Cargando…

A Novel Detection Method of Human Serum Albumin Based on the Poly(Thymine)-Templated Copper Nanoparticles

In this work, we developed a facile fluorescence method for quantitative detection of human serum albumin (HSA) based on the inhibition of poly(thymine) (poly T)-templated copper nanoparticles (CuNPs) in the presence of HSA. Under normal circumstances, poly T-templated CuNPs can display strong fluor...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Mingjian, Xiang, Xinying, Wu, Kefeng, He, Hailun, Chen, Hanchun, Ma, Changbei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5712895/
https://www.ncbi.nlm.nih.gov/pubmed/29160831
http://dx.doi.org/10.3390/s17112684
_version_ 1783283310978400256
author Chen, Mingjian
Xiang, Xinying
Wu, Kefeng
He, Hailun
Chen, Hanchun
Ma, Changbei
author_facet Chen, Mingjian
Xiang, Xinying
Wu, Kefeng
He, Hailun
Chen, Hanchun
Ma, Changbei
author_sort Chen, Mingjian
collection PubMed
description In this work, we developed a facile fluorescence method for quantitative detection of human serum albumin (HSA) based on the inhibition of poly(thymine) (poly T)-templated copper nanoparticles (CuNPs) in the presence of HSA. Under normal circumstances, poly T-templated CuNPs can display strong fluorescence with excitation/emission peaks at 340/610 nm. However, in the presence of HSA, it will absorb cupric ion, which will prevent the formation of CuNPs. As a result, the fluorescence intensity will become obviously lower in the presence of HSA. The analyte HSA concentration had a proportional linear relationship with the fluorescence intensity of CuNPs. The detection limit for HSA was 8.2 × 10(−8) mol·L(−1). Furthermore, it was also successfully employed to determine HSA in biological samples. Thus, this method has potential applications in point-of-care medical diagnosis and biomedical research.
format Online
Article
Text
id pubmed-5712895
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-57128952017-12-07 A Novel Detection Method of Human Serum Albumin Based on the Poly(Thymine)-Templated Copper Nanoparticles Chen, Mingjian Xiang, Xinying Wu, Kefeng He, Hailun Chen, Hanchun Ma, Changbei Sensors (Basel) Article In this work, we developed a facile fluorescence method for quantitative detection of human serum albumin (HSA) based on the inhibition of poly(thymine) (poly T)-templated copper nanoparticles (CuNPs) in the presence of HSA. Under normal circumstances, poly T-templated CuNPs can display strong fluorescence with excitation/emission peaks at 340/610 nm. However, in the presence of HSA, it will absorb cupric ion, which will prevent the formation of CuNPs. As a result, the fluorescence intensity will become obviously lower in the presence of HSA. The analyte HSA concentration had a proportional linear relationship with the fluorescence intensity of CuNPs. The detection limit for HSA was 8.2 × 10(−8) mol·L(−1). Furthermore, it was also successfully employed to determine HSA in biological samples. Thus, this method has potential applications in point-of-care medical diagnosis and biomedical research. MDPI 2017-11-21 /pmc/articles/PMC5712895/ /pubmed/29160831 http://dx.doi.org/10.3390/s17112684 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Chen, Mingjian
Xiang, Xinying
Wu, Kefeng
He, Hailun
Chen, Hanchun
Ma, Changbei
A Novel Detection Method of Human Serum Albumin Based on the Poly(Thymine)-Templated Copper Nanoparticles
title A Novel Detection Method of Human Serum Albumin Based on the Poly(Thymine)-Templated Copper Nanoparticles
title_full A Novel Detection Method of Human Serum Albumin Based on the Poly(Thymine)-Templated Copper Nanoparticles
title_fullStr A Novel Detection Method of Human Serum Albumin Based on the Poly(Thymine)-Templated Copper Nanoparticles
title_full_unstemmed A Novel Detection Method of Human Serum Albumin Based on the Poly(Thymine)-Templated Copper Nanoparticles
title_short A Novel Detection Method of Human Serum Albumin Based on the Poly(Thymine)-Templated Copper Nanoparticles
title_sort novel detection method of human serum albumin based on the poly(thymine)-templated copper nanoparticles
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5712895/
https://www.ncbi.nlm.nih.gov/pubmed/29160831
http://dx.doi.org/10.3390/s17112684
work_keys_str_mv AT chenmingjian anoveldetectionmethodofhumanserumalbuminbasedonthepolythyminetemplatedcoppernanoparticles
AT xiangxinying anoveldetectionmethodofhumanserumalbuminbasedonthepolythyminetemplatedcoppernanoparticles
AT wukefeng anoveldetectionmethodofhumanserumalbuminbasedonthepolythyminetemplatedcoppernanoparticles
AT hehailun anoveldetectionmethodofhumanserumalbuminbasedonthepolythyminetemplatedcoppernanoparticles
AT chenhanchun anoveldetectionmethodofhumanserumalbuminbasedonthepolythyminetemplatedcoppernanoparticles
AT machangbei anoveldetectionmethodofhumanserumalbuminbasedonthepolythyminetemplatedcoppernanoparticles
AT chenmingjian noveldetectionmethodofhumanserumalbuminbasedonthepolythyminetemplatedcoppernanoparticles
AT xiangxinying noveldetectionmethodofhumanserumalbuminbasedonthepolythyminetemplatedcoppernanoparticles
AT wukefeng noveldetectionmethodofhumanserumalbuminbasedonthepolythyminetemplatedcoppernanoparticles
AT hehailun noveldetectionmethodofhumanserumalbuminbasedonthepolythyminetemplatedcoppernanoparticles
AT chenhanchun noveldetectionmethodofhumanserumalbuminbasedonthepolythyminetemplatedcoppernanoparticles
AT machangbei noveldetectionmethodofhumanserumalbuminbasedonthepolythyminetemplatedcoppernanoparticles