model predicts that target lengths increased linearly with increase in speed and amplitude of phantom motion in CBCT. The measured lengths of mobile targets imaged with CBCT agreed with the calculated lengths within half‐slice thickness spatial resolution. The maximal length of a mobile target was independent of the frequency and phase of motion. Elongation of mobile targets was similar in halffan and full‐fan CBCT for similar motion patterns, as long as the targets remained within the imaging view. Mobile targets elongated linearly with phantom speed and motion amplitude in CBCT imaging. The model introduced in this work assessed quantitatively the variation in target lengths induced by motion, which may be a useful tool to consider elongations of mobile targets in CBCT applications in diagnostic imaging and radiotherapy. PACS number: 87.57.qp John Wiley and Sons Inc. 2014-05-08 /pmc/articles/PMC5711045/ /pubmed/24892334 http://dx.doi.org/10.1120/jacmp.v15i3.4634 Text en © 2014 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Medical Imaging
Ali, Imad
Alsbou, Nesreen
Algan, Ozer
Herman, Terence
Ahmad, Salahuddin
Quantitative assessment by measurement and modeling of mobile target elongation in cone‐beam computed tomographic imaging
title Quantitative assessment by measurement and modeling of mobile target elongation in cone‐beam computed tomographic imaging
title_full Quantitative assessment by measurement and modeling of mobile target elongation in cone‐beam computed tomographic imaging
title_fullStr Quantitative assessment by measurement and modeling of mobile target elongation in cone‐beam computed tomographic imaging
title_full_unstemmed Quantitative assessment by measurement and modeling of mobile target elongation in cone‐beam computed tomographic imaging
title_short Quantitative assessment by measurement and modeling of mobile target elongation in cone‐beam computed tomographic imaging
title_sort quantitative assessment by measurement and modeling of mobile target elongation in cone‐beam computed tomographic imaging
topic Medical Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5711045/
https://www.ncbi.nlm.nih.gov/pubmed/24892334
http://dx.doi.org/10.1120/jacmp.v15i3.4634
work_keys_str_mv AT aliimad quantitativeassessmentbymeasurementandmodelingofmobiletargetelongationinconebeamcomputedtomographicimaging
AT alsbounesreen quantitativeassessmentbymeasurementandmodelingofmobiletargetelongationinconebeamcomputedtomographicimaging
AT alganozer quantitativeassessmentbymeasurementandmodelingofmobiletargetelongationinconebeamcomputedtomographicimaging
AT hermanterence quantitativeassessmentbymeasurementandmodelingofmobiletargetelongationinconebeamcomputedtomographicimaging
AT ahmadsalahuddin quantitativeassessmentbymeasurementandmodelingofmobiletargetelongationinconebeamcomputedtomographicimaging