Cargando…

Intracavitary vaginal brachytherapy using a custom balloon applicator

A custom balloon applicator was created to deliver intracavitary high‐dose‐rate brachytherapy to a patient with a superficial vaginal cancer. The patient was unable to be treated conventionally due to an extremely narrow introitus that prevented the introduction of a conventional cylinder applicator...

Descripción completa

Detalles Bibliográficos
Autores principales: Paterson, Dean B., Pearson, Shelley M., Wilson, Andrew N.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5715253/
https://www.ncbi.nlm.nih.gov/pubmed/28661036
http://dx.doi.org/10.1002/jmrs.235
_version_ 1783283728630415360
author Paterson, Dean B.
Pearson, Shelley M.
Wilson, Andrew N.
author_facet Paterson, Dean B.
Pearson, Shelley M.
Wilson, Andrew N.
author_sort Paterson, Dean B.
collection PubMed
description A custom balloon applicator was created to deliver intracavitary high‐dose‐rate brachytherapy to a patient with a superficial vaginal cancer. The patient was unable to be treated conventionally due to an extremely narrow introitus that prevented the introduction of a conventional cylinder applicator. The custom applicator was constructed by inserting a straight titanium tandem applicator through the drainage lumen of a Foley catheter. The applicator was inserted and the catheter balloon was inflated when positioned at the vaginal apex. Three brachytherapy treatments were performed using this technique. Individual balloon eccentricities resulted in small radial tandem offsets within the balloon. This phenomenon was exploited by orientating the tandem offset in the direction of the target volume. Acceptable dosimetry was achieved for all fractions and the procedure was very well tolerated. The custom applicator was a viable solution that was safely developed in a short time frame using equipment readily available in our department.
format Online
Article
Text
id pubmed-5715253
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57152532017-12-08 Intracavitary vaginal brachytherapy using a custom balloon applicator Paterson, Dean B. Pearson, Shelley M. Wilson, Andrew N. J Med Radiat Sci Technical Evaluation A custom balloon applicator was created to deliver intracavitary high‐dose‐rate brachytherapy to a patient with a superficial vaginal cancer. The patient was unable to be treated conventionally due to an extremely narrow introitus that prevented the introduction of a conventional cylinder applicator. The custom applicator was constructed by inserting a straight titanium tandem applicator through the drainage lumen of a Foley catheter. The applicator was inserted and the catheter balloon was inflated when positioned at the vaginal apex. Three brachytherapy treatments were performed using this technique. Individual balloon eccentricities resulted in small radial tandem offsets within the balloon. This phenomenon was exploited by orientating the tandem offset in the direction of the target volume. Acceptable dosimetry was achieved for all fractions and the procedure was very well tolerated. The custom applicator was a viable solution that was safely developed in a short time frame using equipment readily available in our department. John Wiley and Sons Inc. 2017-06-29 2017-12 /pmc/articles/PMC5715253/ /pubmed/28661036 http://dx.doi.org/10.1002/jmrs.235 Text en © 2017 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Evaluation
Paterson, Dean B.
Pearson, Shelley M.
Wilson, Andrew N.
Intracavitary vaginal brachytherapy using a custom balloon applicator
title Intracavitary vaginal brachytherapy using a custom balloon applicator
title_full Intracavitary vaginal brachytherapy using a custom balloon applicator
title_fullStr Intracavitary vaginal brachytherapy using a custom balloon applicator
title_full_unstemmed Intracavitary vaginal brachytherapy using a custom balloon applicator
title_short Intracavitary vaginal brachytherapy using a custom balloon applicator
title_sort intracavitary vaginal brachytherapy using a custom balloon applicator
topic Technical Evaluation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5715253/
https://www.ncbi.nlm.nih.gov/pubmed/28661036
http://dx.doi.org/10.1002/jmrs.235
work_keys_str_mv AT patersondeanb intracavitaryvaginalbrachytherapyusingacustomballoonapplicator
AT pearsonshelleym intracavitaryvaginalbrachytherapyusingacustomballoonapplicator
AT wilsonandrewn intracavitaryvaginalbrachytherapyusingacustomballoonapplicator