Cargando…
Status of hypertension screening in the Korea National General Health Screening Program: a questionnaire survey on 210 screening centers in two metropolitan areas
BACKGROUND: The purpose of this survey was to evaluate the performance of hypertension screening in medical institutions conducting the national general health screening program of the Republic of Korea. METHODS: We contacted 700 medical institutions of Seoul and Incheon areas which performed the na...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5716058/ https://www.ncbi.nlm.nih.gov/pubmed/29225914 http://dx.doi.org/10.1186/s40885-017-0075-z |
_version_ | 1783283870440882176 |
---|---|
author | Lee, Seung Won Lee, Hae-Young Ihm, Sang Hyun Park, Sung Ha Kim, Tae Hyun Kim, Hyeon Chang |
author_facet | Lee, Seung Won Lee, Hae-Young Ihm, Sang Hyun Park, Sung Ha Kim, Tae Hyun Kim, Hyeon Chang |
author_sort | Lee, Seung Won |
collection | PubMed |
description | BACKGROUND: The purpose of this survey was to evaluate the performance of hypertension screening in medical institutions conducting the national general health screening program of the Republic of Korea. METHODS: We contacted 700 medical institutions of Seoul and Incheon areas which performed the national general health screening program in 2016, and 210 of them completed telephone survey. The questions asked in the survey include equipment, environment, personnel and quality control procedures for blood pressure (BP) measurement, and interpretation of the measurements. RESULTS: A majority of the responding screening centers used oscilloscope sphygmomanometers (51.9%), had only one-sized cuff (65.2%), and measured BP in open space (54.3%). BP levels were measured mainly by nurses (62.0%) and doctors (25.0%), after a 1 to10 minutes (84.9%) of resting period. A 75.2% of screening centers regularly calibrated sphygmomanometers, 81.4% had a manual for BP measurement, and 59.0% had a training program. A 80.0% of respondents answered that they used averages of multiple BP measurements to determine an individual’s BP level, and 82.9% answered that criteria for hypertension was systolic BP ≥140 mmHg and/or diastolic BP ≥ 90 mmHg. If a screening finds an individual with hypertension, 82.9% of centers recommend revisiting for a second BP measurement rather than start medication immediately. CONCLUSION: In most medical institutions performing general health screening program, certified medical personnel measure BP and interpret the results according to established protocols. However, there is room for improvement in the equipment, environment and quality control procedures for BP measurement. |
format | Online Article Text |
id | pubmed-5716058 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-57160582017-12-08 Status of hypertension screening in the Korea National General Health Screening Program: a questionnaire survey on 210 screening centers in two metropolitan areas Lee, Seung Won Lee, Hae-Young Ihm, Sang Hyun Park, Sung Ha Kim, Tae Hyun Kim, Hyeon Chang Clin Hypertens Research BACKGROUND: The purpose of this survey was to evaluate the performance of hypertension screening in medical institutions conducting the national general health screening program of the Republic of Korea. METHODS: We contacted 700 medical institutions of Seoul and Incheon areas which performed the national general health screening program in 2016, and 210 of them completed telephone survey. The questions asked in the survey include equipment, environment, personnel and quality control procedures for blood pressure (BP) measurement, and interpretation of the measurements. RESULTS: A majority of the responding screening centers used oscilloscope sphygmomanometers (51.9%), had only one-sized cuff (65.2%), and measured BP in open space (54.3%). BP levels were measured mainly by nurses (62.0%) and doctors (25.0%), after a 1 to10 minutes (84.9%) of resting period. A 75.2% of screening centers regularly calibrated sphygmomanometers, 81.4% had a manual for BP measurement, and 59.0% had a training program. A 80.0% of respondents answered that they used averages of multiple BP measurements to determine an individual’s BP level, and 82.9% answered that criteria for hypertension was systolic BP ≥140 mmHg and/or diastolic BP ≥ 90 mmHg. If a screening finds an individual with hypertension, 82.9% of centers recommend revisiting for a second BP measurement rather than start medication immediately. CONCLUSION: In most medical institutions performing general health screening program, certified medical personnel measure BP and interpret the results according to established protocols. However, there is room for improvement in the equipment, environment and quality control procedures for BP measurement. BioMed Central 2017-12-05 /pmc/articles/PMC5716058/ /pubmed/29225914 http://dx.doi.org/10.1186/s40885-017-0075-z Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Lee, Seung Won Lee, Hae-Young Ihm, Sang Hyun Park, Sung Ha Kim, Tae Hyun Kim, Hyeon Chang Status of hypertension screening in the Korea National General Health Screening Program: a questionnaire survey on 210 screening centers in two metropolitan areas |
title | Status of hypertension screening in the Korea National General Health Screening Program: a questionnaire survey on 210 screening centers in two metropolitan areas |
title_full | Status of hypertension screening in the Korea National General Health Screening Program: a questionnaire survey on 210 screening centers in two metropolitan areas |
title_fullStr | Status of hypertension screening in the Korea National General Health Screening Program: a questionnaire survey on 210 screening centers in two metropolitan areas |
title_full_unstemmed | Status of hypertension screening in the Korea National General Health Screening Program: a questionnaire survey on 210 screening centers in two metropolitan areas |
title_short | Status of hypertension screening in the Korea National General Health Screening Program: a questionnaire survey on 210 screening centers in two metropolitan areas |
title_sort | status of hypertension screening in the korea national general health screening program: a questionnaire survey on 210 screening centers in two metropolitan areas |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5716058/ https://www.ncbi.nlm.nih.gov/pubmed/29225914 http://dx.doi.org/10.1186/s40885-017-0075-z |
work_keys_str_mv | AT leeseungwon statusofhypertensionscreeninginthekoreanationalgeneralhealthscreeningprogramaquestionnairesurveyon210screeningcentersintwometropolitanareas AT leehaeyoung statusofhypertensionscreeninginthekoreanationalgeneralhealthscreeningprogramaquestionnairesurveyon210screeningcentersintwometropolitanareas AT ihmsanghyun statusofhypertensionscreeninginthekoreanationalgeneralhealthscreeningprogramaquestionnairesurveyon210screeningcentersintwometropolitanareas AT parksungha statusofhypertensionscreeninginthekoreanationalgeneralhealthscreeningprogramaquestionnairesurveyon210screeningcentersintwometropolitanareas AT kimtaehyun statusofhypertensionscreeninginthekoreanationalgeneralhealthscreeningprogramaquestionnairesurveyon210screeningcentersintwometropolitanareas AT kimhyeonchang statusofhypertensionscreeninginthekoreanationalgeneralhealthscreeningprogramaquestionnairesurveyon210screeningcentersintwometropolitanareas |