Cargando…

Angular dose dependency of MatriXX TM and its calibration

One of the applications of MatriXX (IBA Dosimetry) is experimental verification of dose for IMRT, VMAT, and tomotherapy. For cumulative plan verification, dose is delivered for all the treatment gantry angles to a stationary detector. Experimental calibration of MatriXX detector recommended by the m...

Descripción completa

Detalles Bibliográficos
Autores principales: Wolfsberger, Luciant D., Wagar, Matthew, Nitsch, Paige, Bhagwat, Mandar S., Zygmanski, Piotr
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5719776/
https://www.ncbi.nlm.nih.gov/pubmed/20160692
http://dx.doi.org/10.1120/jacmp.v11i1.3057
_version_ 1783284555300470784
author Wolfsberger, Luciant D.
Wagar, Matthew
Nitsch, Paige
Bhagwat, Mandar S.
Zygmanski, Piotr
author_facet Wolfsberger, Luciant D.
Wagar, Matthew
Nitsch, Paige
Bhagwat, Mandar S.
Zygmanski, Piotr
author_sort Wolfsberger, Luciant D.
collection PubMed
description One of the applications of MatriXX (IBA Dosimetry) is experimental verification of dose for IMRT, VMAT, and tomotherapy. For cumulative plan verification, dose is delivered for all the treatment gantry angles to a stationary detector. Experimental calibration of MatriXX detector recommended by the manufacturer involves only AP calibration fields and does not address angular dependency of MatriXX. Angular dependency may introduce dose bias in cumulative plan verification if not corrected. For this reason, we characterized angular dependency of MatriXX and developed a method for its calibration. We found relatively large discrepancies in responses to posterior vs. anterior fields for four MatriXX (Evolution series) detectors (up to 11%), and relatively large variability of responses as a function of gantry angle in the gantry angle ranges of 91°–110° and 269°–260°. With our calibration method, the bias due to angular dependency is effectively removed in experimental verification of IMRT and VMAT plans. PACS number: 87.56Fc
format Online
Article
Text
id pubmed-5719776
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57197762018-04-02 Angular dose dependency of MatriXX TM and its calibration Wolfsberger, Luciant D. Wagar, Matthew Nitsch, Paige Bhagwat, Mandar S. Zygmanski, Piotr J Appl Clin Med Phys Radiation Measurements One of the applications of MatriXX (IBA Dosimetry) is experimental verification of dose for IMRT, VMAT, and tomotherapy. For cumulative plan verification, dose is delivered for all the treatment gantry angles to a stationary detector. Experimental calibration of MatriXX detector recommended by the manufacturer involves only AP calibration fields and does not address angular dependency of MatriXX. Angular dependency may introduce dose bias in cumulative plan verification if not corrected. For this reason, we characterized angular dependency of MatriXX and developed a method for its calibration. We found relatively large discrepancies in responses to posterior vs. anterior fields for four MatriXX (Evolution series) detectors (up to 11%), and relatively large variability of responses as a function of gantry angle in the gantry angle ranges of 91°–110° and 269°–260°. With our calibration method, the bias due to angular dependency is effectively removed in experimental verification of IMRT and VMAT plans. PACS number: 87.56Fc John Wiley and Sons Inc. 2010-01-28 /pmc/articles/PMC5719776/ /pubmed/20160692 http://dx.doi.org/10.1120/jacmp.v11i1.3057 Text en © 2010 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Measurements
Wolfsberger, Luciant D.
Wagar, Matthew
Nitsch, Paige
Bhagwat, Mandar S.
Zygmanski, Piotr
Angular dose dependency of MatriXX TM and its calibration
title Angular dose dependency of MatriXX TM and its calibration
title_full Angular dose dependency of MatriXX TM and its calibration
title_fullStr Angular dose dependency of MatriXX TM and its calibration
title_full_unstemmed Angular dose dependency of MatriXX TM and its calibration
title_short Angular dose dependency of MatriXX TM and its calibration
title_sort angular dose dependency of matrixx tm and its calibration
topic Radiation Measurements
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5719776/
https://www.ncbi.nlm.nih.gov/pubmed/20160692
http://dx.doi.org/10.1120/jacmp.v11i1.3057
work_keys_str_mv AT wolfsbergerluciantd angulardosedependencyofmatrixxtmanditscalibration
AT wagarmatthew angulardosedependencyofmatrixxtmanditscalibration
AT nitschpaige angulardosedependencyofmatrixxtmanditscalibration
AT bhagwatmandars angulardosedependencyofmatrixxtmanditscalibration
AT zygmanskipiotr angulardosedependencyofmatrixxtmanditscalibration