Cargando…

An analysis of the regulatory program of quality audits in radiotherapy in Brazil from 1995 to 2007

The Brazilian Institute of Radiation Protection and Dosimetry (IRD/CNEN) carried out quality assurance regulatory audits in Brazilian radiotherapy facilities from 1995 to 2007. In this work, the set of data collected from 195 radiotherapy facilities that use high‐energy photon beams are analyzed. Th...

Descripción completa

Detalles Bibliográficos
Autores principales: de Paiva, Eduardo, da Rosa, Luiz A. R., Brito, Ricardo R. A., de Sá, Lidia V., Dovales, Ana C. M., Batista, Delano V. S., Giannoni, Ricardo A., Velasco, Alexandre F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5718684/
https://www.ncbi.nlm.nih.gov/pubmed/21587175
http://dx.doi.org/10.1120/jacmp.v12i2.3330
_version_ 1783284363818958848
author de Paiva, Eduardo
da Rosa, Luiz A. R.
Brito, Ricardo R. A.
de Sá, Lidia V.
Dovales, Ana C. M.
Batista, Delano V. S.
Giannoni, Ricardo A.
Velasco, Alexandre F.
author_facet de Paiva, Eduardo
da Rosa, Luiz A. R.
Brito, Ricardo R. A.
de Sá, Lidia V.
Dovales, Ana C. M.
Batista, Delano V. S.
Giannoni, Ricardo A.
Velasco, Alexandre F.
author_sort de Paiva, Eduardo
collection PubMed
description The Brazilian Institute of Radiation Protection and Dosimetry (IRD/CNEN) carried out quality assurance regulatory audits in Brazilian radiotherapy facilities from 1995 to 2007. In this work, the set of data collected from 195 radiotherapy facilities that use high‐energy photon beams are analyzed. They include results from audits in linear electron accelerators and/or Co‐60 units. The inspectors of IRD/CNEN performed the dosimetry of high‐energy radiotherapy photon beams according to the IAEA dosimetry protocols TRS 277 and TRS 398, and the values of measurements were compared to stated values. Other aspects of radiological protection were checked during on‐site audits such as calibration certification of clinical dosimeters and portable monitors, existence and use of check source, use of barometer and thermometer, individual dose registry and training of staff. It was verified that no check source was available in 38% of the visited facilities; the training of personnel was not adequate in 9% of the facilities and the registry of accumulated individual doses was not being done in 6% of the facilities. Measurements of absorbed dose have indicated deviations in the range [Formula: see text] for 67.6% of the cobalt‐60 units and 79.6% of medical linear accelerators; 18.5% of Co‐60 irradiators and 9.6% of linear accelerators presented deviations in the range [Formula: see text]. Finally, 13.9% of Co‐60 facilities and 10.8% of linear accelerator facilities presented dosimetry deviations above 5%. The effort in dosimetric quality control performed by IRD/CNEN audits has yielded positive changes that make radiation treatment facilities more reliable. PACS number: 87.55.Qr
format Online
Article
Text
id pubmed-5718684
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57186842018-04-02 An analysis of the regulatory program of quality audits in radiotherapy in Brazil from 1995 to 2007 de Paiva, Eduardo da Rosa, Luiz A. R. Brito, Ricardo R. A. de Sá, Lidia V. Dovales, Ana C. M. Batista, Delano V. S. Giannoni, Ricardo A. Velasco, Alexandre F. J Appl Clin Med Phys Radiation Oncology Physics The Brazilian Institute of Radiation Protection and Dosimetry (IRD/CNEN) carried out quality assurance regulatory audits in Brazilian radiotherapy facilities from 1995 to 2007. In this work, the set of data collected from 195 radiotherapy facilities that use high‐energy photon beams are analyzed. They include results from audits in linear electron accelerators and/or Co‐60 units. The inspectors of IRD/CNEN performed the dosimetry of high‐energy radiotherapy photon beams according to the IAEA dosimetry protocols TRS 277 and TRS 398, and the values of measurements were compared to stated values. Other aspects of radiological protection were checked during on‐site audits such as calibration certification of clinical dosimeters and portable monitors, existence and use of check source, use of barometer and thermometer, individual dose registry and training of staff. It was verified that no check source was available in 38% of the visited facilities; the training of personnel was not adequate in 9% of the facilities and the registry of accumulated individual doses was not being done in 6% of the facilities. Measurements of absorbed dose have indicated deviations in the range [Formula: see text] for 67.6% of the cobalt‐60 units and 79.6% of medical linear accelerators; 18.5% of Co‐60 irradiators and 9.6% of linear accelerators presented deviations in the range [Formula: see text]. Finally, 13.9% of Co‐60 facilities and 10.8% of linear accelerator facilities presented dosimetry deviations above 5%. The effort in dosimetric quality control performed by IRD/CNEN audits has yielded positive changes that make radiation treatment facilities more reliable. PACS number: 87.55.Qr John Wiley and Sons Inc. 2011-01-30 /pmc/articles/PMC5718684/ /pubmed/21587175 http://dx.doi.org/10.1120/jacmp.v12i2.3330 Text en © 2011 The Authors. https://creativecommons.org/licenses/by/3.0/This is an open access article under the terms of the Creative Commons Attribution (https://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
de Paiva, Eduardo
da Rosa, Luiz A. R.
Brito, Ricardo R. A.
de Sá, Lidia V.
Dovales, Ana C. M.
Batista, Delano V. S.
Giannoni, Ricardo A.
Velasco, Alexandre F.
An analysis of the regulatory program of quality audits in radiotherapy in Brazil from 1995 to 2007
title An analysis of the regulatory program of quality audits in radiotherapy in Brazil from 1995 to 2007
title_full An analysis of the regulatory program of quality audits in radiotherapy in Brazil from 1995 to 2007
title_fullStr An analysis of the regulatory program of quality audits in radiotherapy in Brazil from 1995 to 2007
title_full_unstemmed An analysis of the regulatory program of quality audits in radiotherapy in Brazil from 1995 to 2007
title_short An analysis of the regulatory program of quality audits in radiotherapy in Brazil from 1995 to 2007
title_sort analysis of the regulatory program of quality audits in radiotherapy in brazil from 1995 to 2007
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5718684/
https://www.ncbi.nlm.nih.gov/pubmed/21587175
http://dx.doi.org/10.1120/jacmp.v12i2.3330
work_keys_str_mv AT depaivaeduardo ananalysisoftheregulatoryprogramofqualityauditsinradiotherapyinbrazilfrom1995to2007
AT darosaluizar ananalysisoftheregulatoryprogramofqualityauditsinradiotherapyinbrazilfrom1995to2007
AT britoricardora ananalysisoftheregulatoryprogramofqualityauditsinradiotherapyinbrazilfrom1995to2007
AT desalidiav ananalysisoftheregulatoryprogramofqualityauditsinradiotherapyinbrazilfrom1995to2007
AT dovalesanacm ananalysisoftheregulatoryprogramofqualityauditsinradiotherapyinbrazilfrom1995to2007
AT batistadelanovs ananalysisoftheregulatoryprogramofqualityauditsinradiotherapyinbrazilfrom1995to2007
AT giannoniricardoa ananalysisoftheregulatoryprogramofqualityauditsinradiotherapyinbrazilfrom1995to2007
AT velascoalexandref ananalysisoftheregulatoryprogramofqualityauditsinradiotherapyinbrazilfrom1995to2007
AT depaivaeduardo analysisoftheregulatoryprogramofqualityauditsinradiotherapyinbrazilfrom1995to2007
AT darosaluizar analysisoftheregulatoryprogramofqualityauditsinradiotherapyinbrazilfrom1995to2007
AT britoricardora analysisoftheregulatoryprogramofqualityauditsinradiotherapyinbrazilfrom1995to2007
AT desalidiav analysisoftheregulatoryprogramofqualityauditsinradiotherapyinbrazilfrom1995to2007
AT dovalesanacm analysisoftheregulatoryprogramofqualityauditsinradiotherapyinbrazilfrom1995to2007
AT batistadelanovs analysisoftheregulatoryprogramofqualityauditsinradiotherapyinbrazilfrom1995to2007
AT giannoniricardoa analysisoftheregulatoryprogramofqualityauditsinradiotherapyinbrazilfrom1995to2007
AT velascoalexandref analysisoftheregulatoryprogramofqualityauditsinradiotherapyinbrazilfrom1995to2007