Cargando…

Evaluation of the influence of tumor location and size on the difference of dose calculation between Ray Tracing algorithm and Fast Monte Carlo algorithm in stereotactic body radiotherapy of non‐small cell lung cancer using CyberKnife

This study evaluated the extent of improvement in dose predication accuracy achieved by the Fast Monte Carlo algorithm (MC) compared to the Ray Tracing algorithm (RAT) in stereotactic body radiotherapy (SBRT) of non‐small cell lung cancer (NSCLC), and how their differences were influenced by the tum...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Vincent W.C., Tam, Kwok‐wah, Tong, Shun‐ming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5714561/
https://www.ncbi.nlm.nih.gov/pubmed/24036860
http://dx.doi.org/10.1120/jacmp.v14i5.4280
_version_ 1783283606200778752
author Wu, Vincent W.C.
Tam, Kwok‐wah
Tong, Shun‐ming
author_facet Wu, Vincent W.C.
Tam, Kwok‐wah
Tong, Shun‐ming
author_sort Wu, Vincent W.C.
collection PubMed
description This study evaluated the extent of improvement in dose predication accuracy achieved by the Fast Monte Carlo algorithm (MC) compared to the Ray Tracing algorithm (RAT) in stereotactic body radiotherapy (SBRT) of non‐small cell lung cancer (NSCLC), and how their differences were influenced by the tumor site and size. Thirty‐three NSCLC patients treated with SBRT by CyberKnife in 2011 were recruited. They were divided into the central target group ([Formula: see text]) and peripheral target group ([Formula: see text]) according to the RTOG 0236 guidelines. Each group was further divided into the large and small target subgroups. After the computation of treatment plans using RAT, a MC plan was generated using the same patient data and treatment parameters. Apart from the target reference point dose measurements, various dose parameters for the planning target volume (PTV) and organs at risk (OARs) were assessed. In addition, the “Fractional Deviation” (FDev) was also calculated for comparison, which was defined as the ratio of the RAT and MC values. For peripheral lung cases, RAT produced significantly higher dose values in all the reference points than MC. The FDev of all reference point doses and dose parameters was greater in the small target than the large target subgroup. For central lung cases, there was no significant reference point and OAR dose differences between RAT and MC. When comparing between the small target and large target subgroups, the FDev values of all the dose parameters and reference point doses did not show significant difference. Despite the shorter computation time, RAT was inferior to MC, in which the target dose was usually overestimated. RAT would not be recommended for SBRT of peripheral lung tumors regardless of the target size. However, it could be considered for large central lung tumors because its performance was comparable to MC. PACS number: 87
format Online
Article
Text
id pubmed-5714561
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57145612018-04-02 Evaluation of the influence of tumor location and size on the difference of dose calculation between Ray Tracing algorithm and Fast Monte Carlo algorithm in stereotactic body radiotherapy of non‐small cell lung cancer using CyberKnife Wu, Vincent W.C. Tam, Kwok‐wah Tong, Shun‐ming J Appl Clin Med Phys Radiation Oncology Physics This study evaluated the extent of improvement in dose predication accuracy achieved by the Fast Monte Carlo algorithm (MC) compared to the Ray Tracing algorithm (RAT) in stereotactic body radiotherapy (SBRT) of non‐small cell lung cancer (NSCLC), and how their differences were influenced by the tumor site and size. Thirty‐three NSCLC patients treated with SBRT by CyberKnife in 2011 were recruited. They were divided into the central target group ([Formula: see text]) and peripheral target group ([Formula: see text]) according to the RTOG 0236 guidelines. Each group was further divided into the large and small target subgroups. After the computation of treatment plans using RAT, a MC plan was generated using the same patient data and treatment parameters. Apart from the target reference point dose measurements, various dose parameters for the planning target volume (PTV) and organs at risk (OARs) were assessed. In addition, the “Fractional Deviation” (FDev) was also calculated for comparison, which was defined as the ratio of the RAT and MC values. For peripheral lung cases, RAT produced significantly higher dose values in all the reference points than MC. The FDev of all reference point doses and dose parameters was greater in the small target than the large target subgroup. For central lung cases, there was no significant reference point and OAR dose differences between RAT and MC. When comparing between the small target and large target subgroups, the FDev values of all the dose parameters and reference point doses did not show significant difference. Despite the shorter computation time, RAT was inferior to MC, in which the target dose was usually overestimated. RAT would not be recommended for SBRT of peripheral lung tumors regardless of the target size. However, it could be considered for large central lung tumors because its performance was comparable to MC. PACS number: 87 John Wiley and Sons Inc. 2013-09-06 /pmc/articles/PMC5714561/ /pubmed/24036860 http://dx.doi.org/10.1120/jacmp.v14i5.4280 Text en © 2013 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Wu, Vincent W.C.
Tam, Kwok‐wah
Tong, Shun‐ming
Evaluation of the influence of tumor location and size on the difference of dose calculation between Ray Tracing algorithm and Fast Monte Carlo algorithm in stereotactic body radiotherapy of non‐small cell lung cancer using CyberKnife
title Evaluation of the influence of tumor location and size on the difference of dose calculation between Ray Tracing algorithm and Fast Monte Carlo algorithm in stereotactic body radiotherapy of non‐small cell lung cancer using CyberKnife
title_full Evaluation of the influence of tumor location and size on the difference of dose calculation between Ray Tracing algorithm and Fast Monte Carlo algorithm in stereotactic body radiotherapy of non‐small cell lung cancer using CyberKnife
title_fullStr Evaluation of the influence of tumor location and size on the difference of dose calculation between Ray Tracing algorithm and Fast Monte Carlo algorithm in stereotactic body radiotherapy of non‐small cell lung cancer using CyberKnife
title_full_unstemmed Evaluation of the influence of tumor location and size on the difference of dose calculation between Ray Tracing algorithm and Fast Monte Carlo algorithm in stereotactic body radiotherapy of non‐small cell lung cancer using CyberKnife
title_short Evaluation of the influence of tumor location and size on the difference of dose calculation between Ray Tracing algorithm and Fast Monte Carlo algorithm in stereotactic body radiotherapy of non‐small cell lung cancer using CyberKnife
title_sort evaluation of the influence of tumor location and size on the difference of dose calculation between ray tracing algorithm and fast monte carlo algorithm in stereotactic body radiotherapy of non‐small cell lung cancer using cyberknife
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5714561/
https://www.ncbi.nlm.nih.gov/pubmed/24036860
http://dx.doi.org/10.1120/jacmp.v14i5.4280
work_keys_str_mv AT wuvincentwc evaluationoftheinfluenceoftumorlocationandsizeonthedifferenceofdosecalculationbetweenraytracingalgorithmandfastmontecarloalgorithminstereotacticbodyradiotherapyofnonsmallcelllungcancerusingcyberknife
AT tamkwokwah evaluationoftheinfluenceoftumorlocationandsizeonthedifferenceofdosecalculationbetweenraytracingalgorithmandfastmontecarloalgorithminstereotacticbodyradiotherapyofnonsmallcelllungcancerusingcyberknife
AT tongshunming evaluationoftheinfluenceoftumorlocationandsizeonthedifferenceofdosecalculationbetweenraytracingalgorithmandfastmontecarloalgorithminstereotacticbodyradiotherapyofnonsmallcelllungcancerusingcyberknife