Cargando…

Evaluation of Ternary Mobile Phases for the Analysis of Carbonyl Compound Derivatives Using High-Performance Liquid Chromatography

In this study, the feasibility of ternary mobile phases was examined in a high-performance liquid chromatography (HPLC)-based analysis of carbonyl compounds (CCs). To test the performance of different ternary phases, the liquid phase standards containing a 15 aldehyde/ketone-DNPH(o) mix were analyze...

Descripción completa

Detalles Bibliográficos
Autores principales: Ho, Duy Xuan, Kim, Ki-Hyun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: TheScientificWorldJOURNAL 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5719991/
https://www.ncbi.nlm.nih.gov/pubmed/21218260
http://dx.doi.org/10.1100/tsw.2011.4
_version_ 1783284593556717568
author Ho, Duy Xuan
Kim, Ki-Hyun
author_facet Ho, Duy Xuan
Kim, Ki-Hyun
author_sort Ho, Duy Xuan
collection PubMed
description In this study, the feasibility of ternary mobile phases was examined in a high-performance liquid chromatography (HPLC)-based analysis of carbonyl compounds (CCs). To test the performance of different ternary phases, the liquid phase standards containing a 15 aldehyde/ketone-DNPH(o) mix were analyzed through a series of five-point calibration experiments. For this comparison, three types of ternary mobile phases were prepared initially by mixing water (W) with two of the following three organic solvents: isopropanol (I), methanol (M), and tetrahydrofuran (T). The resulting three types of ternary phases (named as WIM, WTM, and WIT) were tested and evaluated in relation to the water content or in terms of methanol-to-water ratio (M/W). The results derived by the three ternary phases revealed that the optimal resolution was attained near maximum water content, while those of WIT consistently suffered from poor resolution problems. The relative performances of WIM and WTM phases, if assessed by three key operating parameters (sensitivity, retention time, and resolution), were found to be reliable for most selected CCs with the decreasing M/W ratio.
format Online
Article
Text
id pubmed-5719991
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher TheScientificWorldJOURNAL
record_format MEDLINE/PubMed
spelling pubmed-57199912017-12-21 Evaluation of Ternary Mobile Phases for the Analysis of Carbonyl Compound Derivatives Using High-Performance Liquid Chromatography Ho, Duy Xuan Kim, Ki-Hyun ScientificWorldJournal Research Article In this study, the feasibility of ternary mobile phases was examined in a high-performance liquid chromatography (HPLC)-based analysis of carbonyl compounds (CCs). To test the performance of different ternary phases, the liquid phase standards containing a 15 aldehyde/ketone-DNPH(o) mix were analyzed through a series of five-point calibration experiments. For this comparison, three types of ternary mobile phases were prepared initially by mixing water (W) with two of the following three organic solvents: isopropanol (I), methanol (M), and tetrahydrofuran (T). The resulting three types of ternary phases (named as WIM, WTM, and WIT) were tested and evaluated in relation to the water content or in terms of methanol-to-water ratio (M/W). The results derived by the three ternary phases revealed that the optimal resolution was attained near maximum water content, while those of WIT consistently suffered from poor resolution problems. The relative performances of WIM and WTM phases, if assessed by three key operating parameters (sensitivity, retention time, and resolution), were found to be reliable for most selected CCs with the decreasing M/W ratio. TheScientificWorldJOURNAL 2011-01-05 /pmc/articles/PMC5719991/ /pubmed/21218260 http://dx.doi.org/10.1100/tsw.2011.4 Text en Copyright © 2011 Duy Ho and Ki-Hyun Kim. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Ho, Duy Xuan
Kim, Ki-Hyun
Evaluation of Ternary Mobile Phases for the Analysis of Carbonyl Compound Derivatives Using High-Performance Liquid Chromatography
title Evaluation of Ternary Mobile Phases for the Analysis of Carbonyl Compound Derivatives Using High-Performance Liquid Chromatography
title_full Evaluation of Ternary Mobile Phases for the Analysis of Carbonyl Compound Derivatives Using High-Performance Liquid Chromatography
title_fullStr Evaluation of Ternary Mobile Phases for the Analysis of Carbonyl Compound Derivatives Using High-Performance Liquid Chromatography
title_full_unstemmed Evaluation of Ternary Mobile Phases for the Analysis of Carbonyl Compound Derivatives Using High-Performance Liquid Chromatography
title_short Evaluation of Ternary Mobile Phases for the Analysis of Carbonyl Compound Derivatives Using High-Performance Liquid Chromatography
title_sort evaluation of ternary mobile phases for the analysis of carbonyl compound derivatives using high-performance liquid chromatography
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5719991/
https://www.ncbi.nlm.nih.gov/pubmed/21218260
http://dx.doi.org/10.1100/tsw.2011.4
work_keys_str_mv AT hoduyxuan evaluationofternarymobilephasesfortheanalysisofcarbonylcompoundderivativesusinghighperformanceliquidchromatography
AT kimkihyun evaluationofternarymobilephasesfortheanalysisofcarbonylcompoundderivativesusinghighperformanceliquidchromatography