Comparison of adverse events rates and hospital cost between customized individually made implants and standard off-the-shelf implants for total knee arthroplasty
BACKGROUND: This study compares selected hospital outcomes between patients undergoing total knee arthroplasty (TKA) using either a customized individually made (CIM) implant or a standard off-the-shelf (OTS) implant. METHODS: A retrospective review was conducted on 248 consecutive TKA patients trea...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5712025/ https://www.ncbi.nlm.nih.gov/pubmed/29204493 http://dx.doi.org/10.1016/j.artd.2017.05.001 |
_version_ | 1783283144872427520 |
---|---|
author | Culler, Steven D. Martin, Greg M. Swearingen, Alyssa |
author_facet | Culler, Steven D. Martin, Greg M. Swearingen, Alyssa |
author_sort | Culler, Steven D. |
collection | PubMed |
description | BACKGROUND: This study compares selected hospital outcomes between patients undergoing total knee arthroplasty (TKA) using either a customized individually made (CIM) implant or a standard off-the-shelf (OTS) implant. METHODS: A retrospective review was conducted on 248 consecutive TKA patients treated in a single institution, by the same surgeon. Patients received either CIM (126) or OTS (122) implants. Study data were collected from patients' medical record or the hospital's administrative billing record. Standard statistical methods tested for differences in selected outcome measures between the 2 study arms. RESULTS: Compared with the OTS implant study arm, the CIM implant study arm showed significantly lower transfusion rates (2.4% vs 11.6%; P = .005); a lower adverse event rate at both discharge (CIM 3.3% vs OTS 14.1%; P = .003) and 90 days after discharge (CIM 8.1% vs OTS 18.2%; P = .023); and a smaller percentage of patients were discharged to a rehabilitation or other acute care facility (4.8% vs 16.4%; P = .003). Total average real hospital cost for the TKA hospitalization between the 2 groups were nearly identical (CIM $16,192 vs OTS $16,240; P = .913). Finally, the risk-adjusted per patient total cost of care showed a net savings of $913.87 (P = .240) per patient for the CIM-TKA group, for bundle of care including the preoperative computed tomography scan, TKA hospitalization, and discharge disposition. CONCLUSIONS: Patients treated with a CIM implant had significantly lower transfusion rates, fewer adverse event rates, and were less likely to be discharged to a rehabilitation facility or another acute care facility. These outcomes were achieved without increasing costs. |
format | Online Article Text |
id | pubmed-5712025 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-57120252017-12-04 Comparison of adverse events rates and hospital cost between customized individually made implants and standard off-the-shelf implants for total knee arthroplasty Culler, Steven D. Martin, Greg M. Swearingen, Alyssa Arthroplast Today Original Research BACKGROUND: This study compares selected hospital outcomes between patients undergoing total knee arthroplasty (TKA) using either a customized individually made (CIM) implant or a standard off-the-shelf (OTS) implant. METHODS: A retrospective review was conducted on 248 consecutive TKA patients treated in a single institution, by the same surgeon. Patients received either CIM (126) or OTS (122) implants. Study data were collected from patients' medical record or the hospital's administrative billing record. Standard statistical methods tested for differences in selected outcome measures between the 2 study arms. RESULTS: Compared with the OTS implant study arm, the CIM implant study arm showed significantly lower transfusion rates (2.4% vs 11.6%; P = .005); a lower adverse event rate at both discharge (CIM 3.3% vs OTS 14.1%; P = .003) and 90 days after discharge (CIM 8.1% vs OTS 18.2%; P = .023); and a smaller percentage of patients were discharged to a rehabilitation or other acute care facility (4.8% vs 16.4%; P = .003). Total average real hospital cost for the TKA hospitalization between the 2 groups were nearly identical (CIM $16,192 vs OTS $16,240; P = .913). Finally, the risk-adjusted per patient total cost of care showed a net savings of $913.87 (P = .240) per patient for the CIM-TKA group, for bundle of care including the preoperative computed tomography scan, TKA hospitalization, and discharge disposition. CONCLUSIONS: Patients treated with a CIM implant had significantly lower transfusion rates, fewer adverse event rates, and were less likely to be discharged to a rehabilitation facility or another acute care facility. These outcomes were achieved without increasing costs. Elsevier 2017-06-09 /pmc/articles/PMC5712025/ /pubmed/29204493 http://dx.doi.org/10.1016/j.artd.2017.05.001 Text en © 2017 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Research Culler, Steven D. Martin, Greg M. Swearingen, Alyssa Comparison of adverse events rates and hospital cost between customized individually made implants and standard off-the-shelf implants for total knee arthroplasty |
title | Comparison of adverse events rates and hospital cost between customized individually made implants and standard off-the-shelf implants for total knee arthroplasty |
title_full | Comparison of adverse events rates and hospital cost between customized individually made implants and standard off-the-shelf implants for total knee arthroplasty |
title_fullStr | Comparison of adverse events rates and hospital cost between customized individually made implants and standard off-the-shelf implants for total knee arthroplasty |
title_full_unstemmed | Comparison of adverse events rates and hospital cost between customized individually made implants and standard off-the-shelf implants for total knee arthroplasty |
title_short | Comparison of adverse events rates and hospital cost between customized individually made implants and standard off-the-shelf implants for total knee arthroplasty |
title_sort | comparison of adverse events rates and hospital cost between customized individually made implants and standard off-the-shelf implants for total knee arthroplasty |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5712025/ https://www.ncbi.nlm.nih.gov/pubmed/29204493 http://dx.doi.org/10.1016/j.artd.2017.05.001 |
work_keys_str_mv | AT cullerstevend comparisonofadverseeventsratesandhospitalcostbetweencustomizedindividuallymadeimplantsandstandardofftheshelfimplantsfortotalkneearthroplasty AT martingregm comparisonofadverseeventsratesandhospitalcostbetweencustomizedindividuallymadeimplantsandstandardofftheshelfimplantsfortotalkneearthroplasty AT swearingenalyssa comparisonofadverseeventsratesandhospitalcostbetweencustomizedindividuallymadeimplantsandstandardofftheshelfimplantsfortotalkneearthroplasty |