Breast in vivo dosimetry by EPID

An electronic portal imaging device (EPID) is an effective detector for in vivo transit dosimetry. In fact, it supplies two‐dimensional information, does not require special efforts to be used during patient treatment, and can supply data in real time. In the present paper, a new procedure has been...

Descripción completa

Detalles Bibliográficos
Autores principales: Fidanzio, Andrea, Greco, Francesca, Mameli, Alessandra, Azario, Luigi, Balducci, Mario, Gambacorta, Maria Antonietta, Frascino, Vincenzo, Cilla, Savino, Sabatino, Domenico, Piermattei, Angelo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720411/
https://www.ncbi.nlm.nih.gov/pubmed/21081886
http://dx.doi.org/10.1120/jacmp.v11i4.3275
Descripción
Sumario:An electronic portal imaging device (EPID) is an effective detector for in vivo transit dosimetry. In fact, it supplies two‐dimensional information, does not require special efforts to be used during patient treatment, and can supply data in real time. In the present paper, a new procedure has been proposed to improve the EPID in vivo dosimetry accuracy by taking into account the patient setup variations. The procedure was applied to the breast tangential irradiation for the reconstruction of the dose at the breast midpoint, [Formula: see text]. In particular, the patient setup variations were accounted for by comparing EPID images versus digitally reconstructed radiographies. In this manner, EPID transit signals were obtained corresponding to the geometrical projections of the breast midpoint on the EPID for each therapy session. At the end, the ratios R between [Formula: see text] and the doses computed by the treatment planning system (TPS) at breast midpoints, [Formula: see text] , were determined for 800 therapy sessions of 20 patients. Taking into account the method uncertainty, tolerance levels equal to [Formula: see text] have been determined for the ratio R. The improvement of in vivo dosimetry results obtained (taking into account patient misalignment) has been pointed out comparing the R values obtained with and without considering patient setup variations. In particular, when patient misalignments were taken into account, the R values were within [Formula: see text] for 93% of the checks; when patient setup variations were not taken into account, the R values were within [Formula: see text] in 72% of the checks. This last result points out that the transit dosimetry method overestimates the dose discrepancies if patient setup variations are not taken into account for dose reconstruction. In this case, larger tolerance levels have to be adopted as a trade‐off between workload and ability to detect errors, with the drawback being that some errors (such as the ones in TPS implementation or in beam calibration) cannot be detected, limiting the in vivo dosimetry efficacy. The paper also reports preliminary results about the possibility of reconstructing a dose profile perpendicular to the beam central axis reaching from the apex to the lung and passing through the middle point of the breast by an algorithm, similar to the one used for dose reconstruction at breast midpoint. In particular, the results have shown an accuracy within [Formula: see text] for the dose profile reconstructed in the breast (excluding the interface regions) and an underestimation of the lung dose. PACS numbers: 87.55.Qr, 87.55.km, 87.53.Bn