Cargando…

Evaluation and efficacy of long length Pronova XR Bioabsorbable Polymer stent in the treatment of long coronary lesions

AIM: The study aims an observational registry of the long and extra-long length (>33 mm) Pronova XR stents in patients with long coronary lesions (>30 mm) in a prospective real world study. METHODS AND RESULTS: Current study was conducted at Ruby Hall Clinic Pune, between July 2012 and July 20...

Descripción completa

Detalles Bibliográficos
Autor principal: Hiremath, M.S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5717285/
https://www.ncbi.nlm.nih.gov/pubmed/29174243
http://dx.doi.org/10.1016/j.ihj.2017.05.002
_version_ 1783284113014259712
author Hiremath, M.S.
author_facet Hiremath, M.S.
author_sort Hiremath, M.S.
collection PubMed
description AIM: The study aims an observational registry of the long and extra-long length (>33 mm) Pronova XR stents in patients with long coronary lesions (>30 mm) in a prospective real world study. METHODS AND RESULTS: Current study was conducted at Ruby Hall Clinic Pune, between July 2012 and July 2013 including 30 patients who underwent PTCA using long and extra-long Pronova XR stents. Among the stents used, one stent - 33 mm, 2 stents - 38 mm, 5 stents - 43 mm and 25 stents were of 48 mm in length. In particular average stent length for the study was 46.03 mm and the average stent diameter was 3.09 ± 0.41 mm. For this study coronary angioplasty was performed using femoral approach and standard practice. Lesions were predilated using undersized balloons and study stent was deployed at pressure 7–26 atm. (12.8 ± 3.2 atm.) The successful delivery of stent at the intended lesion with visual residual stenosis less than 50% was defined as Procedural success. Follow up studies were conducted for all the patients at 30 days, 3 months and 6 months intervals. The predefined QCA parameters were calculated using Sanders Data System QCA plus software (Palo Alto, CA, USA). No procedural complication was observed during the whole study. 100% successful stent placement was achieved in all patients. Six months clinical follow-up was available for all patients. No adverse events (Acute closure, angina, REPCI, MI, death, sub acute stent thrombosis) or hospitalization was reported for any of the patients except one. The Quantative Coronary Core Lab analysis post 6 months showed well-flowing stent with average late lumen loss 0.10 mm ±0.26. CONCLUSION: In patients with long coronary lesions and very long length stent implantation series, Pronova XR showed excellent in 6 months results. This is for the first time reported that use of long length Pronova XR stents has shown so low restenosis rate and absent of mortality in six month period. These results offer a new opportunity to single long length stenting.
format Online
Article
Text
id pubmed-5717285
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-57172852018-11-01 Evaluation and efficacy of long length Pronova XR Bioabsorbable Polymer stent in the treatment of long coronary lesions Hiremath, M.S. Indian Heart J Original Article AIM: The study aims an observational registry of the long and extra-long length (>33 mm) Pronova XR stents in patients with long coronary lesions (>30 mm) in a prospective real world study. METHODS AND RESULTS: Current study was conducted at Ruby Hall Clinic Pune, between July 2012 and July 2013 including 30 patients who underwent PTCA using long and extra-long Pronova XR stents. Among the stents used, one stent - 33 mm, 2 stents - 38 mm, 5 stents - 43 mm and 25 stents were of 48 mm in length. In particular average stent length for the study was 46.03 mm and the average stent diameter was 3.09 ± 0.41 mm. For this study coronary angioplasty was performed using femoral approach and standard practice. Lesions were predilated using undersized balloons and study stent was deployed at pressure 7–26 atm. (12.8 ± 3.2 atm.) The successful delivery of stent at the intended lesion with visual residual stenosis less than 50% was defined as Procedural success. Follow up studies were conducted for all the patients at 30 days, 3 months and 6 months intervals. The predefined QCA parameters were calculated using Sanders Data System QCA plus software (Palo Alto, CA, USA). No procedural complication was observed during the whole study. 100% successful stent placement was achieved in all patients. Six months clinical follow-up was available for all patients. No adverse events (Acute closure, angina, REPCI, MI, death, sub acute stent thrombosis) or hospitalization was reported for any of the patients except one. The Quantative Coronary Core Lab analysis post 6 months showed well-flowing stent with average late lumen loss 0.10 mm ±0.26. CONCLUSION: In patients with long coronary lesions and very long length stent implantation series, Pronova XR showed excellent in 6 months results. This is for the first time reported that use of long length Pronova XR stents has shown so low restenosis rate and absent of mortality in six month period. These results offer a new opportunity to single long length stenting. Elsevier 2017 2017-06-23 /pmc/articles/PMC5717285/ /pubmed/29174243 http://dx.doi.org/10.1016/j.ihj.2017.05.002 Text en © 2017 Cardiological Society of India. Published by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Hiremath, M.S.
Evaluation and efficacy of long length Pronova XR Bioabsorbable Polymer stent in the treatment of long coronary lesions
title Evaluation and efficacy of long length Pronova XR Bioabsorbable Polymer stent in the treatment of long coronary lesions
title_full Evaluation and efficacy of long length Pronova XR Bioabsorbable Polymer stent in the treatment of long coronary lesions
title_fullStr Evaluation and efficacy of long length Pronova XR Bioabsorbable Polymer stent in the treatment of long coronary lesions
title_full_unstemmed Evaluation and efficacy of long length Pronova XR Bioabsorbable Polymer stent in the treatment of long coronary lesions
title_short Evaluation and efficacy of long length Pronova XR Bioabsorbable Polymer stent in the treatment of long coronary lesions
title_sort evaluation and efficacy of long length pronova xr bioabsorbable polymer stent in the treatment of long coronary lesions
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5717285/
https://www.ncbi.nlm.nih.gov/pubmed/29174243
http://dx.doi.org/10.1016/j.ihj.2017.05.002
work_keys_str_mv AT hiremathms evaluationandefficacyoflonglengthpronovaxrbioabsorbablepolymerstentinthetreatmentoflongcoronarylesions