The aim of the present study was to evaluate the clinical efficacy of the single‐shot dual‐energy subtraction technique for obtaining portal images. We prepared two storage phosphor plates for this study. A 1 mm thick tungsten sheet was placed between the two storage phosphor plates. A single use of...

Descripción completa

Detalles Bibliográficos
Autores principales: Fujita, Hideki, Morimi, Sakon, Yamaguchi, Michihiro, Fukuda, Haruyuki, Murase, Kenya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5718733/
https://www.ncbi.nlm.nih.gov/pubmed/22088998
http://dx.doi.org/10.1120/jacmp.v12i4.3232
_version_ 1783284373074739200
author Fujita, Hideki
Morimi, Sakon
Yamaguchi, Michihiro
Fukuda, Haruyuki
Murase, Kenya
author_facet Fujita, Hideki
Morimi, Sakon
Yamaguchi, Michihiro
Fukuda, Haruyuki
Murase, Kenya
author_sort Fujita, Hideki
collection PubMed
description The aim of the present study was to evaluate the clinical efficacy of the single‐shot dual‐energy subtraction technique for obtaining portal images. We prepared two storage phosphor plates for this study. A 1 mm thick tungsten sheet was placed between the two storage phosphor plates. A single use of the double‐exposure technique provides two portal images simultaneously (i.e., a standard image and a low‐contrast image), using the same patient position and with no additional radiation delivered to the patient. A bone‐enhanced image is created by image subtraction between these two images. For evaluation of clinical efficacy, three treatment sites — the brain, lung, and pelvis — were imaged. Ten sets of images were obtained for each site, and five landmarks were selected for each treatment site. The visibility of each landmark and the ease of overall verification for the selected treatment sites were assessed separately for the standard and bone‐enhanced images. Four observers consisting of one radiation oncologist and three radiation therapists participated in the present study. For most of the landmarks studied, the bone‐enhanced images were significantly superior to the standard images. Regarding the ease of overall verification, the bone‐enhanced images were significantly superior to the standard images at all sites. The p‐values of mean rating for the brain, lung, and pelvis were 0.002, 0.012, and 0.003, respectively. The bone‐enhanced images obtained using our technique increased the image quality in terms of bone visibility, and are considered useful for routine clinical practice. PACS number: 87.56.Da
format Online
Article
Text
id pubmed-5718733
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57187332018-04-02 Effectiveness of the single‐shot dual‐energy subtraction technique for portal images Fujita, Hideki Morimi, Sakon Yamaguchi, Michihiro Fukuda, Haruyuki Murase, Kenya J Appl Clin Med Phys Radiation Oncology Physics The aim of the present study was to evaluate the clinical efficacy of the single‐shot dual‐energy subtraction technique for obtaining portal images. We prepared two storage phosphor plates for this study. A 1 mm thick tungsten sheet was placed between the two storage phosphor plates. A single use of the double‐exposure technique provides two portal images simultaneously (i.e., a standard image and a low‐contrast image), using the same patient position and with no additional radiation delivered to the patient. A bone‐enhanced image is created by image subtraction between these two images. For evaluation of clinical efficacy, three treatment sites — the brain, lung, and pelvis — were imaged. Ten sets of images were obtained for each site, and five landmarks were selected for each treatment site. The visibility of each landmark and the ease of overall verification for the selected treatment sites were assessed separately for the standard and bone‐enhanced images. Four observers consisting of one radiation oncologist and three radiation therapists participated in the present study. For most of the landmarks studied, the bone‐enhanced images were significantly superior to the standard images. Regarding the ease of overall verification, the bone‐enhanced images were significantly superior to the standard images at all sites. The p‐values of mean rating for the brain, lung, and pelvis were 0.002, 0.012, and 0.003, respectively. The bone‐enhanced images obtained using our technique increased the image quality in terms of bone visibility, and are considered useful for routine clinical practice. PACS number: 87.56.Da John Wiley and Sons Inc. 2011-11-15 /pmc/articles/PMC5718733/ /pubmed/22088998 http://dx.doi.org/10.1120/jacmp.v12i4.3232 Text en © 2011 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Fujita, Hideki
Morimi, Sakon
Yamaguchi, Michihiro
Fukuda, Haruyuki
Murase, Kenya
Effectiveness of the single‐shot dual‐energy subtraction technique for portal images
title Effectiveness of the single‐shot dual‐energy subtraction technique for portal images
title_full Effectiveness of the single‐shot dual‐energy subtraction technique for portal images
title_fullStr Effectiveness of the single‐shot dual‐energy subtraction technique for portal images
title_full_unstemmed Effectiveness of the single‐shot dual‐energy subtraction technique for portal images
title_short Effectiveness of the single‐shot dual‐energy subtraction technique for portal images
title_sort effectiveness of the single‐shot dual‐energy subtraction technique for portal images
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5718733/
https://www.ncbi.nlm.nih.gov/pubmed/22088998
http://dx.doi.org/10.1120/jacmp.v12i4.3232
work_keys_str_mv AT fujitahideki effectivenessofthesingleshotdualenergysubtractiontechniqueforportalimages
AT morimisakon effectivenessofthesingleshotdualenergysubtractiontechniqueforportalimages
AT yamaguchimichihiro effectivenessofthesingleshotdualenergysubtractiontechniqueforportalimages
AT fukudaharuyuki effectivenessofthesingleshotdualenergysubtractiontechniqueforportalimages
AT murasekenya effectivenessofthesingleshotdualenergysubtractiontechniqueforportalimages