Near-Infrared Spectroscopy versus Transcranial Doppler-Based Monitoring in Carotid Endarterectomy
BACKGROUND: Proper monitoring of cerebral perfusion during carotid artery surgery is crucial for determining if a shunt is needed. We compared the safety and reliability of near-infrared spectroscopy (NIRS) with transcranial Doppler (TCD) for cerebral monitoring. METHODS: This single-center, retrosp...
Autores principales: | Cho, Jun Woo, Jang, Jae Seok |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society for Thoracic and Cardiovascular Surgery
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5716648/ https://www.ncbi.nlm.nih.gov/pubmed/29234612 http://dx.doi.org/10.5090/kjtcs.2017.50.6.448 |
Ejemplares similares
-
Cerebral monitoring during carotid endarterectomy by transcranial Doppler ultrasonography
por: Yun, Woo-Sung
Publicado: (2017) -
Near infrared spectroscopy monitoring during carotid endarterectomy in elderly patients
por: Scolaro, A, et al.
Publicado: (2011) -
Selective Carotid Shunting Based on Intraoperative Transcranial Doppler Imaging during Carotid Endarterectomy: A Retrospective Single-Center Review
por: Cho, Jun Woo, et al.
Publicado: (2016) -
High Mini-Skin Incision during Carotid Endarterectomy for Carotid Stenosis
por: Jeon, Byeng Hun, et al.
Publicado: (2022) -
Routine versus selective near-infrared spectroscopy-guided shunting during carotid eversion endarterectomy
por: Kondov, Stoyan, et al.