Evaluation of organ doses and effective dose according to the ICRP Publication 110 reference male/female phantom and the modified ImPACT CT patient dosimetry

We modified the Imaging Performance Assessment of CT scanners (ImPACT) to evaluate the organ doses and the effective dose based on the International Commission on Radiological Protection (ICRP) Publication 110 reference male/female phantom with the Aquilion ONE ViSION Edition scanner. To select the...

Descripción completa

Detalles Bibliográficos
Autores principales: Kobayashi, Masanao, Asada, Yasuki, Matsubara, Kosuke, Matsunaga, Yuta, Kawaguchi, Ai, Katada, Kazuhiro, Toyama, Hiroshi, Koshida, Kichiro, Suzuki, Shouichi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5711082/
https://www.ncbi.nlm.nih.gov/pubmed/25207566
http://dx.doi.org/10.1120/jacmp.v15i5.4823
_version_ 1783283003884044288
author Kobayashi, Masanao
Asada, Yasuki
Matsubara, Kosuke
Matsunaga, Yuta
Kawaguchi, Ai
Katada, Kazuhiro
Toyama, Hiroshi
Koshida, Kichiro
Suzuki, Shouichi
author_facet Kobayashi, Masanao
Asada, Yasuki
Matsubara, Kosuke
Matsunaga, Yuta
Kawaguchi, Ai
Katada, Kazuhiro
Toyama, Hiroshi
Koshida, Kichiro
Suzuki, Shouichi
author_sort Kobayashi, Masanao
collection PubMed
description We modified the Imaging Performance Assessment of CT scanners (ImPACT) to evaluate the organ doses and the effective dose based on the International Commission on Radiological Protection (ICRP) Publication 110 reference male/female phantom with the Aquilion ONE ViSION Edition scanner. To select the new CT scanner, the measurement results of the [Formula: see text] and [Formula: see text] for the 160 (head) and the 320 (body) mm polymethylmethacrylate phantoms, respectively, were entered on the Excel worksheet. To compute the organ doses and effective dose of the ICRP reference male/female phantom, the conversion factors obtained by comparison between the organ doses of different types of phantom were applied. The organ doses and the effective dose were almost identical for the ICRP reference male/female and modified ImPACT. The results of this study showed that, with the dose assessment of the ImPACT, the difference in sex influences only testes and ovaries. Because the MIRD‐5 phantom represents a partially hermaphrodite adult, the phantom has the dimensions of the male reference man including testes, ovaries, and uterus but no female breasts, whereas the ICRP male/female phantom includes whole‐body male and female anatomies based on high‐resolution anatomical datasets. The conversion factors can be used to estimate the doses of a male and a female accurately, and efficient dose assessment can be performed with the modified ImPACT. PACS number: 87.53.LY, 87.57.Q‐, 87.57.‐s
format Online
Article
Text
id pubmed-5711082
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57110822018-04-02 Evaluation of organ doses and effective dose according to the ICRP Publication 110 reference male/female phantom and the modified ImPACT CT patient dosimetry Kobayashi, Masanao Asada, Yasuki Matsubara, Kosuke Matsunaga, Yuta Kawaguchi, Ai Katada, Kazuhiro Toyama, Hiroshi Koshida, Kichiro Suzuki, Shouichi J Appl Clin Med Phys Radiation Protection & Regulations We modified the Imaging Performance Assessment of CT scanners (ImPACT) to evaluate the organ doses and the effective dose based on the International Commission on Radiological Protection (ICRP) Publication 110 reference male/female phantom with the Aquilion ONE ViSION Edition scanner. To select the new CT scanner, the measurement results of the [Formula: see text] and [Formula: see text] for the 160 (head) and the 320 (body) mm polymethylmethacrylate phantoms, respectively, were entered on the Excel worksheet. To compute the organ doses and effective dose of the ICRP reference male/female phantom, the conversion factors obtained by comparison between the organ doses of different types of phantom were applied. The organ doses and the effective dose were almost identical for the ICRP reference male/female and modified ImPACT. The results of this study showed that, with the dose assessment of the ImPACT, the difference in sex influences only testes and ovaries. Because the MIRD‐5 phantom represents a partially hermaphrodite adult, the phantom has the dimensions of the male reference man including testes, ovaries, and uterus but no female breasts, whereas the ICRP male/female phantom includes whole‐body male and female anatomies based on high‐resolution anatomical datasets. The conversion factors can be used to estimate the doses of a male and a female accurately, and efficient dose assessment can be performed with the modified ImPACT. PACS number: 87.53.LY, 87.57.Q‐, 87.57.‐s John Wiley and Sons Inc. 2014-09-07 /pmc/articles/PMC5711082/ /pubmed/25207566 http://dx.doi.org/10.1120/jacmp.v15i5.4823 Text en © 2014 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Protection & Regulations
Kobayashi, Masanao
Asada, Yasuki
Matsubara, Kosuke
Matsunaga, Yuta
Kawaguchi, Ai
Katada, Kazuhiro
Toyama, Hiroshi
Koshida, Kichiro
Suzuki, Shouichi
Evaluation of organ doses and effective dose according to the ICRP Publication 110 reference male/female phantom and the modified ImPACT CT patient dosimetry
title Evaluation of organ doses and effective dose according to the ICRP Publication 110 reference male/female phantom and the modified ImPACT CT patient dosimetry
title_full Evaluation of organ doses and effective dose according to the ICRP Publication 110 reference male/female phantom and the modified ImPACT CT patient dosimetry
title_fullStr Evaluation of organ doses and effective dose according to the ICRP Publication 110 reference male/female phantom and the modified ImPACT CT patient dosimetry
title_full_unstemmed Evaluation of organ doses and effective dose according to the ICRP Publication 110 reference male/female phantom and the modified ImPACT CT patient dosimetry
title_short Evaluation of organ doses and effective dose according to the ICRP Publication 110 reference male/female phantom and the modified ImPACT CT patient dosimetry
title_sort evaluation of organ doses and effective dose according to the icrp publication 110 reference male/female phantom and the modified impact ct patient dosimetry
topic Radiation Protection & Regulations
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5711082/
https://www.ncbi.nlm.nih.gov/pubmed/25207566
http://dx.doi.org/10.1120/jacmp.v15i5.4823
work_keys_str_mv AT kobayashimasanao evaluationoforgandosesandeffectivedoseaccordingtotheicrppublication110referencemalefemalephantomandthemodifiedimpactctpatientdosimetry
AT asadayasuki evaluationoforgandosesandeffectivedoseaccordingtotheicrppublication110referencemalefemalephantomandthemodifiedimpactctpatientdosimetry
AT matsubarakosuke evaluationoforgandosesandeffectivedoseaccordingtotheicrppublication110referencemalefemalephantomandthemodifiedimpactctpatientdosimetry
AT matsunagayuta evaluationoforgandosesandeffectivedoseaccordingtotheicrppublication110referencemalefemalephantomandthemodifiedimpactctpatientdosimetry
AT kawaguchiai evaluationoforgandosesandeffectivedoseaccordingtotheicrppublication110referencemalefemalephantomandthemodifiedimpactctpatientdosimetry
AT katadakazuhiro evaluationoforgandosesandeffectivedoseaccordingtotheicrppublication110referencemalefemalephantomandthemodifiedimpactctpatientdosimetry
AT toyamahiroshi evaluationoforgandosesandeffectivedoseaccordingtotheicrppublication110referencemalefemalephantomandthemodifiedimpactctpatientdosimetry
AT koshidakichiro evaluationoforgandosesandeffectivedoseaccordingtotheicrppublication110referencemalefemalephantomandthemodifiedimpactctpatientdosimetry
AT suzukishouichi evaluationoforgandosesandeffectivedoseaccordingtotheicrppublication110referencemalefemalephantomandthemodifiedimpactctpatientdosimetry