Cargando…
Local tumor control probability to evaluate an applicator‐guided volumetric‐modulated arc therapy solution as alternative of 3D brachytherapy for the treatment of the vaginal vault in patients affected by gynecological cancer
The purpose of this study was to evaluate the applicator‐guided volumetric‐modulated arc therapy (AGVMAT) solution as an alternative to high‐dose‐rate brachytherapy (HDR‐BRT) treatment of the vaginal vault in patients with gynecological cancer (GC). AGVMAT plans for 51 women were developed. The volu...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5714358/ https://www.ncbi.nlm.nih.gov/pubmed/23470938 http://dx.doi.org/10.1120/jacmp.v14i2.4075 |
_version_ | 1783283566351745024 |
---|---|
author | Pedicini, Piernicola Strigari, Lidia Caivano, Rocchina Fiorentino, Alba Califano, Giorgia Nappi, Antonio Improta, Giuseppina Storto, Giovanni Cozzolino, Mariella Chiumento, Costanza Fusco, Vincenzo Vavassori, Andrea Benassi, Marcello Orecchia, Roberto Salvatore, Marco |
author_facet | Pedicini, Piernicola Strigari, Lidia Caivano, Rocchina Fiorentino, Alba Califano, Giorgia Nappi, Antonio Improta, Giuseppina Storto, Giovanni Cozzolino, Mariella Chiumento, Costanza Fusco, Vincenzo Vavassori, Andrea Benassi, Marcello Orecchia, Roberto Salvatore, Marco |
author_sort | Pedicini, Piernicola |
collection | PubMed |
description | The purpose of this study was to evaluate the applicator‐guided volumetric‐modulated arc therapy (AGVMAT) solution as an alternative to high‐dose‐rate brachytherapy (HDR‐BRT) treatment of the vaginal vault in patients with gynecological cancer (GC). AGVMAT plans for 51 women were developed. The volumetric scans used for plans were obtained with an implanted CT‐compatible vaginal cylinder which provides spatial registration and immobilization of the gynecologic organs. Dosimetric and radiobiological comparisons for planning target volume (PTV) and organs at risk (OARs) were performed by means of a dose‐volume histogram (DVH), equivalent uniform dose (EUD), and local tumor control probability (LTCP). In addition, the integral dose and the overall delivery time, were evaluated. The HDR‐BRT averages of EUD and minimum LTCP were significantly higher than those of AGVMAT. Doses for the OARs were comparable for the bladder and sigmoid, while, although HDR‐BRT was able to better spare the bowel, AGVMAT provided a significant reduction of [Formula: see text] , [Formula: see text] , and [Formula: see text] ([Formula: see text]) for the rectum. AGVMAT integral doses were higher than HDR‐BRT with low values in both cases. Delivery times were about two or three times higher for HDR‐BRT with respect to the single arc technique (AGVMAT1) and dual arc technique (AGVMAT2), respectively. The applicator‐guided volumetric‐modulated arc therapy seems to have the potential of improving rectum avoidance. However, brachytherapy improves performance in terms of PTV coverage, as demonstrated by a greater EUD and better LTCP curves. PACS number: 87 |
format | Online Article Text |
id | pubmed-5714358 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-57143582018-04-02 Local tumor control probability to evaluate an applicator‐guided volumetric‐modulated arc therapy solution as alternative of 3D brachytherapy for the treatment of the vaginal vault in patients affected by gynecological cancer Pedicini, Piernicola Strigari, Lidia Caivano, Rocchina Fiorentino, Alba Califano, Giorgia Nappi, Antonio Improta, Giuseppina Storto, Giovanni Cozzolino, Mariella Chiumento, Costanza Fusco, Vincenzo Vavassori, Andrea Benassi, Marcello Orecchia, Roberto Salvatore, Marco J Appl Clin Med Phys Radiation Oncology Physics The purpose of this study was to evaluate the applicator‐guided volumetric‐modulated arc therapy (AGVMAT) solution as an alternative to high‐dose‐rate brachytherapy (HDR‐BRT) treatment of the vaginal vault in patients with gynecological cancer (GC). AGVMAT plans for 51 women were developed. The volumetric scans used for plans were obtained with an implanted CT‐compatible vaginal cylinder which provides spatial registration and immobilization of the gynecologic organs. Dosimetric and radiobiological comparisons for planning target volume (PTV) and organs at risk (OARs) were performed by means of a dose‐volume histogram (DVH), equivalent uniform dose (EUD), and local tumor control probability (LTCP). In addition, the integral dose and the overall delivery time, were evaluated. The HDR‐BRT averages of EUD and minimum LTCP were significantly higher than those of AGVMAT. Doses for the OARs were comparable for the bladder and sigmoid, while, although HDR‐BRT was able to better spare the bowel, AGVMAT provided a significant reduction of [Formula: see text] , [Formula: see text] , and [Formula: see text] ([Formula: see text]) for the rectum. AGVMAT integral doses were higher than HDR‐BRT with low values in both cases. Delivery times were about two or three times higher for HDR‐BRT with respect to the single arc technique (AGVMAT1) and dual arc technique (AGVMAT2), respectively. The applicator‐guided volumetric‐modulated arc therapy seems to have the potential of improving rectum avoidance. However, brachytherapy improves performance in terms of PTV coverage, as demonstrated by a greater EUD and better LTCP curves. PACS number: 87 John Wiley and Sons Inc. 2013-03-04 /pmc/articles/PMC5714358/ /pubmed/23470938 http://dx.doi.org/10.1120/jacmp.v14i2.4075 Text en © 2013 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Pedicini, Piernicola Strigari, Lidia Caivano, Rocchina Fiorentino, Alba Califano, Giorgia Nappi, Antonio Improta, Giuseppina Storto, Giovanni Cozzolino, Mariella Chiumento, Costanza Fusco, Vincenzo Vavassori, Andrea Benassi, Marcello Orecchia, Roberto Salvatore, Marco Local tumor control probability to evaluate an applicator‐guided volumetric‐modulated arc therapy solution as alternative of 3D brachytherapy for the treatment of the vaginal vault in patients affected by gynecological cancer |
title | Local tumor control probability to evaluate an applicator‐guided volumetric‐modulated arc therapy solution as alternative of 3D brachytherapy for the treatment of the vaginal vault in patients affected by gynecological cancer |
title_full | Local tumor control probability to evaluate an applicator‐guided volumetric‐modulated arc therapy solution as alternative of 3D brachytherapy for the treatment of the vaginal vault in patients affected by gynecological cancer |
title_fullStr | Local tumor control probability to evaluate an applicator‐guided volumetric‐modulated arc therapy solution as alternative of 3D brachytherapy for the treatment of the vaginal vault in patients affected by gynecological cancer |
title_full_unstemmed | Local tumor control probability to evaluate an applicator‐guided volumetric‐modulated arc therapy solution as alternative of 3D brachytherapy for the treatment of the vaginal vault in patients affected by gynecological cancer |
title_short | Local tumor control probability to evaluate an applicator‐guided volumetric‐modulated arc therapy solution as alternative of 3D brachytherapy for the treatment of the vaginal vault in patients affected by gynecological cancer |
title_sort | local tumor control probability to evaluate an applicator‐guided volumetric‐modulated arc therapy solution as alternative of 3d brachytherapy for the treatment of the vaginal vault in patients affected by gynecological cancer |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5714358/ https://www.ncbi.nlm.nih.gov/pubmed/23470938 http://dx.doi.org/10.1120/jacmp.v14i2.4075 |
work_keys_str_mv | AT pedicinipiernicola localtumorcontrolprobabilitytoevaluateanapplicatorguidedvolumetricmodulatedarctherapysolutionasalternativeof3dbrachytherapyforthetreatmentofthevaginalvaultinpatientsaffectedbygynecologicalcancer AT strigarilidia localtumorcontrolprobabilitytoevaluateanapplicatorguidedvolumetricmodulatedarctherapysolutionasalternativeof3dbrachytherapyforthetreatmentofthevaginalvaultinpatientsaffectedbygynecologicalcancer AT caivanorocchina localtumorcontrolprobabilitytoevaluateanapplicatorguidedvolumetricmodulatedarctherapysolutionasalternativeof3dbrachytherapyforthetreatmentofthevaginalvaultinpatientsaffectedbygynecologicalcancer AT fiorentinoalba localtumorcontrolprobabilitytoevaluateanapplicatorguidedvolumetricmodulatedarctherapysolutionasalternativeof3dbrachytherapyforthetreatmentofthevaginalvaultinpatientsaffectedbygynecologicalcancer AT califanogiorgia localtumorcontrolprobabilitytoevaluateanapplicatorguidedvolumetricmodulatedarctherapysolutionasalternativeof3dbrachytherapyforthetreatmentofthevaginalvaultinpatientsaffectedbygynecologicalcancer AT nappiantonio localtumorcontrolprobabilitytoevaluateanapplicatorguidedvolumetricmodulatedarctherapysolutionasalternativeof3dbrachytherapyforthetreatmentofthevaginalvaultinpatientsaffectedbygynecologicalcancer AT improtagiuseppina localtumorcontrolprobabilitytoevaluateanapplicatorguidedvolumetricmodulatedarctherapysolutionasalternativeof3dbrachytherapyforthetreatmentofthevaginalvaultinpatientsaffectedbygynecologicalcancer AT stortogiovanni localtumorcontrolprobabilitytoevaluateanapplicatorguidedvolumetricmodulatedarctherapysolutionasalternativeof3dbrachytherapyforthetreatmentofthevaginalvaultinpatientsaffectedbygynecologicalcancer AT cozzolinomariella localtumorcontrolprobabilitytoevaluateanapplicatorguidedvolumetricmodulatedarctherapysolutionasalternativeof3dbrachytherapyforthetreatmentofthevaginalvaultinpatientsaffectedbygynecologicalcancer AT chiumentocostanza localtumorcontrolprobabilitytoevaluateanapplicatorguidedvolumetricmodulatedarctherapysolutionasalternativeof3dbrachytherapyforthetreatmentofthevaginalvaultinpatientsaffectedbygynecologicalcancer AT fuscovincenzo localtumorcontrolprobabilitytoevaluateanapplicatorguidedvolumetricmodulatedarctherapysolutionasalternativeof3dbrachytherapyforthetreatmentofthevaginalvaultinpatientsaffectedbygynecologicalcancer AT vavassoriandrea localtumorcontrolprobabilitytoevaluateanapplicatorguidedvolumetricmodulatedarctherapysolutionasalternativeof3dbrachytherapyforthetreatmentofthevaginalvaultinpatientsaffectedbygynecologicalcancer AT benassimarcello localtumorcontrolprobabilitytoevaluateanapplicatorguidedvolumetricmodulatedarctherapysolutionasalternativeof3dbrachytherapyforthetreatmentofthevaginalvaultinpatientsaffectedbygynecologicalcancer AT orecchiaroberto localtumorcontrolprobabilitytoevaluateanapplicatorguidedvolumetricmodulatedarctherapysolutionasalternativeof3dbrachytherapyforthetreatmentofthevaginalvaultinpatientsaffectedbygynecologicalcancer AT salvatoremarco localtumorcontrolprobabilitytoevaluateanapplicatorguidedvolumetricmodulatedarctherapysolutionasalternativeof3dbrachytherapyforthetreatmentofthevaginalvaultinpatientsaffectedbygynecologicalcancer |