Cargando…
Quantitative assessment by measurement and modeling of mobile target elongation in cone‐beam computed tomographic imaging
The purpose of this study was to assess quantitatively elongation of mobile targets in cone‐beam CT (CBCT) imaging by measurement and modeling. A mathematical model was derived that predicts the measured lengths of mobile targets and its dependence on target size and motion patterns in CBCT imaging....
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5711045/ https://www.ncbi.nlm.nih.gov/pubmed/24892334 http://dx.doi.org/10.1120/jacmp.v15i3.4634 |
_version_ | 1783282996227342336 |
---|---|
author | Ali, Imad Alsbou, Nesreen Algan, Ozer Herman, Terence Ahmad, Salahuddin |
author_facet | Ali, Imad Alsbou, Nesreen Algan, Ozer Herman, Terence Ahmad, Salahuddin |
author_sort | Ali, Imad |
collection | PubMed |
description | The purpose of this study was to assess quantitatively elongation of mobile targets in cone‐beam CT (CBCT) imaging by measurement and modeling. A mathematical model was derived that predicts the measured lengths of mobile targets and its dependence on target size and motion patterns in CBCT imaging. Three tissue‐equivalent targets of differing sizes were inserted in an artificial thorax phantom to simulate lung lesions. Respiratory motion was mimicked with a mobile phantom that moves in one‐dimension along the superior‐inferior direction at a respiration frequency of 0.24 Hz for eight different amplitudes in the range 0‐40 mm. A mathematical model was derived to quantify the variations in target lengths and its dependence on phantom motion parameters in CBCT. Predictions of the model were verified by measurement of the lengths of mobile targets in CBCT images. The model predicts that target lengths increased linearly with increase in speed and amplitude of phantom motion in CBCT. The measured lengths of mobile targets imaged with CBCT agreed with the calculated lengths within half‐slice thickness spatial resolution. The maximal length of a mobile target was independent of the frequency and phase of motion. Elongation of mobile targets was similar in halffan and full‐fan CBCT for similar motion patterns, as long as the targets remained within the imaging view. Mobile targets elongated linearly with phantom speed and motion amplitude in CBCT imaging. The model introduced in this work assessed quantitatively the variation in target lengths induced by motion, which may be a useful tool to consider elongations of mobile targets in CBCT applications in diagnostic imaging and radiotherapy. PACS number: 87.57.qp |
format | Online Article Text |
id | pubmed-5711045 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-57110452018-04-02 Quantitative assessment by measurement and modeling of mobile target elongation in cone‐beam computed tomographic imaging Ali, Imad Alsbou, Nesreen Algan, Ozer Herman, Terence Ahmad, Salahuddin J Appl Clin Med Phys Medical Imaging The purpose of this study was to assess quantitatively elongation of mobile targets in cone‐beam CT (CBCT) imaging by measurement and modeling. A mathematical model was derived that predicts the measured lengths of mobile targets and its dependence on target size and motion patterns in CBCT imaging. Three tissue‐equivalent targets of differing sizes were inserted in an artificial thorax phantom to simulate lung lesions. Respiratory motion was mimicked with a mobile phantom that moves in one‐dimension along the superior‐inferior direction at a respiration frequency of 0.24 Hz for eight different amplitudes in the range 0‐40 mm. A mathematical model was derived to quantify the variations in target lengths and its dependence on phantom motion parameters in CBCT. Predictions of the model were verified by measurement of the lengths of mobile targets in CBCT images. The model predicts that target lengths increased linearly with increase in speed and amplitude of phantom motion in CBCT. The measured lengths of mobile targets imaged with CBCT agreed with the calculated lengths within half‐slice thickness spatial resolution. The maximal length of a mobile target was independent of the frequency and phase of motion. Elongation of mobile targets was similar in halffan and full‐fan CBCT for similar motion patterns, as long as the targets remained within the imaging view. Mobile targets elongated linearly with phantom speed and motion amplitude in CBCT imaging. The model introduced in this work assessed quantitatively the variation in target lengths induced by motion, which may be a useful tool to consider elongations of mobile targets in CBCT applications in diagnostic imaging and radiotherapy. PACS number: 87.57.qp John Wiley and Sons Inc. 2014-05-08 /pmc/articles/PMC5711045/ /pubmed/24892334 http://dx.doi.org/10.1120/jacmp.v15i3.4634 Text en © 2014 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Medical Imaging Ali, Imad Alsbou, Nesreen Algan, Ozer Herman, Terence Ahmad, Salahuddin Quantitative assessment by measurement and modeling of mobile target elongation in cone‐beam computed tomographic imaging |
title | Quantitative assessment by measurement and modeling of mobile target elongation in cone‐beam computed tomographic imaging |
title_full | Quantitative assessment by measurement and modeling of mobile target elongation in cone‐beam computed tomographic imaging |
title_fullStr | Quantitative assessment by measurement and modeling of mobile target elongation in cone‐beam computed tomographic imaging |
title_full_unstemmed | Quantitative assessment by measurement and modeling of mobile target elongation in cone‐beam computed tomographic imaging |
title_short | Quantitative assessment by measurement and modeling of mobile target elongation in cone‐beam computed tomographic imaging |
title_sort | quantitative assessment by measurement and modeling of mobile target elongation in cone‐beam computed tomographic imaging |
topic | Medical Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5711045/ https://www.ncbi.nlm.nih.gov/pubmed/24892334 http://dx.doi.org/10.1120/jacmp.v15i3.4634 |
work_keys_str_mv | AT aliimad quantitativeassessmentbymeasurementandmodelingofmobiletargetelongationinconebeamcomputedtomographicimaging AT alsbounesreen quantitativeassessmentbymeasurementandmodelingofmobiletargetelongationinconebeamcomputedtomographicimaging AT alganozer quantitativeassessmentbymeasurementandmodelingofmobiletargetelongationinconebeamcomputedtomographicimaging AT hermanterence quantitativeassessmentbymeasurementandmodelingofmobiletargetelongationinconebeamcomputedtomographicimaging AT ahmadsalahuddin quantitativeassessmentbymeasurementandmodelingofmobiletargetelongationinconebeamcomputedtomographicimaging |