Cargando…

Assessment of tetralogy of Fallot–associated congenital extracardiac vascular anomalies in pediatric patients using low-dose dual-source computed tomography

BACKGROUND: To investigate the diagnostic value of dual-source computed tomography (DSCT) in the evaluation of tetralogy of Fallot (TOF)-associated extracardiac vascular abnormalities in pediatric patients compared with transthoracic echocardiography (TTE). METHODS: One hundred and twenty-three pedi...

Descripción completa

Detalles Bibliográficos
Autores principales: Hu, Bi-yue, Shi, Ke, Deng, Yu-Ping, Diao, Kai-Yue, Xu, Hua-Yan, Li, Rui, Yang, Zhi-Gang, Guo, Ying-Kun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5715549/
https://www.ncbi.nlm.nih.gov/pubmed/29202750
http://dx.doi.org/10.1186/s12872-017-0718-8
_version_ 1783283787709284352
author Hu, Bi-yue
Shi, Ke
Deng, Yu-Ping
Diao, Kai-Yue
Xu, Hua-Yan
Li, Rui
Yang, Zhi-Gang
Guo, Ying-Kun
author_facet Hu, Bi-yue
Shi, Ke
Deng, Yu-Ping
Diao, Kai-Yue
Xu, Hua-Yan
Li, Rui
Yang, Zhi-Gang
Guo, Ying-Kun
author_sort Hu, Bi-yue
collection PubMed
description BACKGROUND: To investigate the diagnostic value of dual-source computed tomography (DSCT) in the evaluation of tetralogy of Fallot (TOF)-associated extracardiac vascular abnormalities in pediatric patients compared with transthoracic echocardiography (TTE). METHODS: One hundred and twenty-three pediatric patients diagnosed with TOF were included in this retrospective study. All patients underwent DSCT and TTE preoperatively. All associated extracardiac vascular abnormalities and their percentages were recorded. The diagnostic performances of DSCT and TTE were compared based on the surgical results. The image quality of DSCT was rated, and the effective radiation dose (ED) was calculated. RESULTS: A total of 159 associated extracardiac vascular deformities were confirmed by surgery. Patent ductus arteriosus (36, 22.64%), right-sided aortic arch (29, 18.24%), and pulmonary valve stenosis (23, 14.47%) were the most common associated extracardiac vascular abnormalities. DSCT was superior to TTE in demonstrating associated extracardiac anomalies (diagnostic accuracy: 99.13% vs. 97.39%; sensitivity: 92.45% vs. 77.07%; specificity: 99.81% vs. 99.42%). The agreement on grading the image quality of DSCT was excellent (κ = 0.80), and the mean score of the image quality was 3.39 ± 0.50. The mean ED of DSCT was 0.86 ± 0.47 mSv. CONCLUSIONS: Compared to TTE, low-dose DSCT has high diagnostic accuracy in the depiction of associated extracardiac vascular anomalies in pediatric patients with TOF, and could provide more morphological details for surgeons.
format Online
Article
Text
id pubmed-5715549
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-57155492017-12-08 Assessment of tetralogy of Fallot–associated congenital extracardiac vascular anomalies in pediatric patients using low-dose dual-source computed tomography Hu, Bi-yue Shi, Ke Deng, Yu-Ping Diao, Kai-Yue Xu, Hua-Yan Li, Rui Yang, Zhi-Gang Guo, Ying-Kun BMC Cardiovasc Disord Research Article BACKGROUND: To investigate the diagnostic value of dual-source computed tomography (DSCT) in the evaluation of tetralogy of Fallot (TOF)-associated extracardiac vascular abnormalities in pediatric patients compared with transthoracic echocardiography (TTE). METHODS: One hundred and twenty-three pediatric patients diagnosed with TOF were included in this retrospective study. All patients underwent DSCT and TTE preoperatively. All associated extracardiac vascular abnormalities and their percentages were recorded. The diagnostic performances of DSCT and TTE were compared based on the surgical results. The image quality of DSCT was rated, and the effective radiation dose (ED) was calculated. RESULTS: A total of 159 associated extracardiac vascular deformities were confirmed by surgery. Patent ductus arteriosus (36, 22.64%), right-sided aortic arch (29, 18.24%), and pulmonary valve stenosis (23, 14.47%) were the most common associated extracardiac vascular abnormalities. DSCT was superior to TTE in demonstrating associated extracardiac anomalies (diagnostic accuracy: 99.13% vs. 97.39%; sensitivity: 92.45% vs. 77.07%; specificity: 99.81% vs. 99.42%). The agreement on grading the image quality of DSCT was excellent (κ = 0.80), and the mean score of the image quality was 3.39 ± 0.50. The mean ED of DSCT was 0.86 ± 0.47 mSv. CONCLUSIONS: Compared to TTE, low-dose DSCT has high diagnostic accuracy in the depiction of associated extracardiac vascular anomalies in pediatric patients with TOF, and could provide more morphological details for surgeons. BioMed Central 2017-12-04 /pmc/articles/PMC5715549/ /pubmed/29202750 http://dx.doi.org/10.1186/s12872-017-0718-8 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Hu, Bi-yue
Shi, Ke
Deng, Yu-Ping
Diao, Kai-Yue
Xu, Hua-Yan
Li, Rui
Yang, Zhi-Gang
Guo, Ying-Kun
Assessment of tetralogy of Fallot–associated congenital extracardiac vascular anomalies in pediatric patients using low-dose dual-source computed tomography
title Assessment of tetralogy of Fallot–associated congenital extracardiac vascular anomalies in pediatric patients using low-dose dual-source computed tomography
title_full Assessment of tetralogy of Fallot–associated congenital extracardiac vascular anomalies in pediatric patients using low-dose dual-source computed tomography
title_fullStr Assessment of tetralogy of Fallot–associated congenital extracardiac vascular anomalies in pediatric patients using low-dose dual-source computed tomography
title_full_unstemmed Assessment of tetralogy of Fallot–associated congenital extracardiac vascular anomalies in pediatric patients using low-dose dual-source computed tomography
title_short Assessment of tetralogy of Fallot–associated congenital extracardiac vascular anomalies in pediatric patients using low-dose dual-source computed tomography
title_sort assessment of tetralogy of fallot–associated congenital extracardiac vascular anomalies in pediatric patients using low-dose dual-source computed tomography
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5715549/
https://www.ncbi.nlm.nih.gov/pubmed/29202750
http://dx.doi.org/10.1186/s12872-017-0718-8
work_keys_str_mv AT hubiyue assessmentoftetralogyoffallotassociatedcongenitalextracardiacvascularanomaliesinpediatricpatientsusinglowdosedualsourcecomputedtomography
AT shike assessmentoftetralogyoffallotassociatedcongenitalextracardiacvascularanomaliesinpediatricpatientsusinglowdosedualsourcecomputedtomography
AT dengyuping assessmentoftetralogyoffallotassociatedcongenitalextracardiacvascularanomaliesinpediatricpatientsusinglowdosedualsourcecomputedtomography
AT diaokaiyue assessmentoftetralogyoffallotassociatedcongenitalextracardiacvascularanomaliesinpediatricpatientsusinglowdosedualsourcecomputedtomography
AT xuhuayan assessmentoftetralogyoffallotassociatedcongenitalextracardiacvascularanomaliesinpediatricpatientsusinglowdosedualsourcecomputedtomography
AT lirui assessmentoftetralogyoffallotassociatedcongenitalextracardiacvascularanomaliesinpediatricpatientsusinglowdosedualsourcecomputedtomography
AT yangzhigang assessmentoftetralogyoffallotassociatedcongenitalextracardiacvascularanomaliesinpediatricpatientsusinglowdosedualsourcecomputedtomography
AT guoyingkun assessmentoftetralogyoffallotassociatedcongenitalextracardiacvascularanomaliesinpediatricpatientsusinglowdosedualsourcecomputedtomography