Cargando…

Real‐time dose reconstruction for wedged photon beams: a generalized procedure

A practical and accurate generalized procedure to reconstruct the isocenter dose [Formula: see text] for 3D conformal radiotherapy (3DCRT) has been developed for X‐ray open beams supplied by linacs of different manufacturers and equipped with aSi electronic portal imaging devices (aSi EPIDs). This p...

Descripción completa

Detalles Bibliográficos
Autores principales: Piermattei, A., Greco, F., Fidanzio, A., Azario, L., Porcelli, A., Cilla, S., Sabatino, D., Russo, A., D'Onofrio, G., Russo, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5718746/
https://www.ncbi.nlm.nih.gov/pubmed/22089008
http://dx.doi.org/10.1120/jacmp.v12i4.3538
_version_ 1783284376981733376
author Piermattei, A.
Greco, F.
Fidanzio, A.
Azario, L.
Porcelli, A.
Cilla, S.
Sabatino, D.
Russo, A.
D'Onofrio, G.
Russo, M.
author_facet Piermattei, A.
Greco, F.
Fidanzio, A.
Azario, L.
Porcelli, A.
Cilla, S.
Sabatino, D.
Russo, A.
D'Onofrio, G.
Russo, M.
author_sort Piermattei, A.
collection PubMed
description A practical and accurate generalized procedure to reconstruct the isocenter dose [Formula: see text] for 3D conformal radiotherapy (3DCRT) has been developed for X‐ray open beams supplied by linacs of different manufacturers and equipped with aSi electronic portal imaging devices (aSi EPIDs). This paper reports an extension of the method, to be applied at the wedged X‐ray beams characterized by the wedge attenuation factor [Formula: see text]. Using water‐equivalent solid phantoms (SPs) of different thicknesses, w, and photon square fields of sizes, L, the generalized midplane doses [Formula: see text] and generalized transit signals [Formula: see text] by 38 beams of six different linacs were determined. The generalized data were fitted by surface equations and used together with the information of the ‘record & verify’ network of the centers. In this manner, for every beam, the [Formula: see text] reconstruction was obtained in about 25 seconds after the treatment. To test the in vivo dosimetric procedure, six pelvic treatments that used conformed wedged beams were carried out with three linacs of different manufacturers. For every beam, the comparison between the reconstructed [Formula: see text] and the [Formula: see text] computed by the TPS, resulted in an acceptable tolerance level of [Formula: see text] , estimated for this kind of treatment. Generally the in vivo dosimetry methods that use EPIDs require: (i) a special effort for the dosimetric commissioning with SPs of different thicknesses, and (ii) extra time for the analysis of the EPID signals. The proposed procedure simplifies the commissioning step and supplies for Varian, Elekta, and Siemens linacs equipped with the aSi EPIDs a quasi‐real time in vivo dosimetry for open and wedged 3DCRT fields. PACS number: 87.53Xd
format Online
Article
Text
id pubmed-5718746
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57187462018-04-02 Real‐time dose reconstruction for wedged photon beams: a generalized procedure Piermattei, A. Greco, F. Fidanzio, A. Azario, L. Porcelli, A. Cilla, S. Sabatino, D. Russo, A. D'Onofrio, G. Russo, M. J Appl Clin Med Phys Radiation Oncology Physics A practical and accurate generalized procedure to reconstruct the isocenter dose [Formula: see text] for 3D conformal radiotherapy (3DCRT) has been developed for X‐ray open beams supplied by linacs of different manufacturers and equipped with aSi electronic portal imaging devices (aSi EPIDs). This paper reports an extension of the method, to be applied at the wedged X‐ray beams characterized by the wedge attenuation factor [Formula: see text]. Using water‐equivalent solid phantoms (SPs) of different thicknesses, w, and photon square fields of sizes, L, the generalized midplane doses [Formula: see text] and generalized transit signals [Formula: see text] by 38 beams of six different linacs were determined. The generalized data were fitted by surface equations and used together with the information of the ‘record & verify’ network of the centers. In this manner, for every beam, the [Formula: see text] reconstruction was obtained in about 25 seconds after the treatment. To test the in vivo dosimetric procedure, six pelvic treatments that used conformed wedged beams were carried out with three linacs of different manufacturers. For every beam, the comparison between the reconstructed [Formula: see text] and the [Formula: see text] computed by the TPS, resulted in an acceptable tolerance level of [Formula: see text] , estimated for this kind of treatment. Generally the in vivo dosimetry methods that use EPIDs require: (i) a special effort for the dosimetric commissioning with SPs of different thicknesses, and (ii) extra time for the analysis of the EPID signals. The proposed procedure simplifies the commissioning step and supplies for Varian, Elekta, and Siemens linacs equipped with the aSi EPIDs a quasi‐real time in vivo dosimetry for open and wedged 3DCRT fields. PACS number: 87.53Xd John Wiley and Sons Inc. 2011-11-15 /pmc/articles/PMC5718746/ /pubmed/22089008 http://dx.doi.org/10.1120/jacmp.v12i4.3538 Text en © 2011 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Piermattei, A.
Greco, F.
Fidanzio, A.
Azario, L.
Porcelli, A.
Cilla, S.
Sabatino, D.
Russo, A.
D'Onofrio, G.
Russo, M.
Real‐time dose reconstruction for wedged photon beams: a generalized procedure
title Real‐time dose reconstruction for wedged photon beams: a generalized procedure
title_full Real‐time dose reconstruction for wedged photon beams: a generalized procedure
title_fullStr Real‐time dose reconstruction for wedged photon beams: a generalized procedure
title_full_unstemmed Real‐time dose reconstruction for wedged photon beams: a generalized procedure
title_short Real‐time dose reconstruction for wedged photon beams: a generalized procedure
title_sort real‐time dose reconstruction for wedged photon beams: a generalized procedure
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5718746/
https://www.ncbi.nlm.nih.gov/pubmed/22089008
http://dx.doi.org/10.1120/jacmp.v12i4.3538
work_keys_str_mv AT piermatteia realtimedosereconstructionforwedgedphotonbeamsageneralizedprocedure
AT grecof realtimedosereconstructionforwedgedphotonbeamsageneralizedprocedure
AT fidanzioa realtimedosereconstructionforwedgedphotonbeamsageneralizedprocedure
AT azariol realtimedosereconstructionforwedgedphotonbeamsageneralizedprocedure
AT porcellia realtimedosereconstructionforwedgedphotonbeamsageneralizedprocedure
AT cillas realtimedosereconstructionforwedgedphotonbeamsageneralizedprocedure
AT sabatinod realtimedosereconstructionforwedgedphotonbeamsageneralizedprocedure
AT russoa realtimedosereconstructionforwedgedphotonbeamsageneralizedprocedure
AT donofriog realtimedosereconstructionforwedgedphotonbeamsageneralizedprocedure
AT russom realtimedosereconstructionforwedgedphotonbeamsageneralizedprocedure