Cargando…
Using mean dose rate to compare relative dosimetric efficiency with respect to source type and source change schedules for HDR brachytherapy°
Remote afterloading devices used for high‐dose‐rate (HDR) brachytherapy may be supplied with different sources, and these sources typically have differing initial source strengths. In addition, the proposed frequency for source changes may also vary, depending upon the source type. Dosimetric parame...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5714643/ https://www.ncbi.nlm.nih.gov/pubmed/24257270 http://dx.doi.org/10.1120/jacmp.v14i6.4239 |
_version_ | 1783283626116382720 |
---|---|
author | Davis, Stephen D. Parker, William Evans, Michael D.C. |
author_facet | Davis, Stephen D. Parker, William Evans, Michael D.C. |
author_sort | Davis, Stephen D. |
collection | PubMed |
description | Remote afterloading devices used for high‐dose‐rate (HDR) brachytherapy may be supplied with different sources, and these sources typically have differing initial source strengths. In addition, the proposed frequency for source changes may also vary, depending upon the source type. Dosimetric parameters unique to each source are often used to compare source types. However, when considering the relative dosimetric efficiency between two HDR sources, the combined effect of source type, initial source strength, and source change scheme must be considered. A method of quantifying this combined effect by calculating mean dose rate from specific dosimetric source data is discussed. This method suggests an objective manner of comparing source scheme equivalency to facilitate performing a cost ratio analysis between different HDR sources and source change schemes. PACS numbers: 87.53.Jw, 87.56.bg |
format | Online Article Text |
id | pubmed-5714643 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-57146432018-04-02 Using mean dose rate to compare relative dosimetric efficiency with respect to source type and source change schedules for HDR brachytherapy° Davis, Stephen D. Parker, William Evans, Michael D.C. J Appl Clin Med Phys Radiation Oncology Physics Remote afterloading devices used for high‐dose‐rate (HDR) brachytherapy may be supplied with different sources, and these sources typically have differing initial source strengths. In addition, the proposed frequency for source changes may also vary, depending upon the source type. Dosimetric parameters unique to each source are often used to compare source types. However, when considering the relative dosimetric efficiency between two HDR sources, the combined effect of source type, initial source strength, and source change scheme must be considered. A method of quantifying this combined effect by calculating mean dose rate from specific dosimetric source data is discussed. This method suggests an objective manner of comparing source scheme equivalency to facilitate performing a cost ratio analysis between different HDR sources and source change schemes. PACS numbers: 87.53.Jw, 87.56.bg John Wiley and Sons Inc. 2013-11-04 /pmc/articles/PMC5714643/ /pubmed/24257270 http://dx.doi.org/10.1120/jacmp.v14i6.4239 Text en © 2013 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Davis, Stephen D. Parker, William Evans, Michael D.C. Using mean dose rate to compare relative dosimetric efficiency with respect to source type and source change schedules for HDR brachytherapy° |
title | Using mean dose rate to compare relative dosimetric efficiency with respect to source type and source change schedules for HDR brachytherapy° |
title_full | Using mean dose rate to compare relative dosimetric efficiency with respect to source type and source change schedules for HDR brachytherapy° |
title_fullStr | Using mean dose rate to compare relative dosimetric efficiency with respect to source type and source change schedules for HDR brachytherapy° |
title_full_unstemmed | Using mean dose rate to compare relative dosimetric efficiency with respect to source type and source change schedules for HDR brachytherapy° |
title_short | Using mean dose rate to compare relative dosimetric efficiency with respect to source type and source change schedules for HDR brachytherapy° |
title_sort | using mean dose rate to compare relative dosimetric efficiency with respect to source type and source change schedules for hdr brachytherapy° |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5714643/ https://www.ncbi.nlm.nih.gov/pubmed/24257270 http://dx.doi.org/10.1120/jacmp.v14i6.4239 |
work_keys_str_mv | AT davisstephend usingmeandoseratetocomparerelativedosimetricefficiencywithrespecttosourcetypeandsourcechangeschedulesforhdrbrachytherapy AT parkerwilliam usingmeandoseratetocomparerelativedosimetricefficiencywithrespecttosourcetypeandsourcechangeschedulesforhdrbrachytherapy AT evansmichaeldc usingmeandoseratetocomparerelativedosimetricefficiencywithrespecttosourcetypeandsourcechangeschedulesforhdrbrachytherapy |