Cargando…

The effect of gantry spacing resolution on plan quality in a single modulated arc optimization

Volumetric‐modulated arc technique (VMAT) is an efficient form of IMRT delivery. It is advantageous over conventional IMRT in terms of treatment delivery time. This study investigates the relation between the number of segments and plan quality in VMAT optimization for a single modulated arc. Five p...

Descripción completa

Detalles Bibliográficos
Autores principales: Mihaylov, Ivaylo B., Curran, Bruce, Sternick, Edward
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5718730/
https://www.ncbi.nlm.nih.gov/pubmed/22089019
http://dx.doi.org/10.1120/jacmp.v12i4.3603
_version_ 1783284372316618752
author Mihaylov, Ivaylo B.
Curran, Bruce
Sternick, Edward
author_facet Mihaylov, Ivaylo B.
Curran, Bruce
Sternick, Edward
author_sort Mihaylov, Ivaylo B.
collection PubMed
description Volumetric‐modulated arc technique (VMAT) is an efficient form of IMRT delivery. It is advantageous over conventional IMRT in terms of treatment delivery time. This study investigates the relation between the number of segments and plan quality in VMAT optimization for a single modulated arc. Five prostate, five lung, and five head‐and‐neck (HN) patient plans were studied retrospectively. For each case, four VMAT plans were generated. The plans differed only in the number of control points used in the optimization process. The control points were spaced 2°, 3°, 4°, and 6° apart, respectively. All of the optimization parameters were the same among the four schemes. The 2° spacing plan was used as a reference to which the other three plans were compared. The plan quality was assessed by comparison of dose indices (DIs) and generalized equivalent uniform doses (gEUDs) for targets and critical structures. All optimization schemes generated clinically acceptable plans. The differences between the majority of reference and compared DIs and gEUDs were within 3%. DIs and gEUDs which differed in excess of 3% corresponded to dose levels well below the organ tolerances. The DI and the gEUD differences increased with an increase in plan complexity from prostates to HNs. Optimization with gantry spacing resolution of 4° seems to be a very balanced alternative between plan quality and plan complexity. PACS number: 87.55.de
format Online
Article
Text
id pubmed-5718730
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57187302018-04-02 The effect of gantry spacing resolution on plan quality in a single modulated arc optimization Mihaylov, Ivaylo B. Curran, Bruce Sternick, Edward J Appl Clin Med Phys Radiation Oncology Physics Volumetric‐modulated arc technique (VMAT) is an efficient form of IMRT delivery. It is advantageous over conventional IMRT in terms of treatment delivery time. This study investigates the relation between the number of segments and plan quality in VMAT optimization for a single modulated arc. Five prostate, five lung, and five head‐and‐neck (HN) patient plans were studied retrospectively. For each case, four VMAT plans were generated. The plans differed only in the number of control points used in the optimization process. The control points were spaced 2°, 3°, 4°, and 6° apart, respectively. All of the optimization parameters were the same among the four schemes. The 2° spacing plan was used as a reference to which the other three plans were compared. The plan quality was assessed by comparison of dose indices (DIs) and generalized equivalent uniform doses (gEUDs) for targets and critical structures. All optimization schemes generated clinically acceptable plans. The differences between the majority of reference and compared DIs and gEUDs were within 3%. DIs and gEUDs which differed in excess of 3% corresponded to dose levels well below the organ tolerances. The DI and the gEUD differences increased with an increase in plan complexity from prostates to HNs. Optimization with gantry spacing resolution of 4° seems to be a very balanced alternative between plan quality and plan complexity. PACS number: 87.55.de John Wiley and Sons Inc. 2011-11-15 /pmc/articles/PMC5718730/ /pubmed/22089019 http://dx.doi.org/10.1120/jacmp.v12i4.3603 Text en © 2011 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Mihaylov, Ivaylo B.
Curran, Bruce
Sternick, Edward
The effect of gantry spacing resolution on plan quality in a single modulated arc optimization
title The effect of gantry spacing resolution on plan quality in a single modulated arc optimization
title_full The effect of gantry spacing resolution on plan quality in a single modulated arc optimization
title_fullStr The effect of gantry spacing resolution on plan quality in a single modulated arc optimization
title_full_unstemmed The effect of gantry spacing resolution on plan quality in a single modulated arc optimization
title_short The effect of gantry spacing resolution on plan quality in a single modulated arc optimization
title_sort effect of gantry spacing resolution on plan quality in a single modulated arc optimization
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5718730/
https://www.ncbi.nlm.nih.gov/pubmed/22089019
http://dx.doi.org/10.1120/jacmp.v12i4.3603
work_keys_str_mv AT mihaylovivaylob theeffectofgantryspacingresolutiononplanqualityinasinglemodulatedarcoptimization
AT curranbruce theeffectofgantryspacingresolutiononplanqualityinasinglemodulatedarcoptimization
AT sternickedward theeffectofgantryspacingresolutiononplanqualityinasinglemodulatedarcoptimization
AT mihaylovivaylob effectofgantryspacingresolutiononplanqualityinasinglemodulatedarcoptimization
AT curranbruce effectofgantryspacingresolutiononplanqualityinasinglemodulatedarcoptimization
AT sternickedward effectofgantryspacingresolutiononplanqualityinasinglemodulatedarcoptimization