An evaluation of the Clarity 3D ultrasound system for prostate localization

The purpose of this study is to evaluate the accuracy and precision of the Clarity 3D ultrasound system to track prostate gland positional variations due to setup error and organ motion. Seventeen patients ([Formula: see text]) undergoing radical external beam radiation therapy for localized prostat...

Descripción completa

Detalles Bibliográficos
Autores principales: Robinson, Don, Liu, Derek, Steciw, Stephen, Field, Colin, Daly, Helene, Saibishkumar, Elantholi P., Fallone, Gino, Parliament, Matthew, Amanie, John
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5716521/
https://www.ncbi.nlm.nih.gov/pubmed/22766945
http://dx.doi.org/10.1120/jacmp.v13i4.3753
_version_ 1783283962189185024
author Robinson, Don
Liu, Derek
Steciw, Stephen
Field, Colin
Daly, Helene
Saibishkumar, Elantholi P.
Fallone, Gino
Parliament, Matthew
Amanie, John
author_facet Robinson, Don
Liu, Derek
Steciw, Stephen
Field, Colin
Daly, Helene
Saibishkumar, Elantholi P.
Fallone, Gino
Parliament, Matthew
Amanie, John
author_sort Robinson, Don
collection PubMed
description The purpose of this study is to evaluate the accuracy and precision of the Clarity 3D ultrasound system to track prostate gland positional variations due to setup error and organ motion. Seventeen patients ([Formula: see text]) undergoing radical external beam radiation therapy for localized prostate cancer were studied. Subsequent to initial reference ultrasound and planning CT scans, each patient underwent seven repeat weekly tracking CT and ultrasound (US) scans during the course of treatment. Variations in the location of the prostate between reference and tracking scans were measured. Differences reported by CT and ultrasound scans are compared. Ultrasound tracking was initially performed clinically by a group of trained general users. Retrospective prostate localization was then performed by a trained dedicated user upon the original raw data set and also a reduced data set derived from the original by an expert user from Resonant Medical. Correlation accuracy between ultrasound and CT shifts acquired and delineated by a pool of trained general users was deemed unacceptable for radiotherapy purposes. A mean discrepancy between CT and US localizations of greater than 10 mm, with a 5 mm or greater discrepancy rate of nearly 90%, was observed. Retrospective analysis by a dedicated user of both the original and Resonant Medical reduced data sets yielded mean CT‐Us discrepancies of 8.7 mm and 7.4 mm, respectively. Unfortunately, the 5 mm or greater CT‐US discord rate for these retrospective analyses failed to drop below 80%. The greatest disparity between CT and ultrasound was consistently observed in the superior–inferior direction, while greatest agreement was achieved in the lateral dimension. Despite an expert reanalysis of the original data, the Clarity ultrasound system failed to deliver an acceptable level of geometric accuracy required for modern radiotherapy purposes. PACS numbers: 8755ne, 87.56Da, 87.63dh
format Online
Article
Text
id pubmed-5716521
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57165212018-04-02 An evaluation of the Clarity 3D ultrasound system for prostate localization Robinson, Don Liu, Derek Steciw, Stephen Field, Colin Daly, Helene Saibishkumar, Elantholi P. Fallone, Gino Parliament, Matthew Amanie, John J Appl Clin Med Phys Radiation Oncology Physics The purpose of this study is to evaluate the accuracy and precision of the Clarity 3D ultrasound system to track prostate gland positional variations due to setup error and organ motion. Seventeen patients ([Formula: see text]) undergoing radical external beam radiation therapy for localized prostate cancer were studied. Subsequent to initial reference ultrasound and planning CT scans, each patient underwent seven repeat weekly tracking CT and ultrasound (US) scans during the course of treatment. Variations in the location of the prostate between reference and tracking scans were measured. Differences reported by CT and ultrasound scans are compared. Ultrasound tracking was initially performed clinically by a group of trained general users. Retrospective prostate localization was then performed by a trained dedicated user upon the original raw data set and also a reduced data set derived from the original by an expert user from Resonant Medical. Correlation accuracy between ultrasound and CT shifts acquired and delineated by a pool of trained general users was deemed unacceptable for radiotherapy purposes. A mean discrepancy between CT and US localizations of greater than 10 mm, with a 5 mm or greater discrepancy rate of nearly 90%, was observed. Retrospective analysis by a dedicated user of both the original and Resonant Medical reduced data sets yielded mean CT‐Us discrepancies of 8.7 mm and 7.4 mm, respectively. Unfortunately, the 5 mm or greater CT‐US discord rate for these retrospective analyses failed to drop below 80%. The greatest disparity between CT and ultrasound was consistently observed in the superior–inferior direction, while greatest agreement was achieved in the lateral dimension. Despite an expert reanalysis of the original data, the Clarity ultrasound system failed to deliver an acceptable level of geometric accuracy required for modern radiotherapy purposes. PACS numbers: 8755ne, 87.56Da, 87.63dh John Wiley and Sons Inc. 2012-07-05 /pmc/articles/PMC5716521/ /pubmed/22766945 http://dx.doi.org/10.1120/jacmp.v13i4.3753 Text en © 2012 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Robinson, Don
Liu, Derek
Steciw, Stephen
Field, Colin
Daly, Helene
Saibishkumar, Elantholi P.
Fallone, Gino
Parliament, Matthew
Amanie, John
An evaluation of the Clarity 3D ultrasound system for prostate localization
title An evaluation of the Clarity 3D ultrasound system for prostate localization
title_full An evaluation of the Clarity 3D ultrasound system for prostate localization
title_fullStr An evaluation of the Clarity 3D ultrasound system for prostate localization
title_full_unstemmed An evaluation of the Clarity 3D ultrasound system for prostate localization
title_short An evaluation of the Clarity 3D ultrasound system for prostate localization
title_sort evaluation of the clarity 3d ultrasound system for prostate localization
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5716521/
https://www.ncbi.nlm.nih.gov/pubmed/22766945
http://dx.doi.org/10.1120/jacmp.v13i4.3753
work_keys_str_mv AT robinsondon anevaluationoftheclarity3dultrasoundsystemforprostatelocalization
AT liuderek anevaluationoftheclarity3dultrasoundsystemforprostatelocalization
AT steciwstephen anevaluationoftheclarity3dultrasoundsystemforprostatelocalization
AT fieldcolin anevaluationoftheclarity3dultrasoundsystemforprostatelocalization
AT dalyhelene anevaluationoftheclarity3dultrasoundsystemforprostatelocalization
AT saibishkumarelantholip anevaluationoftheclarity3dultrasoundsystemforprostatelocalization
AT fallonegino anevaluationoftheclarity3dultrasoundsystemforprostatelocalization
AT parliamentmatthew anevaluationoftheclarity3dultrasoundsystemforprostatelocalization
AT amaniejohn anevaluationoftheclarity3dultrasoundsystemforprostatelocalization
AT robinsondon evaluationoftheclarity3dultrasoundsystemforprostatelocalization
AT liuderek evaluationoftheclarity3dultrasoundsystemforprostatelocalization
AT steciwstephen evaluationoftheclarity3dultrasoundsystemforprostatelocalization
AT fieldcolin evaluationoftheclarity3dultrasoundsystemforprostatelocalization
AT dalyhelene evaluationoftheclarity3dultrasoundsystemforprostatelocalization
AT saibishkumarelantholip evaluationoftheclarity3dultrasoundsystemforprostatelocalization
AT fallonegino evaluationoftheclarity3dultrasoundsystemforprostatelocalization
AT parliamentmatthew evaluationoftheclarity3dultrasoundsystemforprostatelocalization
AT amaniejohn evaluationoftheclarity3dultrasoundsystemforprostatelocalization