Cargando…

Dosimetric effects of air pocket sizes in MammoSite treatment as accelerated partial breast irradiation for early breast cancer

MammoSite brachytherapy system has been used as one of the accelerated partial breast irradiation (APBI) techniques since 2002. The clinical results from several clinical institutions had shown comparable treatment efficacy, cosmesis, and toxicity to other APBI techniques. During MammoSite treatment...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Y. Jessica, Blough, Melissa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5719773/
https://www.ncbi.nlm.nih.gov/pubmed/20160678
http://dx.doi.org/10.1120/jacmp.v11i1.2932
_version_ 1783284554570661888
author Huang, Y. Jessica
Blough, Melissa
author_facet Huang, Y. Jessica
Blough, Melissa
author_sort Huang, Y. Jessica
collection PubMed
description MammoSite brachytherapy system has been used as one of the accelerated partial breast irradiation (APBI) techniques since 2002. The clinical results from several clinical institutions had shown comparable treatment efficacy, cosmesis, and toxicity to other APBI techniques. During MammoSite treatment, air cavities had been one of the primary issues causing treatment cancellation or delay. With the tolerance of the air volume less than 10% of the total Planning Target Volume (PTV) set, there is still no data available to show the actual dose delivered to the breast tissue with the existence of the air pocket. In this paper, Monte Carlo N‐Particle version 5 (MCNP5) was used to model a hypothesis MammoSite phantom with different sizes of air pockets, and compared to the calculation results from the treatment planning system (TPS) without heterogeneous corrections. It was found that without heterogeneous corrections, the difference between the TPS and MCNP5 calculations in the air cavity surface doses and PTV point doses can be up to 2.02% and 3.61%, respectively, using the balloon and air pocket size combinations calculated in this paper. Based on the distance from the point of interest to the balloon surface, an approximate dose can be calculated using the linear relationship found in this study. These equations provide a quick and simple way to predict the actual dose delivered to the breast soft tissue located within the PTV. With the equation applied to the dose from the TPS, the dose error caused by the air pocket during MammoSite treatment can be reduced to a minimum. PACS number: 87.53.Jw
format Online
Article
Text
id pubmed-5719773
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57197732018-04-02 Dosimetric effects of air pocket sizes in MammoSite treatment as accelerated partial breast irradiation for early breast cancer Huang, Y. Jessica Blough, Melissa J Appl Clin Med Phys Radiation Oncology Physics MammoSite brachytherapy system has been used as one of the accelerated partial breast irradiation (APBI) techniques since 2002. The clinical results from several clinical institutions had shown comparable treatment efficacy, cosmesis, and toxicity to other APBI techniques. During MammoSite treatment, air cavities had been one of the primary issues causing treatment cancellation or delay. With the tolerance of the air volume less than 10% of the total Planning Target Volume (PTV) set, there is still no data available to show the actual dose delivered to the breast tissue with the existence of the air pocket. In this paper, Monte Carlo N‐Particle version 5 (MCNP5) was used to model a hypothesis MammoSite phantom with different sizes of air pockets, and compared to the calculation results from the treatment planning system (TPS) without heterogeneous corrections. It was found that without heterogeneous corrections, the difference between the TPS and MCNP5 calculations in the air cavity surface doses and PTV point doses can be up to 2.02% and 3.61%, respectively, using the balloon and air pocket size combinations calculated in this paper. Based on the distance from the point of interest to the balloon surface, an approximate dose can be calculated using the linear relationship found in this study. These equations provide a quick and simple way to predict the actual dose delivered to the breast soft tissue located within the PTV. With the equation applied to the dose from the TPS, the dose error caused by the air pocket during MammoSite treatment can be reduced to a minimum. PACS number: 87.53.Jw John Wiley and Sons Inc. 2009-12-23 /pmc/articles/PMC5719773/ /pubmed/20160678 http://dx.doi.org/10.1120/jacmp.v11i1.2932 Text en © 2010 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Huang, Y. Jessica
Blough, Melissa
Dosimetric effects of air pocket sizes in MammoSite treatment as accelerated partial breast irradiation for early breast cancer
title Dosimetric effects of air pocket sizes in MammoSite treatment as accelerated partial breast irradiation for early breast cancer
title_full Dosimetric effects of air pocket sizes in MammoSite treatment as accelerated partial breast irradiation for early breast cancer
title_fullStr Dosimetric effects of air pocket sizes in MammoSite treatment as accelerated partial breast irradiation for early breast cancer
title_full_unstemmed Dosimetric effects of air pocket sizes in MammoSite treatment as accelerated partial breast irradiation for early breast cancer
title_short Dosimetric effects of air pocket sizes in MammoSite treatment as accelerated partial breast irradiation for early breast cancer
title_sort dosimetric effects of air pocket sizes in mammosite treatment as accelerated partial breast irradiation for early breast cancer
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5719773/
https://www.ncbi.nlm.nih.gov/pubmed/20160678
http://dx.doi.org/10.1120/jacmp.v11i1.2932
work_keys_str_mv AT huangyjessica dosimetriceffectsofairpocketsizesinmammositetreatmentasacceleratedpartialbreastirradiationforearlybreastcancer
AT bloughmelissa dosimetriceffectsofairpocketsizesinmammositetreatmentasacceleratedpartialbreastirradiationforearlybreastcancer