Cargando…

Emission Rate of Particulate Matter and Its Removal Efficiency by Precipitators in Under-Fired Charbroiling Restaurants

In order to explore the potent role of meat cooking processes as the emission sources of particulate matter (PM), emission rates and the associated removal efficiency by precipitators were estimated based on the on-site measurements made at five under-fired charbroiling (UFC) restaurants. The emissi...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Jun-Bok, Kim, Ki-Hyun, Kim, Heung-Joo, Cho, Seog-Ju, Jung, Kweon, Kim, Shin-Do
Formato: Online Artículo Texto
Lenguaje:English
Publicado: TheScientificWorldJOURNAL 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720053/
https://www.ncbi.nlm.nih.gov/pubmed/21623453
http://dx.doi.org/10.1100/tsw.2011.103
_version_ 1783284608896335872
author Lee, Jun-Bok
Kim, Ki-Hyun
Kim, Heung-Joo
Cho, Seog-Ju
Jung, Kweon
Kim, Shin-Do
author_facet Lee, Jun-Bok
Kim, Ki-Hyun
Kim, Heung-Joo
Cho, Seog-Ju
Jung, Kweon
Kim, Shin-Do
author_sort Lee, Jun-Bok
collection PubMed
description In order to explore the potent role of meat cooking processes as the emission sources of particulate matter (PM), emission rates and the associated removal efficiency by precipitators were estimated based on the on-site measurements made at five under-fired charbroiling (UFC) restaurants. The emission patterns of PM for these five restaurants were compared after having been sorted into the main meat types used for cooking: beef (B), chicken (C), intestines (I), and pork (P: two sites). The mass concentrations (μg m(-3)) of three PM fractions (PM(2.5)/PM(10)/TSP) measured from these restaurants were 15,510/15,701/17,175 (C); 8,525/10,760/12,676 (B); 11,027/13,249/13,488 (P); and 22,409/22,412/22,414 (I). Emission factors (g kg(-1)) for those PM fractions were also estimated as 3.23/4.08/4.80 (B), 3.07/3.82/3.87 (P), 8.12/8.22/8.99 (C), and 6.59/6.59/6.59 (I). If the annual emission rate of PM(10) is extrapolated by combining its emission factor, population, activity factor, etc., it is estimated as 500 ton year(-1), which corresponds to 2.4% of the PM(10) budget in Seoul, Korea. Removal efficiencies of PM(10) via precipitators, such as an electrostatic precipitator (ESP), bag filter (BF), and the combination system (ESP + catalyst), installed in those UFC restaurants ranged between 54.76 and 98.98%. The removal efficiency of PM by this control system was the least effective for particles with <0.4 μm, although those in the range of 0.4–10 μm were the most effective.
format Online
Article
Text
id pubmed-5720053
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher TheScientificWorldJOURNAL
record_format MEDLINE/PubMed
spelling pubmed-57200532017-12-21 Emission Rate of Particulate Matter and Its Removal Efficiency by Precipitators in Under-Fired Charbroiling Restaurants Lee, Jun-Bok Kim, Ki-Hyun Kim, Heung-Joo Cho, Seog-Ju Jung, Kweon Kim, Shin-Do ScientificWorldJournal Research Article In order to explore the potent role of meat cooking processes as the emission sources of particulate matter (PM), emission rates and the associated removal efficiency by precipitators were estimated based on the on-site measurements made at five under-fired charbroiling (UFC) restaurants. The emission patterns of PM for these five restaurants were compared after having been sorted into the main meat types used for cooking: beef (B), chicken (C), intestines (I), and pork (P: two sites). The mass concentrations (μg m(-3)) of three PM fractions (PM(2.5)/PM(10)/TSP) measured from these restaurants were 15,510/15,701/17,175 (C); 8,525/10,760/12,676 (B); 11,027/13,249/13,488 (P); and 22,409/22,412/22,414 (I). Emission factors (g kg(-1)) for those PM fractions were also estimated as 3.23/4.08/4.80 (B), 3.07/3.82/3.87 (P), 8.12/8.22/8.99 (C), and 6.59/6.59/6.59 (I). If the annual emission rate of PM(10) is extrapolated by combining its emission factor, population, activity factor, etc., it is estimated as 500 ton year(-1), which corresponds to 2.4% of the PM(10) budget in Seoul, Korea. Removal efficiencies of PM(10) via precipitators, such as an electrostatic precipitator (ESP), bag filter (BF), and the combination system (ESP + catalyst), installed in those UFC restaurants ranged between 54.76 and 98.98%. The removal efficiency of PM by this control system was the least effective for particles with <0.4 μm, although those in the range of 0.4–10 μm were the most effective. TheScientificWorldJOURNAL 2011-05-26 /pmc/articles/PMC5720053/ /pubmed/21623453 http://dx.doi.org/10.1100/tsw.2011.103 Text en Copyright © 2011 Jun-Bok Lee et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Lee, Jun-Bok
Kim, Ki-Hyun
Kim, Heung-Joo
Cho, Seog-Ju
Jung, Kweon
Kim, Shin-Do
Emission Rate of Particulate Matter and Its Removal Efficiency by Precipitators in Under-Fired Charbroiling Restaurants
title Emission Rate of Particulate Matter and Its Removal Efficiency by Precipitators in Under-Fired Charbroiling Restaurants
title_full Emission Rate of Particulate Matter and Its Removal Efficiency by Precipitators in Under-Fired Charbroiling Restaurants
title_fullStr Emission Rate of Particulate Matter and Its Removal Efficiency by Precipitators in Under-Fired Charbroiling Restaurants
title_full_unstemmed Emission Rate of Particulate Matter and Its Removal Efficiency by Precipitators in Under-Fired Charbroiling Restaurants
title_short Emission Rate of Particulate Matter and Its Removal Efficiency by Precipitators in Under-Fired Charbroiling Restaurants
title_sort emission rate of particulate matter and its removal efficiency by precipitators in under-fired charbroiling restaurants
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720053/
https://www.ncbi.nlm.nih.gov/pubmed/21623453
http://dx.doi.org/10.1100/tsw.2011.103
work_keys_str_mv AT leejunbok emissionrateofparticulatematteranditsremovalefficiencybyprecipitatorsinunderfiredcharbroilingrestaurants
AT kimkihyun emissionrateofparticulatematteranditsremovalefficiencybyprecipitatorsinunderfiredcharbroilingrestaurants
AT kimheungjoo emissionrateofparticulatematteranditsremovalefficiencybyprecipitatorsinunderfiredcharbroilingrestaurants
AT choseogju emissionrateofparticulatematteranditsremovalefficiencybyprecipitatorsinunderfiredcharbroilingrestaurants
AT jungkweon emissionrateofparticulatematteranditsremovalefficiencybyprecipitatorsinunderfiredcharbroilingrestaurants
AT kimshindo emissionrateofparticulatematteranditsremovalefficiencybyprecipitatorsinunderfiredcharbroilingrestaurants