Cargando…
Arthroscopic Pullout Fixation for a Small and Comminuted Avulsion Fracture of the Posterior Cruciate Ligament from the Tibia
We describe a patient who underwent arthroscopic pullout fixation for a posterior cruciate ligament (PCL) avulsion fracture. A 46-year-old female, injured in a fall while riding a motorcycle, was diagnosed with a right knee PCL tibial attachment avulsion fracture and underwent arthroscopic osteosynt...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Knee Society
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5718800/ https://www.ncbi.nlm.nih.gov/pubmed/29172392 http://dx.doi.org/10.5792/ksrr.16.025 |
_version_ | 1783284389906481152 |
---|---|
author | Nakagawa, Shuji Arai, Yuji Hara, Kunio Inoue, Hiroaki Hino, Manabu Kubo, Toshikazu |
author_facet | Nakagawa, Shuji Arai, Yuji Hara, Kunio Inoue, Hiroaki Hino, Manabu Kubo, Toshikazu |
author_sort | Nakagawa, Shuji |
collection | PubMed |
description | We describe a patient who underwent arthroscopic pullout fixation for a posterior cruciate ligament (PCL) avulsion fracture. A 46-year-old female, injured in a fall while riding a motorcycle, was diagnosed with a right knee PCL tibial attachment avulsion fracture and underwent arthroscopic osteosynthesis. A Kirschner wire was drilled to a point just medial to the medial border of the anterior tibial bony bed. A suture wire was folded into a loop and introduced into the posteromedial compartment via the bone tunnel. A fixation thread was inserted from the posteromedial portal, through the medial and lateral loop wires, and into the posteromedial compartment. The lateral and medial loop wires attached to the thread were pulled to the outside, and the thread was fixed onto the tibia. Three months post-surgery, she returned to her job. This procedure represents a minimally invasive method of treating avulsion fractures of the tibial attachment of the PCL. |
format | Online Article Text |
id | pubmed-5718800 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Korean Knee Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-57188002017-12-12 Arthroscopic Pullout Fixation for a Small and Comminuted Avulsion Fracture of the Posterior Cruciate Ligament from the Tibia Nakagawa, Shuji Arai, Yuji Hara, Kunio Inoue, Hiroaki Hino, Manabu Kubo, Toshikazu Knee Surg Relat Res Case Report We describe a patient who underwent arthroscopic pullout fixation for a posterior cruciate ligament (PCL) avulsion fracture. A 46-year-old female, injured in a fall while riding a motorcycle, was diagnosed with a right knee PCL tibial attachment avulsion fracture and underwent arthroscopic osteosynthesis. A Kirschner wire was drilled to a point just medial to the medial border of the anterior tibial bony bed. A suture wire was folded into a loop and introduced into the posteromedial compartment via the bone tunnel. A fixation thread was inserted from the posteromedial portal, through the medial and lateral loop wires, and into the posteromedial compartment. The lateral and medial loop wires attached to the thread were pulled to the outside, and the thread was fixed onto the tibia. Three months post-surgery, she returned to her job. This procedure represents a minimally invasive method of treating avulsion fractures of the tibial attachment of the PCL. Korean Knee Society 2017-12 2017-12-01 /pmc/articles/PMC5718800/ /pubmed/29172392 http://dx.doi.org/10.5792/ksrr.16.025 Text en Copyright © 2017 Korean Knee Society This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Nakagawa, Shuji Arai, Yuji Hara, Kunio Inoue, Hiroaki Hino, Manabu Kubo, Toshikazu Arthroscopic Pullout Fixation for a Small and Comminuted Avulsion Fracture of the Posterior Cruciate Ligament from the Tibia |
title | Arthroscopic Pullout Fixation for a Small and Comminuted Avulsion Fracture of the Posterior Cruciate Ligament from the Tibia |
title_full | Arthroscopic Pullout Fixation for a Small and Comminuted Avulsion Fracture of the Posterior Cruciate Ligament from the Tibia |
title_fullStr | Arthroscopic Pullout Fixation for a Small and Comminuted Avulsion Fracture of the Posterior Cruciate Ligament from the Tibia |
title_full_unstemmed | Arthroscopic Pullout Fixation for a Small and Comminuted Avulsion Fracture of the Posterior Cruciate Ligament from the Tibia |
title_short | Arthroscopic Pullout Fixation for a Small and Comminuted Avulsion Fracture of the Posterior Cruciate Ligament from the Tibia |
title_sort | arthroscopic pullout fixation for a small and comminuted avulsion fracture of the posterior cruciate ligament from the tibia |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5718800/ https://www.ncbi.nlm.nih.gov/pubmed/29172392 http://dx.doi.org/10.5792/ksrr.16.025 |
work_keys_str_mv | AT nakagawashuji arthroscopicpulloutfixationforasmallandcomminutedavulsionfractureoftheposteriorcruciateligamentfromthetibia AT araiyuji arthroscopicpulloutfixationforasmallandcomminutedavulsionfractureoftheposteriorcruciateligamentfromthetibia AT harakunio arthroscopicpulloutfixationforasmallandcomminutedavulsionfractureoftheposteriorcruciateligamentfromthetibia AT inouehiroaki arthroscopicpulloutfixationforasmallandcomminutedavulsionfractureoftheposteriorcruciateligamentfromthetibia AT hinomanabu arthroscopicpulloutfixationforasmallandcomminutedavulsionfractureoftheposteriorcruciateligamentfromthetibia AT kubotoshikazu arthroscopicpulloutfixationforasmallandcomminutedavulsionfractureoftheposteriorcruciateligamentfromthetibia |