Investigation of a 3D system distortion correction method for MR images
Interest has been growing in recent years in the development of radiation treatment planning (RTP) techniques based solely on magnetic resonance (MR) images. However, it is recognized that MR images suffer from scanner‐related and object‐induced distortions that may lead to an incorrect placement of...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5719775/ https://www.ncbi.nlm.nih.gov/pubmed/20160688 http://dx.doi.org/10.1120/jacmp.v11i1.2961 |
_version_ | 1783284555056152576 |
---|---|
author | Stanescu, Teodor Jans, Hans‐Sonke Wachowicz, Keith Fallone, B. Gino |
author_facet | Stanescu, Teodor Jans, Hans‐Sonke Wachowicz, Keith Fallone, B. Gino |
author_sort | Stanescu, Teodor |
collection | PubMed |
description | Interest has been growing in recent years in the development of radiation treatment planning (RTP) techniques based solely on magnetic resonance (MR) images. However, it is recognized that MR images suffer from scanner‐related and object‐induced distortions that may lead to an incorrect placement of anatomical structures. This subsequently may result in reduced accuracy in delivering treatment dose fractions in RTP. To accomplish the accurate representation of anatomical targets required by RTP, distortions must be mapped and the images rectified before being used in the clinical process. In this work, we investigate a novel, phantom‐based method that determines and corrects for 3D system‐related distortions. The algorithm consists of two key components: an adaptive control point identification and registration tool and an iterative method that finds the best estimate of 3D distortion. It was found that the 3D distortions were successfully mapped to within the voxel resolution of the raw data for a [Formula: see text] volume. PACS numbers: 87.61.‐c, 87.53.Tf, 87.53.Xd, 87.56.‐v, 87.56.Fc, 87.62.+n |
format | Online Article Text |
id | pubmed-5719775 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-57197752018-04-02 Investigation of a 3D system distortion correction method for MR images Stanescu, Teodor Jans, Hans‐Sonke Wachowicz, Keith Fallone, B. Gino J Appl Clin Med Phys Medical Imaging Interest has been growing in recent years in the development of radiation treatment planning (RTP) techniques based solely on magnetic resonance (MR) images. However, it is recognized that MR images suffer from scanner‐related and object‐induced distortions that may lead to an incorrect placement of anatomical structures. This subsequently may result in reduced accuracy in delivering treatment dose fractions in RTP. To accomplish the accurate representation of anatomical targets required by RTP, distortions must be mapped and the images rectified before being used in the clinical process. In this work, we investigate a novel, phantom‐based method that determines and corrects for 3D system‐related distortions. The algorithm consists of two key components: an adaptive control point identification and registration tool and an iterative method that finds the best estimate of 3D distortion. It was found that the 3D distortions were successfully mapped to within the voxel resolution of the raw data for a [Formula: see text] volume. PACS numbers: 87.61.‐c, 87.53.Tf, 87.53.Xd, 87.56.‐v, 87.56.Fc, 87.62.+n John Wiley and Sons Inc. 2010-01-28 /pmc/articles/PMC5719775/ /pubmed/20160688 http://dx.doi.org/10.1120/jacmp.v11i1.2961 Text en © 2010 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Medical Imaging Stanescu, Teodor Jans, Hans‐Sonke Wachowicz, Keith Fallone, B. Gino Investigation of a 3D system distortion correction method for MR images |
title | Investigation of a 3D system distortion correction method for MR images |
title_full | Investigation of a 3D system distortion correction method for MR images |
title_fullStr | Investigation of a 3D system distortion correction method for MR images |
title_full_unstemmed | Investigation of a 3D system distortion correction method for MR images |
title_short | Investigation of a 3D system distortion correction method for MR images |
title_sort | investigation of a 3d system distortion correction method for mr images |
topic | Medical Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5719775/ https://www.ncbi.nlm.nih.gov/pubmed/20160688 http://dx.doi.org/10.1120/jacmp.v11i1.2961 |
work_keys_str_mv | AT stanescuteodor investigationofa3dsystemdistortioncorrectionmethodformrimages AT janshanssonke investigationofa3dsystemdistortioncorrectionmethodformrimages AT wachowiczkeith investigationofa3dsystemdistortioncorrectionmethodformrimages AT fallonebgino investigationofa3dsystemdistortioncorrectionmethodformrimages |