Cargando…

Identification by mass spectrometry and automated susceptibility testing from positive bottles: a simple, rapid, and standardized approach to reduce the turnaround time in the management of blood cultures

BACKGROUND: Speeding up identification and antimicrobial susceptibility testing (AST) is of foremost importance in the management of blood cultures. Here, we describe a simple, rapid, and standardized approach based on a very short-term incubation on solid medium from positive blood cultures followe...

Descripción completa

Detalles Bibliográficos
Autores principales: Mauri, Carola, Principe, Luigi, Bracco, Silvia, Meroni, Elisa, Corbo, Nicoletta, Pini, Beatrice, Luzzaro, Francesco
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5717835/
https://www.ncbi.nlm.nih.gov/pubmed/29207967
http://dx.doi.org/10.1186/s12879-017-2851-5
_version_ 1783284220384247808
author Mauri, Carola
Principe, Luigi
Bracco, Silvia
Meroni, Elisa
Corbo, Nicoletta
Pini, Beatrice
Luzzaro, Francesco
author_facet Mauri, Carola
Principe, Luigi
Bracco, Silvia
Meroni, Elisa
Corbo, Nicoletta
Pini, Beatrice
Luzzaro, Francesco
author_sort Mauri, Carola
collection PubMed
description BACKGROUND: Speeding up identification and antimicrobial susceptibility testing (AST) is of foremost importance in the management of blood cultures. Here, we describe a simple, rapid, and standardized approach based on a very short-term incubation on solid medium from positive blood cultures followed by MALDI-TOF mass spectrometry identification and automated AST. The aim of the study was to evaluate the impact in the laboratory practice of this new procedure with respect to that previously used (standard method) by comparing TAT and cumulative percentage of final reports to clinicians. RESULTS: Compared with the standard method, the new procedure gave correct organism identification at genus or species level in 98.4% of monomicrobial samples. AST resulted in 97.7% essential agreement and 98.1% categorical agreement, with 0.9% minor errors, 1.0% major error, and 1.5% very major errors. The mean turnaround time to identification and AST was 61.4 h by using the new method compared to 83.1 h by using standard procedure. Concerning cumulative percentages of final reports, approximately a third of results were available at 48 h from the check-in of the sample when using the new procedure, whereas no final reports were ready at the same time with the standard method. CONCLUSIONS: The new procedure allows faster and reliable results using a simple and standardized approach. Thus, it represents an important tool for a more rapid management of blood cultures when molecular methods are not available in the laboratory.
format Online
Article
Text
id pubmed-5717835
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-57178352017-12-08 Identification by mass spectrometry and automated susceptibility testing from positive bottles: a simple, rapid, and standardized approach to reduce the turnaround time in the management of blood cultures Mauri, Carola Principe, Luigi Bracco, Silvia Meroni, Elisa Corbo, Nicoletta Pini, Beatrice Luzzaro, Francesco BMC Infect Dis Research Article BACKGROUND: Speeding up identification and antimicrobial susceptibility testing (AST) is of foremost importance in the management of blood cultures. Here, we describe a simple, rapid, and standardized approach based on a very short-term incubation on solid medium from positive blood cultures followed by MALDI-TOF mass spectrometry identification and automated AST. The aim of the study was to evaluate the impact in the laboratory practice of this new procedure with respect to that previously used (standard method) by comparing TAT and cumulative percentage of final reports to clinicians. RESULTS: Compared with the standard method, the new procedure gave correct organism identification at genus or species level in 98.4% of monomicrobial samples. AST resulted in 97.7% essential agreement and 98.1% categorical agreement, with 0.9% minor errors, 1.0% major error, and 1.5% very major errors. The mean turnaround time to identification and AST was 61.4 h by using the new method compared to 83.1 h by using standard procedure. Concerning cumulative percentages of final reports, approximately a third of results were available at 48 h from the check-in of the sample when using the new procedure, whereas no final reports were ready at the same time with the standard method. CONCLUSIONS: The new procedure allows faster and reliable results using a simple and standardized approach. Thus, it represents an important tool for a more rapid management of blood cultures when molecular methods are not available in the laboratory. BioMed Central 2017-12-06 /pmc/articles/PMC5717835/ /pubmed/29207967 http://dx.doi.org/10.1186/s12879-017-2851-5 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Mauri, Carola
Principe, Luigi
Bracco, Silvia
Meroni, Elisa
Corbo, Nicoletta
Pini, Beatrice
Luzzaro, Francesco
Identification by mass spectrometry and automated susceptibility testing from positive bottles: a simple, rapid, and standardized approach to reduce the turnaround time in the management of blood cultures
title Identification by mass spectrometry and automated susceptibility testing from positive bottles: a simple, rapid, and standardized approach to reduce the turnaround time in the management of blood cultures
title_full Identification by mass spectrometry and automated susceptibility testing from positive bottles: a simple, rapid, and standardized approach to reduce the turnaround time in the management of blood cultures
title_fullStr Identification by mass spectrometry and automated susceptibility testing from positive bottles: a simple, rapid, and standardized approach to reduce the turnaround time in the management of blood cultures
title_full_unstemmed Identification by mass spectrometry and automated susceptibility testing from positive bottles: a simple, rapid, and standardized approach to reduce the turnaround time in the management of blood cultures
title_short Identification by mass spectrometry and automated susceptibility testing from positive bottles: a simple, rapid, and standardized approach to reduce the turnaround time in the management of blood cultures
title_sort identification by mass spectrometry and automated susceptibility testing from positive bottles: a simple, rapid, and standardized approach to reduce the turnaround time in the management of blood cultures
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5717835/
https://www.ncbi.nlm.nih.gov/pubmed/29207967
http://dx.doi.org/10.1186/s12879-017-2851-5
work_keys_str_mv AT mauricarola identificationbymassspectrometryandautomatedsusceptibilitytestingfrompositivebottlesasimplerapidandstandardizedapproachtoreducetheturnaroundtimeinthemanagementofbloodcultures
AT principeluigi identificationbymassspectrometryandautomatedsusceptibilitytestingfrompositivebottlesasimplerapidandstandardizedapproachtoreducetheturnaroundtimeinthemanagementofbloodcultures
AT braccosilvia identificationbymassspectrometryandautomatedsusceptibilitytestingfrompositivebottlesasimplerapidandstandardizedapproachtoreducetheturnaroundtimeinthemanagementofbloodcultures
AT meronielisa identificationbymassspectrometryandautomatedsusceptibilitytestingfrompositivebottlesasimplerapidandstandardizedapproachtoreducetheturnaroundtimeinthemanagementofbloodcultures
AT corbonicoletta identificationbymassspectrometryandautomatedsusceptibilitytestingfrompositivebottlesasimplerapidandstandardizedapproachtoreducetheturnaroundtimeinthemanagementofbloodcultures
AT pinibeatrice identificationbymassspectrometryandautomatedsusceptibilitytestingfrompositivebottlesasimplerapidandstandardizedapproachtoreducetheturnaroundtimeinthemanagementofbloodcultures
AT luzzarofrancesco identificationbymassspectrometryandautomatedsusceptibilitytestingfrompositivebottlesasimplerapidandstandardizedapproachtoreducetheturnaroundtimeinthemanagementofbloodcultures