Evaluation of the dynamic conformal arc therapy in comparison to intensity‐modulated radiation therapy in prostate, brain, head‐and‐neck and spine tumors

To evaluate dynamic conformal arc therapy (DAT) dose distribution and clinical applicability in comparison to intensity‐modulated radiotherapy (IMRT) in different types of tumors and locations, twelve patients with prostate cancer with no node involvement and three patients with single tumors in the...

Descripción completa

Detalles Bibliográficos
Autores principales: Morales‐Paliza, Manuel A., Coffey, Charles W., Ding, George X.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5718665/
https://www.ncbi.nlm.nih.gov/pubmed/21587165
http://dx.doi.org/10.1120/jacmp.v12i2.3197
_version_ 1783284359436959744
author Morales‐Paliza, Manuel A.
Coffey, Charles W.
Ding, George X.
author_facet Morales‐Paliza, Manuel A.
Coffey, Charles W.
Ding, George X.
author_sort Morales‐Paliza, Manuel A.
collection PubMed
description To evaluate dynamic conformal arc therapy (DAT) dose distribution and clinical applicability in comparison to intensity‐modulated radiotherapy (IMRT) in different types of tumors and locations, twelve patients with prostate cancer with no node involvement and three patients with single tumors in the pituitary, in the neck and in the thoracic spinal region treated with IMRT, were retrospectively planned with DAT using Eclipse (V8.1). The prostate cases were also planned with three‐dimensional conformal radiation therapy (3DCRT). Dose distributions were evaluated through comparisons of dose‐volumetric histograms and in‐house IMRT protocol constraints, as well as validated via ion chamber array measurements. DAT plans for prostate showed a statistically comparable achievement of tumor conformity and dose sparing for bladder and rectum when compared to IMRT. Dose on femoral heads were similar to those achieved using 3DCRT. DAT could be planned with similar results to those obtained in IMRT for the dose constraints of the defined structures by using a 360° arc for the brain lesion and several arcs including noncoplanar ones for the head‐and‐neck and spinal tumors. Experimental validation of the calculated dose distributions via gamma analysis of composite distributions for DAT provided that more than 95% of the pixels satisfy the criteria 3 mm–3%, which was similar to that of IMRT. The average number of monitor units was approximately five times lower than IMRT. In conclusion, DAT is capable of providing conformal dose distributions to the targets accomplishing many of the IMRT dose constraints simultaneously. Experimental dose‐validation accuracy, ease of planning and reduced treatment times make DAT both acceptable and attractive for clinical use. PACS numbers: 87.55.D‐, 87.55.dk, 87.55.Qr, 87.56.bd, 87.56.Fc, 87.53.Kn, 87.55. de, 87.55.kd
format Online
Article
Text
id pubmed-5718665
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57186652018-04-02 Evaluation of the dynamic conformal arc therapy in comparison to intensity‐modulated radiation therapy in prostate, brain, head‐and‐neck and spine tumors Morales‐Paliza, Manuel A. Coffey, Charles W. Ding, George X. J Appl Clin Med Phys Radiation Oncology Physics To evaluate dynamic conformal arc therapy (DAT) dose distribution and clinical applicability in comparison to intensity‐modulated radiotherapy (IMRT) in different types of tumors and locations, twelve patients with prostate cancer with no node involvement and three patients with single tumors in the pituitary, in the neck and in the thoracic spinal region treated with IMRT, were retrospectively planned with DAT using Eclipse (V8.1). The prostate cases were also planned with three‐dimensional conformal radiation therapy (3DCRT). Dose distributions were evaluated through comparisons of dose‐volumetric histograms and in‐house IMRT protocol constraints, as well as validated via ion chamber array measurements. DAT plans for prostate showed a statistically comparable achievement of tumor conformity and dose sparing for bladder and rectum when compared to IMRT. Dose on femoral heads were similar to those achieved using 3DCRT. DAT could be planned with similar results to those obtained in IMRT for the dose constraints of the defined structures by using a 360° arc for the brain lesion and several arcs including noncoplanar ones for the head‐and‐neck and spinal tumors. Experimental validation of the calculated dose distributions via gamma analysis of composite distributions for DAT provided that more than 95% of the pixels satisfy the criteria 3 mm–3%, which was similar to that of IMRT. The average number of monitor units was approximately five times lower than IMRT. In conclusion, DAT is capable of providing conformal dose distributions to the targets accomplishing many of the IMRT dose constraints simultaneously. Experimental dose‐validation accuracy, ease of planning and reduced treatment times make DAT both acceptable and attractive for clinical use. PACS numbers: 87.55.D‐, 87.55.dk, 87.55.Qr, 87.56.bd, 87.56.Fc, 87.53.Kn, 87.55. de, 87.55.kd John Wiley and Sons Inc. 2010-12-19 /pmc/articles/PMC5718665/ /pubmed/21587165 http://dx.doi.org/10.1120/jacmp.v12i2.3197 Text en © 2011 The Authors. https://creativecommons.org/licenses/by/3.0/This is an open access article under the terms of the Creative Commons Attribution (https://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Morales‐Paliza, Manuel A.
Coffey, Charles W.
Ding, George X.
Evaluation of the dynamic conformal arc therapy in comparison to intensity‐modulated radiation therapy in prostate, brain, head‐and‐neck and spine tumors
title Evaluation of the dynamic conformal arc therapy in comparison to intensity‐modulated radiation therapy in prostate, brain, head‐and‐neck and spine tumors
title_full Evaluation of the dynamic conformal arc therapy in comparison to intensity‐modulated radiation therapy in prostate, brain, head‐and‐neck and spine tumors
title_fullStr Evaluation of the dynamic conformal arc therapy in comparison to intensity‐modulated radiation therapy in prostate, brain, head‐and‐neck and spine tumors
title_full_unstemmed Evaluation of the dynamic conformal arc therapy in comparison to intensity‐modulated radiation therapy in prostate, brain, head‐and‐neck and spine tumors
title_short Evaluation of the dynamic conformal arc therapy in comparison to intensity‐modulated radiation therapy in prostate, brain, head‐and‐neck and spine tumors
title_sort evaluation of the dynamic conformal arc therapy in comparison to intensity‐modulated radiation therapy in prostate, brain, head‐and‐neck and spine tumors
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5718665/
https://www.ncbi.nlm.nih.gov/pubmed/21587165
http://dx.doi.org/10.1120/jacmp.v12i2.3197
work_keys_str_mv AT moralespalizamanuela evaluationofthedynamicconformalarctherapyincomparisontointensitymodulatedradiationtherapyinprostatebrainheadandneckandspinetumors
AT coffeycharlesw evaluationofthedynamicconformalarctherapyincomparisontointensitymodulatedradiationtherapyinprostatebrainheadandneckandspinetumors
AT dinggeorgex evaluationofthedynamicconformalarctherapyincomparisontointensitymodulatedradiationtherapyinprostatebrainheadandneckandspinetumors