Comparison of adverse events rates and hospital cost between customized individually made implants and standard off-the-shelf implants for total knee arthroplasty

BACKGROUND: This study compares selected hospital outcomes between patients undergoing total knee arthroplasty (TKA) using either a customized individually made (CIM) implant or a standard off-the-shelf (OTS) implant. METHODS: A retrospective review was conducted on 248 consecutive TKA patients trea...

Descripción completa

Detalles Bibliográficos
Autores principales: Culler, Steven D., Martin, Greg M., Swearingen, Alyssa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5712025/
https://www.ncbi.nlm.nih.gov/pubmed/29204493
http://dx.doi.org/10.1016/j.artd.2017.05.001
_version_ 1783283144872427520
author Culler, Steven D.
Martin, Greg M.
Swearingen, Alyssa
author_facet Culler, Steven D.
Martin, Greg M.
Swearingen, Alyssa
author_sort Culler, Steven D.
collection PubMed
description BACKGROUND: This study compares selected hospital outcomes between patients undergoing total knee arthroplasty (TKA) using either a customized individually made (CIM) implant or a standard off-the-shelf (OTS) implant. METHODS: A retrospective review was conducted on 248 consecutive TKA patients treated in a single institution, by the same surgeon. Patients received either CIM (126) or OTS (122) implants. Study data were collected from patients' medical record or the hospital's administrative billing record. Standard statistical methods tested for differences in selected outcome measures between the 2 study arms. RESULTS: Compared with the OTS implant study arm, the CIM implant study arm showed significantly lower transfusion rates (2.4% vs 11.6%; P = .005); a lower adverse event rate at both discharge (CIM 3.3% vs OTS 14.1%; P = .003) and 90 days after discharge (CIM 8.1% vs OTS 18.2%; P = .023); and a smaller percentage of patients were discharged to a rehabilitation or other acute care facility (4.8% vs 16.4%; P = .003). Total average real hospital cost for the TKA hospitalization between the 2 groups were nearly identical (CIM $16,192 vs OTS $16,240; P = .913). Finally, the risk-adjusted per patient total cost of care showed a net savings of $913.87 (P = .240) per patient for the CIM-TKA group, for bundle of care including the preoperative computed tomography scan, TKA hospitalization, and discharge disposition. CONCLUSIONS: Patients treated with a CIM implant had significantly lower transfusion rates, fewer adverse event rates, and were less likely to be discharged to a rehabilitation facility or another acute care facility. These outcomes were achieved without increasing costs.
format Online
Article
Text
id pubmed-5712025
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-57120252017-12-04 Comparison of adverse events rates and hospital cost between customized individually made implants and standard off-the-shelf implants for total knee arthroplasty Culler, Steven D. Martin, Greg M. Swearingen, Alyssa Arthroplast Today Original Research BACKGROUND: This study compares selected hospital outcomes between patients undergoing total knee arthroplasty (TKA) using either a customized individually made (CIM) implant or a standard off-the-shelf (OTS) implant. METHODS: A retrospective review was conducted on 248 consecutive TKA patients treated in a single institution, by the same surgeon. Patients received either CIM (126) or OTS (122) implants. Study data were collected from patients' medical record or the hospital's administrative billing record. Standard statistical methods tested for differences in selected outcome measures between the 2 study arms. RESULTS: Compared with the OTS implant study arm, the CIM implant study arm showed significantly lower transfusion rates (2.4% vs 11.6%; P = .005); a lower adverse event rate at both discharge (CIM 3.3% vs OTS 14.1%; P = .003) and 90 days after discharge (CIM 8.1% vs OTS 18.2%; P = .023); and a smaller percentage of patients were discharged to a rehabilitation or other acute care facility (4.8% vs 16.4%; P = .003). Total average real hospital cost for the TKA hospitalization between the 2 groups were nearly identical (CIM $16,192 vs OTS $16,240; P = .913). Finally, the risk-adjusted per patient total cost of care showed a net savings of $913.87 (P = .240) per patient for the CIM-TKA group, for bundle of care including the preoperative computed tomography scan, TKA hospitalization, and discharge disposition. CONCLUSIONS: Patients treated with a CIM implant had significantly lower transfusion rates, fewer adverse event rates, and were less likely to be discharged to a rehabilitation facility or another acute care facility. These outcomes were achieved without increasing costs. Elsevier 2017-06-09 /pmc/articles/PMC5712025/ /pubmed/29204493 http://dx.doi.org/10.1016/j.artd.2017.05.001 Text en © 2017 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research
Culler, Steven D.
Martin, Greg M.
Swearingen, Alyssa
Comparison of adverse events rates and hospital cost between customized individually made implants and standard off-the-shelf implants for total knee arthroplasty
title Comparison of adverse events rates and hospital cost between customized individually made implants and standard off-the-shelf implants for total knee arthroplasty
title_full Comparison of adverse events rates and hospital cost between customized individually made implants and standard off-the-shelf implants for total knee arthroplasty
title_fullStr Comparison of adverse events rates and hospital cost between customized individually made implants and standard off-the-shelf implants for total knee arthroplasty
title_full_unstemmed Comparison of adverse events rates and hospital cost between customized individually made implants and standard off-the-shelf implants for total knee arthroplasty
title_short Comparison of adverse events rates and hospital cost between customized individually made implants and standard off-the-shelf implants for total knee arthroplasty
title_sort comparison of adverse events rates and hospital cost between customized individually made implants and standard off-the-shelf implants for total knee arthroplasty
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5712025/
https://www.ncbi.nlm.nih.gov/pubmed/29204493
http://dx.doi.org/10.1016/j.artd.2017.05.001
work_keys_str_mv AT cullerstevend comparisonofadverseeventsratesandhospitalcostbetweencustomizedindividuallymadeimplantsandstandardofftheshelfimplantsfortotalkneearthroplasty
AT martingregm comparisonofadverseeventsratesandhospitalcostbetweencustomizedindividuallymadeimplantsandstandardofftheshelfimplantsfortotalkneearthroplasty
AT swearingenalyssa comparisonofadverseeventsratesandhospitalcostbetweencustomizedindividuallymadeimplantsandstandardofftheshelfimplantsfortotalkneearthroplasty