Cargando…

Ritornello: high fidelity control-free chromatin immunoprecipitation peak calling

With the advent of next generation high-throughput DNA sequencing technologies, omics experiments have become the mainstay for studying diverse biological effects on a genome wide scale. Chromatin immunoprecipitation (ChIP-seq) is the omics technique that enables genome wide localization of transcri...

Descripción completa

Detalles Bibliográficos
Autores principales: Stanton, Kelly P., Jin, Jiaqi, Lederman, Roy R., Weissman, Sherman M., Kluger, Yuval
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5716106/
https://www.ncbi.nlm.nih.gov/pubmed/28981893
http://dx.doi.org/10.1093/nar/gkx799
_version_ 1783283879815151616
author Stanton, Kelly P.
Jin, Jiaqi
Lederman, Roy R.
Weissman, Sherman M.
Kluger, Yuval
author_facet Stanton, Kelly P.
Jin, Jiaqi
Lederman, Roy R.
Weissman, Sherman M.
Kluger, Yuval
author_sort Stanton, Kelly P.
collection PubMed
description With the advent of next generation high-throughput DNA sequencing technologies, omics experiments have become the mainstay for studying diverse biological effects on a genome wide scale. Chromatin immunoprecipitation (ChIP-seq) is the omics technique that enables genome wide localization of transcription factor (TF) binding or epigenetic modification events. Since the inception of ChIP-seq in 2007, many methods have been developed to infer ChIP-target binding loci from the resultant reads after mapping them to a reference genome. However, interpreting these data has proven challenging, and as such these algorithms have several shortcomings, including susceptibility to false positives due to artifactual peaks, poor localization of binding sites and the requirement for a total DNA input control which increases the cost of performing these experiments. We present Ritornello, a new approach for finding TF-binding sites in ChIP-seq, with roots in digital signal processing that addresses all of these problems. We show that Ritornello generally performs equally or better than the peak callers tested and recommended by the ENCODE consortium, but in contrast, Ritornello does not require a matched total DNA input control to avoid false positives, effectively decreasing the sequencing cost to perform ChIP-seq. Ritornello is freely available at https://github.com/KlugerLab/Ritornello.
format Online
Article
Text
id pubmed-5716106
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-57161062017-12-08 Ritornello: high fidelity control-free chromatin immunoprecipitation peak calling Stanton, Kelly P. Jin, Jiaqi Lederman, Roy R. Weissman, Sherman M. Kluger, Yuval Nucleic Acids Res Methods Online With the advent of next generation high-throughput DNA sequencing technologies, omics experiments have become the mainstay for studying diverse biological effects on a genome wide scale. Chromatin immunoprecipitation (ChIP-seq) is the omics technique that enables genome wide localization of transcription factor (TF) binding or epigenetic modification events. Since the inception of ChIP-seq in 2007, many methods have been developed to infer ChIP-target binding loci from the resultant reads after mapping them to a reference genome. However, interpreting these data has proven challenging, and as such these algorithms have several shortcomings, including susceptibility to false positives due to artifactual peaks, poor localization of binding sites and the requirement for a total DNA input control which increases the cost of performing these experiments. We present Ritornello, a new approach for finding TF-binding sites in ChIP-seq, with roots in digital signal processing that addresses all of these problems. We show that Ritornello generally performs equally or better than the peak callers tested and recommended by the ENCODE consortium, but in contrast, Ritornello does not require a matched total DNA input control to avoid false positives, effectively decreasing the sequencing cost to perform ChIP-seq. Ritornello is freely available at https://github.com/KlugerLab/Ritornello. Oxford University Press 2017-12-01 2017-09-13 /pmc/articles/PMC5716106/ /pubmed/28981893 http://dx.doi.org/10.1093/nar/gkx799 Text en © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Methods Online
Stanton, Kelly P.
Jin, Jiaqi
Lederman, Roy R.
Weissman, Sherman M.
Kluger, Yuval
Ritornello: high fidelity control-free chromatin immunoprecipitation peak calling
title Ritornello: high fidelity control-free chromatin immunoprecipitation peak calling
title_full Ritornello: high fidelity control-free chromatin immunoprecipitation peak calling
title_fullStr Ritornello: high fidelity control-free chromatin immunoprecipitation peak calling
title_full_unstemmed Ritornello: high fidelity control-free chromatin immunoprecipitation peak calling
title_short Ritornello: high fidelity control-free chromatin immunoprecipitation peak calling
title_sort ritornello: high fidelity control-free chromatin immunoprecipitation peak calling
topic Methods Online
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5716106/
https://www.ncbi.nlm.nih.gov/pubmed/28981893
http://dx.doi.org/10.1093/nar/gkx799
work_keys_str_mv AT stantonkellyp ritornellohighfidelitycontrolfreechromatinimmunoprecipitationpeakcalling
AT jinjiaqi ritornellohighfidelitycontrolfreechromatinimmunoprecipitationpeakcalling
AT ledermanroyr ritornellohighfidelitycontrolfreechromatinimmunoprecipitationpeakcalling
AT weissmanshermanm ritornellohighfidelitycontrolfreechromatinimmunoprecipitationpeakcalling
AT klugeryuval ritornellohighfidelitycontrolfreechromatinimmunoprecipitationpeakcalling