Cargando…
Assessment of tetralogy of Fallot–associated congenital extracardiac vascular anomalies in pediatric patients using low-dose dual-source computed tomography
BACKGROUND: To investigate the diagnostic value of dual-source computed tomography (DSCT) in the evaluation of tetralogy of Fallot (TOF)-associated extracardiac vascular abnormalities in pediatric patients compared with transthoracic echocardiography (TTE). METHODS: One hundred and twenty-three pedi...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5715549/ https://www.ncbi.nlm.nih.gov/pubmed/29202750 http://dx.doi.org/10.1186/s12872-017-0718-8 |
_version_ | 1783283787709284352 |
---|---|
author | Hu, Bi-yue Shi, Ke Deng, Yu-Ping Diao, Kai-Yue Xu, Hua-Yan Li, Rui Yang, Zhi-Gang Guo, Ying-Kun |
author_facet | Hu, Bi-yue Shi, Ke Deng, Yu-Ping Diao, Kai-Yue Xu, Hua-Yan Li, Rui Yang, Zhi-Gang Guo, Ying-Kun |
author_sort | Hu, Bi-yue |
collection | PubMed |
description | BACKGROUND: To investigate the diagnostic value of dual-source computed tomography (DSCT) in the evaluation of tetralogy of Fallot (TOF)-associated extracardiac vascular abnormalities in pediatric patients compared with transthoracic echocardiography (TTE). METHODS: One hundred and twenty-three pediatric patients diagnosed with TOF were included in this retrospective study. All patients underwent DSCT and TTE preoperatively. All associated extracardiac vascular abnormalities and their percentages were recorded. The diagnostic performances of DSCT and TTE were compared based on the surgical results. The image quality of DSCT was rated, and the effective radiation dose (ED) was calculated. RESULTS: A total of 159 associated extracardiac vascular deformities were confirmed by surgery. Patent ductus arteriosus (36, 22.64%), right-sided aortic arch (29, 18.24%), and pulmonary valve stenosis (23, 14.47%) were the most common associated extracardiac vascular abnormalities. DSCT was superior to TTE in demonstrating associated extracardiac anomalies (diagnostic accuracy: 99.13% vs. 97.39%; sensitivity: 92.45% vs. 77.07%; specificity: 99.81% vs. 99.42%). The agreement on grading the image quality of DSCT was excellent (κ = 0.80), and the mean score of the image quality was 3.39 ± 0.50. The mean ED of DSCT was 0.86 ± 0.47 mSv. CONCLUSIONS: Compared to TTE, low-dose DSCT has high diagnostic accuracy in the depiction of associated extracardiac vascular anomalies in pediatric patients with TOF, and could provide more morphological details for surgeons. |
format | Online Article Text |
id | pubmed-5715549 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-57155492017-12-08 Assessment of tetralogy of Fallot–associated congenital extracardiac vascular anomalies in pediatric patients using low-dose dual-source computed tomography Hu, Bi-yue Shi, Ke Deng, Yu-Ping Diao, Kai-Yue Xu, Hua-Yan Li, Rui Yang, Zhi-Gang Guo, Ying-Kun BMC Cardiovasc Disord Research Article BACKGROUND: To investigate the diagnostic value of dual-source computed tomography (DSCT) in the evaluation of tetralogy of Fallot (TOF)-associated extracardiac vascular abnormalities in pediatric patients compared with transthoracic echocardiography (TTE). METHODS: One hundred and twenty-three pediatric patients diagnosed with TOF were included in this retrospective study. All patients underwent DSCT and TTE preoperatively. All associated extracardiac vascular abnormalities and their percentages were recorded. The diagnostic performances of DSCT and TTE were compared based on the surgical results. The image quality of DSCT was rated, and the effective radiation dose (ED) was calculated. RESULTS: A total of 159 associated extracardiac vascular deformities were confirmed by surgery. Patent ductus arteriosus (36, 22.64%), right-sided aortic arch (29, 18.24%), and pulmonary valve stenosis (23, 14.47%) were the most common associated extracardiac vascular abnormalities. DSCT was superior to TTE in demonstrating associated extracardiac anomalies (diagnostic accuracy: 99.13% vs. 97.39%; sensitivity: 92.45% vs. 77.07%; specificity: 99.81% vs. 99.42%). The agreement on grading the image quality of DSCT was excellent (κ = 0.80), and the mean score of the image quality was 3.39 ± 0.50. The mean ED of DSCT was 0.86 ± 0.47 mSv. CONCLUSIONS: Compared to TTE, low-dose DSCT has high diagnostic accuracy in the depiction of associated extracardiac vascular anomalies in pediatric patients with TOF, and could provide more morphological details for surgeons. BioMed Central 2017-12-04 /pmc/articles/PMC5715549/ /pubmed/29202750 http://dx.doi.org/10.1186/s12872-017-0718-8 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Hu, Bi-yue Shi, Ke Deng, Yu-Ping Diao, Kai-Yue Xu, Hua-Yan Li, Rui Yang, Zhi-Gang Guo, Ying-Kun Assessment of tetralogy of Fallot–associated congenital extracardiac vascular anomalies in pediatric patients using low-dose dual-source computed tomography |
title | Assessment of tetralogy of Fallot–associated congenital extracardiac vascular anomalies in pediatric patients using low-dose dual-source computed tomography |
title_full | Assessment of tetralogy of Fallot–associated congenital extracardiac vascular anomalies in pediatric patients using low-dose dual-source computed tomography |
title_fullStr | Assessment of tetralogy of Fallot–associated congenital extracardiac vascular anomalies in pediatric patients using low-dose dual-source computed tomography |
title_full_unstemmed | Assessment of tetralogy of Fallot–associated congenital extracardiac vascular anomalies in pediatric patients using low-dose dual-source computed tomography |
title_short | Assessment of tetralogy of Fallot–associated congenital extracardiac vascular anomalies in pediatric patients using low-dose dual-source computed tomography |
title_sort | assessment of tetralogy of fallot–associated congenital extracardiac vascular anomalies in pediatric patients using low-dose dual-source computed tomography |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5715549/ https://www.ncbi.nlm.nih.gov/pubmed/29202750 http://dx.doi.org/10.1186/s12872-017-0718-8 |
work_keys_str_mv | AT hubiyue assessmentoftetralogyoffallotassociatedcongenitalextracardiacvascularanomaliesinpediatricpatientsusinglowdosedualsourcecomputedtomography AT shike assessmentoftetralogyoffallotassociatedcongenitalextracardiacvascularanomaliesinpediatricpatientsusinglowdosedualsourcecomputedtomography AT dengyuping assessmentoftetralogyoffallotassociatedcongenitalextracardiacvascularanomaliesinpediatricpatientsusinglowdosedualsourcecomputedtomography AT diaokaiyue assessmentoftetralogyoffallotassociatedcongenitalextracardiacvascularanomaliesinpediatricpatientsusinglowdosedualsourcecomputedtomography AT xuhuayan assessmentoftetralogyoffallotassociatedcongenitalextracardiacvascularanomaliesinpediatricpatientsusinglowdosedualsourcecomputedtomography AT lirui assessmentoftetralogyoffallotassociatedcongenitalextracardiacvascularanomaliesinpediatricpatientsusinglowdosedualsourcecomputedtomography AT yangzhigang assessmentoftetralogyoffallotassociatedcongenitalextracardiacvascularanomaliesinpediatricpatientsusinglowdosedualsourcecomputedtomography AT guoyingkun assessmentoftetralogyoffallotassociatedcongenitalextracardiacvascularanomaliesinpediatricpatientsusinglowdosedualsourcecomputedtomography |