Cargando…

RapidArc quality assurance through MapCHECK

The purpose is to devise a patient‐specific quality assurance procedure for RapidArc radiotherapy using the MapCHECK detector array. We use our existing MapCHECK system and a Solid Water phantom with an embedded ion chamber to develop a quality assurance procedure for RapidArc treatment after commis...

Descripción completa

Detalles Bibliográficos
Autores principales: Gloi, Aime M., Buchanan, Robert E., Zuge, Corrie L., Goettler, AnnDrea M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5718678/
https://www.ncbi.nlm.nih.gov/pubmed/21587169
http://dx.doi.org/10.1120/jacmp.v12i2.3251
_version_ 1783284362320543744
author Gloi, Aime M.
Buchanan, Robert E.
Zuge, Corrie L.
Goettler, AnnDrea M.
author_facet Gloi, Aime M.
Buchanan, Robert E.
Zuge, Corrie L.
Goettler, AnnDrea M.
author_sort Gloi, Aime M.
collection PubMed
description The purpose is to devise a patient‐specific quality assurance procedure for RapidArc radiotherapy using the MapCHECK detector array. We use our existing MapCHECK system and a Solid Water phantom with an embedded ion chamber to develop a quality assurance procedure for RapidArc treatment after commissioning. The ion chamber used to measure the absolute dose is surrounded by 6 cm layers of solid water on the anterior and posterior sides. Partial arcs derived from the treatment planning system were used with MapCHECK to determine the actual shape of the dose and correct for the angular dependence. The ion chamber measurements were within 1% of the absolute doses predicted by the Eclipse treatment system. When using a partial arc from 60° to 300° on the MapCHECK array (gamma index [Formula: see text]: 3%, 3 mm, 10% threshold), we obtain a 97.52% average passing rate. A combination of ion chamber phantoms, partial arcs and the MapCHECK system can be used for quality assurance of RapidArc therapies. PACS number: 3.6.96.0
format Online
Article
Text
id pubmed-5718678
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57186782018-04-02 RapidArc quality assurance through MapCHECK Gloi, Aime M. Buchanan, Robert E. Zuge, Corrie L. Goettler, AnnDrea M. J Appl Clin Med Phys Radiation Oncology Physics The purpose is to devise a patient‐specific quality assurance procedure for RapidArc radiotherapy using the MapCHECK detector array. We use our existing MapCHECK system and a Solid Water phantom with an embedded ion chamber to develop a quality assurance procedure for RapidArc treatment after commissioning. The ion chamber used to measure the absolute dose is surrounded by 6 cm layers of solid water on the anterior and posterior sides. Partial arcs derived from the treatment planning system were used with MapCHECK to determine the actual shape of the dose and correct for the angular dependence. The ion chamber measurements were within 1% of the absolute doses predicted by the Eclipse treatment system. When using a partial arc from 60° to 300° on the MapCHECK array (gamma index [Formula: see text]: 3%, 3 mm, 10% threshold), we obtain a 97.52% average passing rate. A combination of ion chamber phantoms, partial arcs and the MapCHECK system can be used for quality assurance of RapidArc therapies. PACS number: 3.6.96.0 John Wiley and Sons Inc. 2011-01-05 /pmc/articles/PMC5718678/ /pubmed/21587169 http://dx.doi.org/10.1120/jacmp.v12i2.3251 Text en © 2011 The Authors. https://creativecommons.org/licenses/by/3.0/This is an open access article under the terms of the Creative Commons Attribution (https://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Gloi, Aime M.
Buchanan, Robert E.
Zuge, Corrie L.
Goettler, AnnDrea M.
RapidArc quality assurance through MapCHECK
title RapidArc quality assurance through MapCHECK
title_full RapidArc quality assurance through MapCHECK
title_fullStr RapidArc quality assurance through MapCHECK
title_full_unstemmed RapidArc quality assurance through MapCHECK
title_short RapidArc quality assurance through MapCHECK
title_sort rapidarc quality assurance through mapcheck
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5718678/
https://www.ncbi.nlm.nih.gov/pubmed/21587169
http://dx.doi.org/10.1120/jacmp.v12i2.3251
work_keys_str_mv AT gloiaimem rapidarcqualityassurancethroughmapcheck
AT buchananroberte rapidarcqualityassurancethroughmapcheck
AT zugecorriel rapidarcqualityassurancethroughmapcheck
AT goettleranndream rapidarcqualityassurancethroughmapcheck