Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience

American Association of Physicists in Medicine (AAPM) task group (TG) 142 has recently published a report to update recommendations of the AAPM TG 40 report and add new recommendations concerning medical accelerators in the era of image‐guided radiation therapy (IGRT). The recommendations of AAPM TG...

Descripción completa

Detalles Bibliográficos
Autores principales: Chang, Zheng, Bowsher, James, Cai, Jing, Yoo, Sua, Wang, Zhiheng, Adamson, Justus, Ren, Lei, Yin, Fang‐Fang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5716523/
https://www.ncbi.nlm.nih.gov/pubmed/22766946
http://dx.doi.org/10.1120/jacmp.v13i4.3754
_version_ 1783283962424066048
author Chang, Zheng
Bowsher, James
Cai, Jing
Yoo, Sua
Wang, Zhiheng
Adamson, Justus
Ren, Lei
Yin, Fang‐Fang
author_facet Chang, Zheng
Bowsher, James
Cai, Jing
Yoo, Sua
Wang, Zhiheng
Adamson, Justus
Ren, Lei
Yin, Fang‐Fang
author_sort Chang, Zheng
collection PubMed
description American Association of Physicists in Medicine (AAPM) task group (TG) 142 has recently published a report to update recommendations of the AAPM TG 40 report and add new recommendations concerning medical accelerators in the era of image‐guided radiation therapy (IGRT). The recommendations of AAPM TG 142 on IGRT are timely. In our institute, we established a comprehensive imaging QA program on a medical accelerator based on AAPM TG 142 and implemented it successfully. In this paper, we share our one‐year experience and performance evaluation of an OBI capable linear accelerator, Novalis Tx, per TG 142 guidelines. PACS numbers: 87.57.‐s, 87.57.C‐, 87.57.uq, 87.59.‐e, 87.59.bd
format Online
Article
Text
id pubmed-5716523
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57165232018-04-02 Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience Chang, Zheng Bowsher, James Cai, Jing Yoo, Sua Wang, Zhiheng Adamson, Justus Ren, Lei Yin, Fang‐Fang J Appl Clin Med Phys Radiation Oncology Physics American Association of Physicists in Medicine (AAPM) task group (TG) 142 has recently published a report to update recommendations of the AAPM TG 40 report and add new recommendations concerning medical accelerators in the era of image‐guided radiation therapy (IGRT). The recommendations of AAPM TG 142 on IGRT are timely. In our institute, we established a comprehensive imaging QA program on a medical accelerator based on AAPM TG 142 and implemented it successfully. In this paper, we share our one‐year experience and performance evaluation of an OBI capable linear accelerator, Novalis Tx, per TG 142 guidelines. PACS numbers: 87.57.‐s, 87.57.C‐, 87.57.uq, 87.59.‐e, 87.59.bd John Wiley and Sons Inc. 2012-07-05 /pmc/articles/PMC5716523/ /pubmed/22766946 http://dx.doi.org/10.1120/jacmp.v13i4.3754 Text en © 2012 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Chang, Zheng
Bowsher, James
Cai, Jing
Yoo, Sua
Wang, Zhiheng
Adamson, Justus
Ren, Lei
Yin, Fang‐Fang
Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience
title Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience
title_full Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience
title_fullStr Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience
title_full_unstemmed Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience
title_short Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience
title_sort imaging system qa of a medical accelerator, novalis tx, for igrt per tg 142: our 1 year experience
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5716523/
https://www.ncbi.nlm.nih.gov/pubmed/22766946
http://dx.doi.org/10.1120/jacmp.v13i4.3754
work_keys_str_mv AT changzheng imagingsystemqaofamedicalacceleratornovalistxforigrtpertg142our1yearexperience
AT bowsherjames imagingsystemqaofamedicalacceleratornovalistxforigrtpertg142our1yearexperience
AT caijing imagingsystemqaofamedicalacceleratornovalistxforigrtpertg142our1yearexperience
AT yoosua imagingsystemqaofamedicalacceleratornovalistxforigrtpertg142our1yearexperience
AT wangzhiheng imagingsystemqaofamedicalacceleratornovalistxforigrtpertg142our1yearexperience
AT adamsonjustus imagingsystemqaofamedicalacceleratornovalistxforigrtpertg142our1yearexperience
AT renlei imagingsystemqaofamedicalacceleratornovalistxforigrtpertg142our1yearexperience
AT yinfangfang imagingsystemqaofamedicalacceleratornovalistxforigrtpertg142our1yearexperience