An experimental investigation on the effect of beam angle optimization on the reduction of beam numbers in IMRT of head and neck tumors

In static intensity‐modulated radiation therapy (IMRT), the fundamental factors that determine the quality of a plan are the number of beams and their angles. The objective of this study is to investigate the effect of beam angle optimization (BAO) on the beam number in IMRT. We used six head and ne...

Descripción completa

Detalles Bibliográficos
Autores principales: Narayanan, V. K. Sathiya, Vaitheeswaran, R., Bhangle, Janhavi R., Basu, Sumit, Maiya, Vikram, Zade, Bhooshan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5716515/
https://www.ncbi.nlm.nih.gov/pubmed/22766955
http://dx.doi.org/10.1120/jacmp.v13i4.3912
_version_ 1783283961035751424
author Narayanan, V. K. Sathiya
Vaitheeswaran, R.
Bhangle, Janhavi R.
Basu, Sumit
Maiya, Vikram
Zade, Bhooshan
author_facet Narayanan, V. K. Sathiya
Vaitheeswaran, R.
Bhangle, Janhavi R.
Basu, Sumit
Maiya, Vikram
Zade, Bhooshan
author_sort Narayanan, V. K. Sathiya
collection PubMed
description In static intensity‐modulated radiation therapy (IMRT), the fundamental factors that determine the quality of a plan are the number of beams and their angles. The objective of this study is to investigate the effect of beam angle optimization (BAO) on the beam number in IMRT. We used six head and neck cases to carry out the study. Basically the methodology uses a parameter called “Beam Intensity Profile Perturbation Score” (BIPPS) to determine the suitable beam angles in IMRT. We used two set of plans in which one set contains plans with equispaced beam configuration starting from beam numbers 3 to 18, and another set contains plans with optimal beam angles chosen using the in‐house BAO algorithm. We used quadratic dose‐based single criteria objective function as a measure of the quality of a plan. The objective function scores obtained for equispaced beam plans and optimal beam angle plans for six head and neck cases were plotted against the beam numbers in a single graphical plot for effective comparison. It is observed that the optimization of beam angles reduces the beam numbers required to produce clinically acceptable dose distribution in IMRT of head and neck tumors. Especially [Formula: see text] (represents the beam number at which the objective function reaches a value of 0.1) is considerably reduced by beam angle optimization in almost all the cases included in the study. We believe that the experimental findings of this study will be helpful in understanding the interplay between beam angle optimization and beam number selection process in IMRT which, in turn, can be used to improve the performance of BAO algorithms and beam number selection process in IMRT. PACS number: 87.55.de
format Online
Article
Text
id pubmed-5716515
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57165152018-04-02 An experimental investigation on the effect of beam angle optimization on the reduction of beam numbers in IMRT of head and neck tumors Narayanan, V. K. Sathiya Vaitheeswaran, R. Bhangle, Janhavi R. Basu, Sumit Maiya, Vikram Zade, Bhooshan J Appl Clin Med Phys Radiation Oncology Physics In static intensity‐modulated radiation therapy (IMRT), the fundamental factors that determine the quality of a plan are the number of beams and their angles. The objective of this study is to investigate the effect of beam angle optimization (BAO) on the beam number in IMRT. We used six head and neck cases to carry out the study. Basically the methodology uses a parameter called “Beam Intensity Profile Perturbation Score” (BIPPS) to determine the suitable beam angles in IMRT. We used two set of plans in which one set contains plans with equispaced beam configuration starting from beam numbers 3 to 18, and another set contains plans with optimal beam angles chosen using the in‐house BAO algorithm. We used quadratic dose‐based single criteria objective function as a measure of the quality of a plan. The objective function scores obtained for equispaced beam plans and optimal beam angle plans for six head and neck cases were plotted against the beam numbers in a single graphical plot for effective comparison. It is observed that the optimization of beam angles reduces the beam numbers required to produce clinically acceptable dose distribution in IMRT of head and neck tumors. Especially [Formula: see text] (represents the beam number at which the objective function reaches a value of 0.1) is considerably reduced by beam angle optimization in almost all the cases included in the study. We believe that the experimental findings of this study will be helpful in understanding the interplay between beam angle optimization and beam number selection process in IMRT which, in turn, can be used to improve the performance of BAO algorithms and beam number selection process in IMRT. PACS number: 87.55.de John Wiley and Sons Inc. 2012-07-05 /pmc/articles/PMC5716515/ /pubmed/22766955 http://dx.doi.org/10.1120/jacmp.v13i4.3912 Text en © 2012 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Narayanan, V. K. Sathiya
Vaitheeswaran, R.
Bhangle, Janhavi R.
Basu, Sumit
Maiya, Vikram
Zade, Bhooshan
An experimental investigation on the effect of beam angle optimization on the reduction of beam numbers in IMRT of head and neck tumors
title An experimental investigation on the effect of beam angle optimization on the reduction of beam numbers in IMRT of head and neck tumors
title_full An experimental investigation on the effect of beam angle optimization on the reduction of beam numbers in IMRT of head and neck tumors
title_fullStr An experimental investigation on the effect of beam angle optimization on the reduction of beam numbers in IMRT of head and neck tumors
title_full_unstemmed An experimental investigation on the effect of beam angle optimization on the reduction of beam numbers in IMRT of head and neck tumors
title_short An experimental investigation on the effect of beam angle optimization on the reduction of beam numbers in IMRT of head and neck tumors
title_sort experimental investigation on the effect of beam angle optimization on the reduction of beam numbers in imrt of head and neck tumors
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5716515/
https://www.ncbi.nlm.nih.gov/pubmed/22766955
http://dx.doi.org/10.1120/jacmp.v13i4.3912
work_keys_str_mv AT narayananvksathiya anexperimentalinvestigationontheeffectofbeamangleoptimizationonthereductionofbeamnumbersinimrtofheadandnecktumors
AT vaitheeswaranr anexperimentalinvestigationontheeffectofbeamangleoptimizationonthereductionofbeamnumbersinimrtofheadandnecktumors
AT bhanglejanhavir anexperimentalinvestigationontheeffectofbeamangleoptimizationonthereductionofbeamnumbersinimrtofheadandnecktumors
AT basusumit anexperimentalinvestigationontheeffectofbeamangleoptimizationonthereductionofbeamnumbersinimrtofheadandnecktumors
AT maiyavikram anexperimentalinvestigationontheeffectofbeamangleoptimizationonthereductionofbeamnumbersinimrtofheadandnecktumors
AT zadebhooshan anexperimentalinvestigationontheeffectofbeamangleoptimizationonthereductionofbeamnumbersinimrtofheadandnecktumors
AT narayananvksathiya experimentalinvestigationontheeffectofbeamangleoptimizationonthereductionofbeamnumbersinimrtofheadandnecktumors
AT vaitheeswaranr experimentalinvestigationontheeffectofbeamangleoptimizationonthereductionofbeamnumbersinimrtofheadandnecktumors
AT bhanglejanhavir experimentalinvestigationontheeffectofbeamangleoptimizationonthereductionofbeamnumbersinimrtofheadandnecktumors
AT basusumit experimentalinvestigationontheeffectofbeamangleoptimizationonthereductionofbeamnumbersinimrtofheadandnecktumors
AT maiyavikram experimentalinvestigationontheeffectofbeamangleoptimizationonthereductionofbeamnumbersinimrtofheadandnecktumors
AT zadebhooshan experimentalinvestigationontheeffectofbeamangleoptimizationonthereductionofbeamnumbersinimrtofheadandnecktumors