Cargando…

In vivo geometry of the kissing stent and covered endovascular reconstruction of the aortic bifurcation configurations in aortoiliac occlusive disease

OBJECTIVES: Various configurations of kissing stent (KS) configurations exist and patency rates vary. In response the covered endovascular reconstruction of the aortic bifurcation configuration was designed to minimize mismatch and improve outcome. The aim of the current study is to compare geometri...

Descripción completa

Detalles Bibliográficos
Autores principales: Groot Jebbink, Erik, Ter Mors, Thijs G, Slump, Cornelis H, Geelkerken, Robert H, Holewijn, Suzanne, Reijnen, Michel MPJ
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5714162/
https://www.ncbi.nlm.nih.gov/pubmed/28530484
http://dx.doi.org/10.1177/1708538117708912
_version_ 1783283535869640704
author Groot Jebbink, Erik
Ter Mors, Thijs G
Slump, Cornelis H
Geelkerken, Robert H
Holewijn, Suzanne
Reijnen, Michel MPJ
author_facet Groot Jebbink, Erik
Ter Mors, Thijs G
Slump, Cornelis H
Geelkerken, Robert H
Holewijn, Suzanne
Reijnen, Michel MPJ
author_sort Groot Jebbink, Erik
collection PubMed
description OBJECTIVES: Various configurations of kissing stent (KS) configurations exist and patency rates vary. In response the covered endovascular reconstruction of the aortic bifurcation configuration was designed to minimize mismatch and improve outcome. The aim of the current study is to compare geometrical mismatch of kissing stent with the covered endovascular reconstruction of the aortic bifurcation configuration in vivo. METHODS: Post-operative computed tomographic data and patient demographics from 11 covered endovascular reconstruction of the aortic bifurcation and 11 matched kissing stent patients were included. A free hand region of interest and ellipse fitting method were applied to determine mismatch areas and volumes. Conformation of the stents to the vessel wall was expressed using the D-ratio. RESULTS: Patients were mostly treated for Rutherford category 2 and 3 (64%) with a lesion classification of TASC C and D in 82%. Radial mismatch area and volume for the covered endovascular reconstruction of the aortic bifurcation group was significantly lower compared to the kissing stent configuration (P < 0.05). The D-ratio did not significantly differ between groups. Measurements were performed with good intra-class correlation. There were no significant differences in the post-procedural aortoiliac anatomy. CONCLUSIONS: The present study shows that radial mismatch exists in vivo and that large differences in mismatch exist, in favour of the covered endovascular reconstruction of the aortic bifurcation configuration. Future research should determine if the decreased radial mismatch results in improved local flow profiles and subsequent clinical outcome.
format Online
Article
Text
id pubmed-5714162
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-57141622017-12-20 In vivo geometry of the kissing stent and covered endovascular reconstruction of the aortic bifurcation configurations in aortoiliac occlusive disease Groot Jebbink, Erik Ter Mors, Thijs G Slump, Cornelis H Geelkerken, Robert H Holewijn, Suzanne Reijnen, Michel MPJ Vascular Original Articles OBJECTIVES: Various configurations of kissing stent (KS) configurations exist and patency rates vary. In response the covered endovascular reconstruction of the aortic bifurcation configuration was designed to minimize mismatch and improve outcome. The aim of the current study is to compare geometrical mismatch of kissing stent with the covered endovascular reconstruction of the aortic bifurcation configuration in vivo. METHODS: Post-operative computed tomographic data and patient demographics from 11 covered endovascular reconstruction of the aortic bifurcation and 11 matched kissing stent patients were included. A free hand region of interest and ellipse fitting method were applied to determine mismatch areas and volumes. Conformation of the stents to the vessel wall was expressed using the D-ratio. RESULTS: Patients were mostly treated for Rutherford category 2 and 3 (64%) with a lesion classification of TASC C and D in 82%. Radial mismatch area and volume for the covered endovascular reconstruction of the aortic bifurcation group was significantly lower compared to the kissing stent configuration (P < 0.05). The D-ratio did not significantly differ between groups. Measurements were performed with good intra-class correlation. There were no significant differences in the post-procedural aortoiliac anatomy. CONCLUSIONS: The present study shows that radial mismatch exists in vivo and that large differences in mismatch exist, in favour of the covered endovascular reconstruction of the aortic bifurcation configuration. Future research should determine if the decreased radial mismatch results in improved local flow profiles and subsequent clinical outcome. SAGE Publications 2017-05-22 2017-12 /pmc/articles/PMC5714162/ /pubmed/28530484 http://dx.doi.org/10.1177/1708538117708912 Text en © The Author(s) 2017 http://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Articles
Groot Jebbink, Erik
Ter Mors, Thijs G
Slump, Cornelis H
Geelkerken, Robert H
Holewijn, Suzanne
Reijnen, Michel MPJ
In vivo geometry of the kissing stent and covered endovascular reconstruction of the aortic bifurcation configurations in aortoiliac occlusive disease
title In vivo geometry of the kissing stent and covered endovascular reconstruction of the aortic bifurcation configurations in aortoiliac occlusive disease
title_full In vivo geometry of the kissing stent and covered endovascular reconstruction of the aortic bifurcation configurations in aortoiliac occlusive disease
title_fullStr In vivo geometry of the kissing stent and covered endovascular reconstruction of the aortic bifurcation configurations in aortoiliac occlusive disease
title_full_unstemmed In vivo geometry of the kissing stent and covered endovascular reconstruction of the aortic bifurcation configurations in aortoiliac occlusive disease
title_short In vivo geometry of the kissing stent and covered endovascular reconstruction of the aortic bifurcation configurations in aortoiliac occlusive disease
title_sort in vivo geometry of the kissing stent and covered endovascular reconstruction of the aortic bifurcation configurations in aortoiliac occlusive disease
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5714162/
https://www.ncbi.nlm.nih.gov/pubmed/28530484
http://dx.doi.org/10.1177/1708538117708912
work_keys_str_mv AT grootjebbinkerik invivogeometryofthekissingstentandcoveredendovascularreconstructionoftheaorticbifurcationconfigurationsinaortoiliacocclusivedisease
AT termorsthijsg invivogeometryofthekissingstentandcoveredendovascularreconstructionoftheaorticbifurcationconfigurationsinaortoiliacocclusivedisease
AT slumpcornelish invivogeometryofthekissingstentandcoveredendovascularreconstructionoftheaorticbifurcationconfigurationsinaortoiliacocclusivedisease
AT geelkerkenroberth invivogeometryofthekissingstentandcoveredendovascularreconstructionoftheaorticbifurcationconfigurationsinaortoiliacocclusivedisease
AT holewijnsuzanne invivogeometryofthekissingstentandcoveredendovascularreconstructionoftheaorticbifurcationconfigurationsinaortoiliacocclusivedisease
AT reijnenmichelmpj invivogeometryofthekissingstentandcoveredendovascularreconstructionoftheaorticbifurcationconfigurationsinaortoiliacocclusivedisease