Cargando…
RapidArc quality assurance through MapCHECK
The purpose is to devise a patient‐specific quality assurance procedure for RapidArc radiotherapy using the MapCHECK detector array. We use our existing MapCHECK system and a Solid Water phantom with an embedded ion chamber to develop a quality assurance procedure for RapidArc treatment after commis...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5718678/ https://www.ncbi.nlm.nih.gov/pubmed/21587169 http://dx.doi.org/10.1120/jacmp.v12i2.3251 |
_version_ | 1783284362320543744 |
---|---|
author | Gloi, Aime M. Buchanan, Robert E. Zuge, Corrie L. Goettler, AnnDrea M. |
author_facet | Gloi, Aime M. Buchanan, Robert E. Zuge, Corrie L. Goettler, AnnDrea M. |
author_sort | Gloi, Aime M. |
collection | PubMed |
description | The purpose is to devise a patient‐specific quality assurance procedure for RapidArc radiotherapy using the MapCHECK detector array. We use our existing MapCHECK system and a Solid Water phantom with an embedded ion chamber to develop a quality assurance procedure for RapidArc treatment after commissioning. The ion chamber used to measure the absolute dose is surrounded by 6 cm layers of solid water on the anterior and posterior sides. Partial arcs derived from the treatment planning system were used with MapCHECK to determine the actual shape of the dose and correct for the angular dependence. The ion chamber measurements were within 1% of the absolute doses predicted by the Eclipse treatment system. When using a partial arc from 60° to 300° on the MapCHECK array (gamma index [Formula: see text]: 3%, 3 mm, 10% threshold), we obtain a 97.52% average passing rate. A combination of ion chamber phantoms, partial arcs and the MapCHECK system can be used for quality assurance of RapidArc therapies. PACS number: 3.6.96.0 |
format | Online Article Text |
id | pubmed-5718678 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-57186782018-04-02 RapidArc quality assurance through MapCHECK Gloi, Aime M. Buchanan, Robert E. Zuge, Corrie L. Goettler, AnnDrea M. J Appl Clin Med Phys Radiation Oncology Physics The purpose is to devise a patient‐specific quality assurance procedure for RapidArc radiotherapy using the MapCHECK detector array. We use our existing MapCHECK system and a Solid Water phantom with an embedded ion chamber to develop a quality assurance procedure for RapidArc treatment after commissioning. The ion chamber used to measure the absolute dose is surrounded by 6 cm layers of solid water on the anterior and posterior sides. Partial arcs derived from the treatment planning system were used with MapCHECK to determine the actual shape of the dose and correct for the angular dependence. The ion chamber measurements were within 1% of the absolute doses predicted by the Eclipse treatment system. When using a partial arc from 60° to 300° on the MapCHECK array (gamma index [Formula: see text]: 3%, 3 mm, 10% threshold), we obtain a 97.52% average passing rate. A combination of ion chamber phantoms, partial arcs and the MapCHECK system can be used for quality assurance of RapidArc therapies. PACS number: 3.6.96.0 John Wiley and Sons Inc. 2011-01-05 /pmc/articles/PMC5718678/ /pubmed/21587169 http://dx.doi.org/10.1120/jacmp.v12i2.3251 Text en © 2011 The Authors. https://creativecommons.org/licenses/by/3.0/This is an open access article under the terms of the Creative Commons Attribution (https://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Gloi, Aime M. Buchanan, Robert E. Zuge, Corrie L. Goettler, AnnDrea M. RapidArc quality assurance through MapCHECK |
title | RapidArc quality assurance through MapCHECK |
title_full | RapidArc quality assurance through MapCHECK |
title_fullStr | RapidArc quality assurance through MapCHECK |
title_full_unstemmed | RapidArc quality assurance through MapCHECK |
title_short | RapidArc quality assurance through MapCHECK |
title_sort | rapidarc quality assurance through mapcheck |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5718678/ https://www.ncbi.nlm.nih.gov/pubmed/21587169 http://dx.doi.org/10.1120/jacmp.v12i2.3251 |
work_keys_str_mv | AT gloiaimem rapidarcqualityassurancethroughmapcheck AT buchananroberte rapidarcqualityassurancethroughmapcheck AT zugecorriel rapidarcqualityassurancethroughmapcheck AT goettleranndream rapidarcqualityassurancethroughmapcheck |