Cargando…
A Monte Carlo study on electron and neutron contamination caused by the presence of hip prosthesis in photon mode of a 15 MV Siemens PRIMUS linac
Several investigators have pointed out that electron and neutron contamination from high‐energy photon beams are clinically important. The aim of this study is to assess electron and neutron contamination production by various prostheses in a high‐energy photon beam of a medical linac. A 15 MV Sieme...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5714559/ https://www.ncbi.nlm.nih.gov/pubmed/24036859 http://dx.doi.org/10.1120/jacmp.v14i5.4253 |
_version_ | 1783283605664956416 |
---|---|
author | Toossi, Mohammad Taghi Bahreyni Behmadi, Marziyeh Ghorbani, Mahdi Gholamhosseinian, Hamid |
author_facet | Toossi, Mohammad Taghi Bahreyni Behmadi, Marziyeh Ghorbani, Mahdi Gholamhosseinian, Hamid |
author_sort | Toossi, Mohammad Taghi Bahreyni |
collection | PubMed |
description | Several investigators have pointed out that electron and neutron contamination from high‐energy photon beams are clinically important. The aim of this study is to assess electron and neutron contamination production by various prostheses in a high‐energy photon beam of a medical linac. A 15 MV Siemens PRIMUS linac was simulated by MCNPX Monte Carlo (MC) code and the results of percentage depth dose (PDD) and dose profile values were compared with the measured data. Electron and neutron contaminations were calculated on the beam's central axis for Co‐Cr‐Mo, stainless steel, Ti‐alloy, and Ti hip prostheses through MC simulations. Dose increase factor (DIF) was calculated as the ratio of electron (neutron) dose at a point for [Formula: see text] field size in presence of prosthesis to that at the same point in absence of prosthesis. DIF was estimated at different depths in a water phantom. Our MC‐calculated PDD and dose profile data are in good agreement with the corresponding measured values. Maximum dose increase factor for electron contamination for Co‐Cr‐Mo, stainless steel, Ti‐alloy, and Ti prostheses were equal to 1.18, 1.16, 1.16, and 1.14, respectively. The corresponding values for neutron contamination were respectively equal to: 184.55, 137.33, 40.66, and 43.17. Titanium‐based prostheses are recommended for the orthopedic practice of hip junction replacement. When treatment planning for a patient with hip prosthesis is performed for a high‐energy photon beam, attempt should be made to ensure that the prosthesis is not exposed to primary photons. PACS numbers: 87.56.bd, 87.55.kh, 87.55.Gh |
format | Online Article Text |
id | pubmed-5714559 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-57145592018-04-02 A Monte Carlo study on electron and neutron contamination caused by the presence of hip prosthesis in photon mode of a 15 MV Siemens PRIMUS linac Toossi, Mohammad Taghi Bahreyni Behmadi, Marziyeh Ghorbani, Mahdi Gholamhosseinian, Hamid J Appl Clin Med Phys Radiation Oncology Physics Several investigators have pointed out that electron and neutron contamination from high‐energy photon beams are clinically important. The aim of this study is to assess electron and neutron contamination production by various prostheses in a high‐energy photon beam of a medical linac. A 15 MV Siemens PRIMUS linac was simulated by MCNPX Monte Carlo (MC) code and the results of percentage depth dose (PDD) and dose profile values were compared with the measured data. Electron and neutron contaminations were calculated on the beam's central axis for Co‐Cr‐Mo, stainless steel, Ti‐alloy, and Ti hip prostheses through MC simulations. Dose increase factor (DIF) was calculated as the ratio of electron (neutron) dose at a point for [Formula: see text] field size in presence of prosthesis to that at the same point in absence of prosthesis. DIF was estimated at different depths in a water phantom. Our MC‐calculated PDD and dose profile data are in good agreement with the corresponding measured values. Maximum dose increase factor for electron contamination for Co‐Cr‐Mo, stainless steel, Ti‐alloy, and Ti prostheses were equal to 1.18, 1.16, 1.16, and 1.14, respectively. The corresponding values for neutron contamination were respectively equal to: 184.55, 137.33, 40.66, and 43.17. Titanium‐based prostheses are recommended for the orthopedic practice of hip junction replacement. When treatment planning for a patient with hip prosthesis is performed for a high‐energy photon beam, attempt should be made to ensure that the prosthesis is not exposed to primary photons. PACS numbers: 87.56.bd, 87.55.kh, 87.55.Gh John Wiley and Sons Inc. 2013-09-06 /pmc/articles/PMC5714559/ /pubmed/24036859 http://dx.doi.org/10.1120/jacmp.v14i5.4253 Text en © 2013 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Toossi, Mohammad Taghi Bahreyni Behmadi, Marziyeh Ghorbani, Mahdi Gholamhosseinian, Hamid A Monte Carlo study on electron and neutron contamination caused by the presence of hip prosthesis in photon mode of a 15 MV Siemens PRIMUS linac |
title | A Monte Carlo study on electron and neutron contamination caused by the presence of hip prosthesis in photon mode of a 15 MV Siemens PRIMUS linac |
title_full | A Monte Carlo study on electron and neutron contamination caused by the presence of hip prosthesis in photon mode of a 15 MV Siemens PRIMUS linac |
title_fullStr | A Monte Carlo study on electron and neutron contamination caused by the presence of hip prosthesis in photon mode of a 15 MV Siemens PRIMUS linac |
title_full_unstemmed | A Monte Carlo study on electron and neutron contamination caused by the presence of hip prosthesis in photon mode of a 15 MV Siemens PRIMUS linac |
title_short | A Monte Carlo study on electron and neutron contamination caused by the presence of hip prosthesis in photon mode of a 15 MV Siemens PRIMUS linac |
title_sort | monte carlo study on electron and neutron contamination caused by the presence of hip prosthesis in photon mode of a 15 mv siemens primus linac |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5714559/ https://www.ncbi.nlm.nih.gov/pubmed/24036859 http://dx.doi.org/10.1120/jacmp.v14i5.4253 |
work_keys_str_mv | AT toossimohammadtaghibahreyni amontecarlostudyonelectronandneutroncontaminationcausedbythepresenceofhipprosthesisinphotonmodeofa15mvsiemensprimuslinac AT behmadimarziyeh amontecarlostudyonelectronandneutroncontaminationcausedbythepresenceofhipprosthesisinphotonmodeofa15mvsiemensprimuslinac AT ghorbanimahdi amontecarlostudyonelectronandneutroncontaminationcausedbythepresenceofhipprosthesisinphotonmodeofa15mvsiemensprimuslinac AT gholamhosseinianhamid amontecarlostudyonelectronandneutroncontaminationcausedbythepresenceofhipprosthesisinphotonmodeofa15mvsiemensprimuslinac AT toossimohammadtaghibahreyni montecarlostudyonelectronandneutroncontaminationcausedbythepresenceofhipprosthesisinphotonmodeofa15mvsiemensprimuslinac AT behmadimarziyeh montecarlostudyonelectronandneutroncontaminationcausedbythepresenceofhipprosthesisinphotonmodeofa15mvsiemensprimuslinac AT ghorbanimahdi montecarlostudyonelectronandneutroncontaminationcausedbythepresenceofhipprosthesisinphotonmodeofa15mvsiemensprimuslinac AT gholamhosseinianhamid montecarlostudyonelectronandneutroncontaminationcausedbythepresenceofhipprosthesisinphotonmodeofa15mvsiemensprimuslinac |