Cargando…
Design Optimisation of a Magnetic Field Based Soft Tactile Sensor
This paper investigates the design optimisation of a magnetic field based soft tactile sensor, comprised of a magnet and Hall effect module separated by an elastomer. The aim was to minimise sensitivity of the output force with respect to the input magnetic field; this was achieved by varying the ge...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5712876/ https://www.ncbi.nlm.nih.gov/pubmed/29099787 http://dx.doi.org/10.3390/s17112539 |
_version_ | 1783283306517757952 |
---|---|
author | de Boer, Gregory Raske, Nicholas Wang, Hongbo Kow, Junwai Alazmani, Ali Ghajari, Mazdak Culmer, Peter Hewson, Robert |
author_facet | de Boer, Gregory Raske, Nicholas Wang, Hongbo Kow, Junwai Alazmani, Ali Ghajari, Mazdak Culmer, Peter Hewson, Robert |
author_sort | de Boer, Gregory |
collection | PubMed |
description | This paper investigates the design optimisation of a magnetic field based soft tactile sensor, comprised of a magnet and Hall effect module separated by an elastomer. The aim was to minimise sensitivity of the output force with respect to the input magnetic field; this was achieved by varying the geometry and material properties. Finite element simulations determined the magnetic field and structural behaviour under load. Genetic programming produced phenomenological expressions describing these responses. Optimisation studies constrained by a measurable force and stable loading conditions were conducted; these produced Pareto sets of designs from which the optimal sensor characteristics were selected. The optimisation demonstrated a compromise between sensitivity and the measurable force, a fabricated version of the optimised sensor validated the improvements made using this methodology. The approach presented can be applied in general for optimising soft tactile sensor designs over a range of applications and sensing modes. |
format | Online Article Text |
id | pubmed-5712876 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-57128762017-12-07 Design Optimisation of a Magnetic Field Based Soft Tactile Sensor de Boer, Gregory Raske, Nicholas Wang, Hongbo Kow, Junwai Alazmani, Ali Ghajari, Mazdak Culmer, Peter Hewson, Robert Sensors (Basel) Article This paper investigates the design optimisation of a magnetic field based soft tactile sensor, comprised of a magnet and Hall effect module separated by an elastomer. The aim was to minimise sensitivity of the output force with respect to the input magnetic field; this was achieved by varying the geometry and material properties. Finite element simulations determined the magnetic field and structural behaviour under load. Genetic programming produced phenomenological expressions describing these responses. Optimisation studies constrained by a measurable force and stable loading conditions were conducted; these produced Pareto sets of designs from which the optimal sensor characteristics were selected. The optimisation demonstrated a compromise between sensitivity and the measurable force, a fabricated version of the optimised sensor validated the improvements made using this methodology. The approach presented can be applied in general for optimising soft tactile sensor designs over a range of applications and sensing modes. MDPI 2017-11-03 /pmc/articles/PMC5712876/ /pubmed/29099787 http://dx.doi.org/10.3390/s17112539 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article de Boer, Gregory Raske, Nicholas Wang, Hongbo Kow, Junwai Alazmani, Ali Ghajari, Mazdak Culmer, Peter Hewson, Robert Design Optimisation of a Magnetic Field Based Soft Tactile Sensor |
title | Design Optimisation of a Magnetic Field Based Soft Tactile Sensor |
title_full | Design Optimisation of a Magnetic Field Based Soft Tactile Sensor |
title_fullStr | Design Optimisation of a Magnetic Field Based Soft Tactile Sensor |
title_full_unstemmed | Design Optimisation of a Magnetic Field Based Soft Tactile Sensor |
title_short | Design Optimisation of a Magnetic Field Based Soft Tactile Sensor |
title_sort | design optimisation of a magnetic field based soft tactile sensor |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5712876/ https://www.ncbi.nlm.nih.gov/pubmed/29099787 http://dx.doi.org/10.3390/s17112539 |
work_keys_str_mv | AT deboergregory designoptimisationofamagneticfieldbasedsofttactilesensor AT raskenicholas designoptimisationofamagneticfieldbasedsofttactilesensor AT wanghongbo designoptimisationofamagneticfieldbasedsofttactilesensor AT kowjunwai designoptimisationofamagneticfieldbasedsofttactilesensor AT alazmaniali designoptimisationofamagneticfieldbasedsofttactilesensor AT ghajarimazdak designoptimisationofamagneticfieldbasedsofttactilesensor AT culmerpeter designoptimisationofamagneticfieldbasedsofttactilesensor AT hewsonrobert designoptimisationofamagneticfieldbasedsofttactilesensor |