Cargando…

Negative margin technique — a novel planning strategy to improve dose conformation in SBRT using dynamic conformal arc delivery

The purpose of this study was to introduce a planning strategy for dynamic conformal arc therapy (DCAT), named negative margin technique (NMT), and evaluate its dosimetric gain in lung stereotactic body radiation therapy (SBRT). In DCAT, the field aperture is continuously conformed to the planning t...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Siyong, Kim, Taeho, Ko, Stephen J., Serago, Christopher, Smith, Ashley A., Vallow, Laura A., Peterson, Jennifer L., Lee, Rena
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5714574/
https://www.ncbi.nlm.nih.gov/pubmed/24036861
http://dx.doi.org/10.1120/jacmp.v14i5.4283
_version_ 1783283609597116416
author Kim, Siyong
Kim, Taeho
Ko, Stephen J.
Serago, Christopher
Smith, Ashley A.
Vallow, Laura A.
Peterson, Jennifer L.
Lee, Rena
author_facet Kim, Siyong
Kim, Taeho
Ko, Stephen J.
Serago, Christopher
Smith, Ashley A.
Vallow, Laura A.
Peterson, Jennifer L.
Lee, Rena
author_sort Kim, Siyong
collection PubMed
description The purpose of this study was to introduce a planning strategy for dynamic conformal arc therapy (DCAT), named negative margin technique (NMT), and evaluate its dosimetric gain in lung stereotactic body radiation therapy (SBRT). In DCAT, the field aperture is continuously conformed to the planning target volume (PTV) with an aperture margin (AM) to compensate for the penumbra effect with gantry rotation. It is a common belief the AM should be positive (or at least ‘zero'). However, the radial penumbra width becomes significantly wider because of continuously overlapped beams in arc delivery. Therefore, we hypothesize if the ‘negative margin’ is applied in the radial direction, it would improve the PTV dose conformation while reducing normal tissue dose. For verification, trial plans were made using the NMT and compared with ‘zero margin (ZM)’ plans for five lung SBRT cases representing different situations depending on the location of the PTV and organs at risk. All plans met 95% PTV coverage with the prescription dose and spared the spinal cord below the tolerance. Two conventional conformation indices (the ratio of prescription isodose volume to the PTV (CI100) and the ratio of 50% prescription isodose volume to the PTV (CI50)) and a modified conformation index were investigated. The maximum dose at 2 cm from the PTV [Formula: see text] and the percent of lung volume receiving 20 Gy [Formula: see text] were also evaluated. Another planning simulation was performed with a total of ten randomly selected lung SBRT cases to mimic actual practice. In this simulation, optimization with ZM was first performed and further optimization using the NMT was processed for cases that could not meet a goal of [Formula: see text] with the ZM optimization. In all cases, both the [Formula: see text] and [Formula: see text] values were significantly reduced (overall, [Formula: see text] and [Formula: see text] for [Formula: see text] and [Formula: see text] , respectively). The modified conformation index values also showed similar improvement (overall, [Formula: see text] increase). Reduction of [Formula: see text] was also observed in all cases [Formula: see text]. [Formula: see text] values decreased in all cases but one ([Formula: see text] , excluding the increased case). In the random group simulation, it was possible to achieve the goal with just one NMT trial for five out of six cases that did not meet the goal in the ZM optimization. Interestingly, however, one case needed as many as six iterations to get the [Formula: see text] goal. The NMT turned out to be an effective planning strategy that could bring significant improvement of dose conformation. The NMT can be easily implemented in most clinics with no prerequisite. PACS number: 87.55.D‐
format Online
Article
Text
id pubmed-5714574
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57145742018-04-02 Negative margin technique — a novel planning strategy to improve dose conformation in SBRT using dynamic conformal arc delivery Kim, Siyong Kim, Taeho Ko, Stephen J. Serago, Christopher Smith, Ashley A. Vallow, Laura A. Peterson, Jennifer L. Lee, Rena J Appl Clin Med Phys Radiation Oncology Physics The purpose of this study was to introduce a planning strategy for dynamic conformal arc therapy (DCAT), named negative margin technique (NMT), and evaluate its dosimetric gain in lung stereotactic body radiation therapy (SBRT). In DCAT, the field aperture is continuously conformed to the planning target volume (PTV) with an aperture margin (AM) to compensate for the penumbra effect with gantry rotation. It is a common belief the AM should be positive (or at least ‘zero'). However, the radial penumbra width becomes significantly wider because of continuously overlapped beams in arc delivery. Therefore, we hypothesize if the ‘negative margin’ is applied in the radial direction, it would improve the PTV dose conformation while reducing normal tissue dose. For verification, trial plans were made using the NMT and compared with ‘zero margin (ZM)’ plans for five lung SBRT cases representing different situations depending on the location of the PTV and organs at risk. All plans met 95% PTV coverage with the prescription dose and spared the spinal cord below the tolerance. Two conventional conformation indices (the ratio of prescription isodose volume to the PTV (CI100) and the ratio of 50% prescription isodose volume to the PTV (CI50)) and a modified conformation index were investigated. The maximum dose at 2 cm from the PTV [Formula: see text] and the percent of lung volume receiving 20 Gy [Formula: see text] were also evaluated. Another planning simulation was performed with a total of ten randomly selected lung SBRT cases to mimic actual practice. In this simulation, optimization with ZM was first performed and further optimization using the NMT was processed for cases that could not meet a goal of [Formula: see text] with the ZM optimization. In all cases, both the [Formula: see text] and [Formula: see text] values were significantly reduced (overall, [Formula: see text] and [Formula: see text] for [Formula: see text] and [Formula: see text] , respectively). The modified conformation index values also showed similar improvement (overall, [Formula: see text] increase). Reduction of [Formula: see text] was also observed in all cases [Formula: see text]. [Formula: see text] values decreased in all cases but one ([Formula: see text] , excluding the increased case). In the random group simulation, it was possible to achieve the goal with just one NMT trial for five out of six cases that did not meet the goal in the ZM optimization. Interestingly, however, one case needed as many as six iterations to get the [Formula: see text] goal. The NMT turned out to be an effective planning strategy that could bring significant improvement of dose conformation. The NMT can be easily implemented in most clinics with no prerequisite. PACS number: 87.55.D‐ John Wiley and Sons Inc. 2013-09-06 /pmc/articles/PMC5714574/ /pubmed/24036861 http://dx.doi.org/10.1120/jacmp.v14i5.4283 Text en © 2013 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Kim, Siyong
Kim, Taeho
Ko, Stephen J.
Serago, Christopher
Smith, Ashley A.
Vallow, Laura A.
Peterson, Jennifer L.
Lee, Rena
Negative margin technique — a novel planning strategy to improve dose conformation in SBRT using dynamic conformal arc delivery
title Negative margin technique — a novel planning strategy to improve dose conformation in SBRT using dynamic conformal arc delivery
title_full Negative margin technique — a novel planning strategy to improve dose conformation in SBRT using dynamic conformal arc delivery
title_fullStr Negative margin technique — a novel planning strategy to improve dose conformation in SBRT using dynamic conformal arc delivery
title_full_unstemmed Negative margin technique — a novel planning strategy to improve dose conformation in SBRT using dynamic conformal arc delivery
title_short Negative margin technique — a novel planning strategy to improve dose conformation in SBRT using dynamic conformal arc delivery
title_sort negative margin technique — a novel planning strategy to improve dose conformation in sbrt using dynamic conformal arc delivery
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5714574/
https://www.ncbi.nlm.nih.gov/pubmed/24036861
http://dx.doi.org/10.1120/jacmp.v14i5.4283
work_keys_str_mv AT kimsiyong negativemargintechniqueanovelplanningstrategytoimprovedoseconformationinsbrtusingdynamicconformalarcdelivery
AT kimtaeho negativemargintechniqueanovelplanningstrategytoimprovedoseconformationinsbrtusingdynamicconformalarcdelivery
AT kostephenj negativemargintechniqueanovelplanningstrategytoimprovedoseconformationinsbrtusingdynamicconformalarcdelivery
AT seragochristopher negativemargintechniqueanovelplanningstrategytoimprovedoseconformationinsbrtusingdynamicconformalarcdelivery
AT smithashleya negativemargintechniqueanovelplanningstrategytoimprovedoseconformationinsbrtusingdynamicconformalarcdelivery
AT vallowlauraa negativemargintechniqueanovelplanningstrategytoimprovedoseconformationinsbrtusingdynamicconformalarcdelivery
AT petersonjenniferl negativemargintechniqueanovelplanningstrategytoimprovedoseconformationinsbrtusingdynamicconformalarcdelivery
AT leerena negativemargintechniqueanovelplanningstrategytoimprovedoseconformationinsbrtusingdynamicconformalarcdelivery