Cargando…
Real‐time dose reconstruction for wedged photon beams: a generalized procedure
A practical and accurate generalized procedure to reconstruct the isocenter dose [Formula: see text] for 3D conformal radiotherapy (3DCRT) has been developed for X‐ray open beams supplied by linacs of different manufacturers and equipped with aSi electronic portal imaging devices (aSi EPIDs). This p...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5718746/ https://www.ncbi.nlm.nih.gov/pubmed/22089008 http://dx.doi.org/10.1120/jacmp.v12i4.3538 |
_version_ | 1783284376981733376 |
---|---|
author | Piermattei, A. Greco, F. Fidanzio, A. Azario, L. Porcelli, A. Cilla, S. Sabatino, D. Russo, A. D'Onofrio, G. Russo, M. |
author_facet | Piermattei, A. Greco, F. Fidanzio, A. Azario, L. Porcelli, A. Cilla, S. Sabatino, D. Russo, A. D'Onofrio, G. Russo, M. |
author_sort | Piermattei, A. |
collection | PubMed |
description | A practical and accurate generalized procedure to reconstruct the isocenter dose [Formula: see text] for 3D conformal radiotherapy (3DCRT) has been developed for X‐ray open beams supplied by linacs of different manufacturers and equipped with aSi electronic portal imaging devices (aSi EPIDs). This paper reports an extension of the method, to be applied at the wedged X‐ray beams characterized by the wedge attenuation factor [Formula: see text]. Using water‐equivalent solid phantoms (SPs) of different thicknesses, w, and photon square fields of sizes, L, the generalized midplane doses [Formula: see text] and generalized transit signals [Formula: see text] by 38 beams of six different linacs were determined. The generalized data were fitted by surface equations and used together with the information of the ‘record & verify’ network of the centers. In this manner, for every beam, the [Formula: see text] reconstruction was obtained in about 25 seconds after the treatment. To test the in vivo dosimetric procedure, six pelvic treatments that used conformed wedged beams were carried out with three linacs of different manufacturers. For every beam, the comparison between the reconstructed [Formula: see text] and the [Formula: see text] computed by the TPS, resulted in an acceptable tolerance level of [Formula: see text] , estimated for this kind of treatment. Generally the in vivo dosimetry methods that use EPIDs require: (i) a special effort for the dosimetric commissioning with SPs of different thicknesses, and (ii) extra time for the analysis of the EPID signals. The proposed procedure simplifies the commissioning step and supplies for Varian, Elekta, and Siemens linacs equipped with the aSi EPIDs a quasi‐real time in vivo dosimetry for open and wedged 3DCRT fields. PACS number: 87.53Xd |
format | Online Article Text |
id | pubmed-5718746 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-57187462018-04-02 Real‐time dose reconstruction for wedged photon beams: a generalized procedure Piermattei, A. Greco, F. Fidanzio, A. Azario, L. Porcelli, A. Cilla, S. Sabatino, D. Russo, A. D'Onofrio, G. Russo, M. J Appl Clin Med Phys Radiation Oncology Physics A practical and accurate generalized procedure to reconstruct the isocenter dose [Formula: see text] for 3D conformal radiotherapy (3DCRT) has been developed for X‐ray open beams supplied by linacs of different manufacturers and equipped with aSi electronic portal imaging devices (aSi EPIDs). This paper reports an extension of the method, to be applied at the wedged X‐ray beams characterized by the wedge attenuation factor [Formula: see text]. Using water‐equivalent solid phantoms (SPs) of different thicknesses, w, and photon square fields of sizes, L, the generalized midplane doses [Formula: see text] and generalized transit signals [Formula: see text] by 38 beams of six different linacs were determined. The generalized data were fitted by surface equations and used together with the information of the ‘record & verify’ network of the centers. In this manner, for every beam, the [Formula: see text] reconstruction was obtained in about 25 seconds after the treatment. To test the in vivo dosimetric procedure, six pelvic treatments that used conformed wedged beams were carried out with three linacs of different manufacturers. For every beam, the comparison between the reconstructed [Formula: see text] and the [Formula: see text] computed by the TPS, resulted in an acceptable tolerance level of [Formula: see text] , estimated for this kind of treatment. Generally the in vivo dosimetry methods that use EPIDs require: (i) a special effort for the dosimetric commissioning with SPs of different thicknesses, and (ii) extra time for the analysis of the EPID signals. The proposed procedure simplifies the commissioning step and supplies for Varian, Elekta, and Siemens linacs equipped with the aSi EPIDs a quasi‐real time in vivo dosimetry for open and wedged 3DCRT fields. PACS number: 87.53Xd John Wiley and Sons Inc. 2011-11-15 /pmc/articles/PMC5718746/ /pubmed/22089008 http://dx.doi.org/10.1120/jacmp.v12i4.3538 Text en © 2011 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Piermattei, A. Greco, F. Fidanzio, A. Azario, L. Porcelli, A. Cilla, S. Sabatino, D. Russo, A. D'Onofrio, G. Russo, M. Real‐time dose reconstruction for wedged photon beams: a generalized procedure |
title | Real‐time dose reconstruction for wedged photon beams: a generalized procedure |
title_full | Real‐time dose reconstruction for wedged photon beams: a generalized procedure |
title_fullStr | Real‐time dose reconstruction for wedged photon beams: a generalized procedure |
title_full_unstemmed | Real‐time dose reconstruction for wedged photon beams: a generalized procedure |
title_short | Real‐time dose reconstruction for wedged photon beams: a generalized procedure |
title_sort | real‐time dose reconstruction for wedged photon beams: a generalized procedure |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5718746/ https://www.ncbi.nlm.nih.gov/pubmed/22089008 http://dx.doi.org/10.1120/jacmp.v12i4.3538 |
work_keys_str_mv | AT piermatteia realtimedosereconstructionforwedgedphotonbeamsageneralizedprocedure AT grecof realtimedosereconstructionforwedgedphotonbeamsageneralizedprocedure AT fidanzioa realtimedosereconstructionforwedgedphotonbeamsageneralizedprocedure AT azariol realtimedosereconstructionforwedgedphotonbeamsageneralizedprocedure AT porcellia realtimedosereconstructionforwedgedphotonbeamsageneralizedprocedure AT cillas realtimedosereconstructionforwedgedphotonbeamsageneralizedprocedure AT sabatinod realtimedosereconstructionforwedgedphotonbeamsageneralizedprocedure AT russoa realtimedosereconstructionforwedgedphotonbeamsageneralizedprocedure AT donofriog realtimedosereconstructionforwedgedphotonbeamsageneralizedprocedure AT russom realtimedosereconstructionforwedgedphotonbeamsageneralizedprocedure |