Cargando…

Dosimetric comparison study between intensity modulated radiation therapy and three‐dimensional conformal proton therapy for pelvic bone marrow sparing in the treatment of cervical cancer

The objective was to compare intensity‐modulated radiation therapy (IMRT) with 3D conformal proton therapy (3DCPT) in the treatment of cervical cancer. In particular, each technique's ability to spare pelvic bone marrow (PBM) was of primary interest in this study. A total of six cervical cancer...

Descripción completa

Detalles Bibliográficos
Autores principales: Song, William Y., Huh, Soon N., Liang, Yun, White, Greg, Nichols, R. Charles, Watkins, W. Tyler, Mundt, Arno J., Mell, Loren K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720421/
https://www.ncbi.nlm.nih.gov/pubmed/21081882
http://dx.doi.org/10.1120/jacmp.v11i4.3255
_version_ 1783284645303943168
author Song, William Y.
Huh, Soon N.
Liang, Yun
White, Greg
Nichols, R. Charles
Watkins, W. Tyler
Mundt, Arno J.
Mell, Loren K.
author_facet Song, William Y.
Huh, Soon N.
Liang, Yun
White, Greg
Nichols, R. Charles
Watkins, W. Tyler
Mundt, Arno J.
Mell, Loren K.
author_sort Song, William Y.
collection PubMed
description The objective was to compare intensity‐modulated radiation therapy (IMRT) with 3D conformal proton therapy (3DCPT) in the treatment of cervical cancer. In particular, each technique's ability to spare pelvic bone marrow (PBM) was of primary interest in this study. A total of six cervical cancer patients (3 postoperative and 3 intact) were planned and analyzed. All plans had uniform 1.0 cm CTV‐PTV margin and satisfied the 95% PTV with 100% isodose (prescription [Formula: see text]) coverage. Dose‐volume histograms (DVH) were analyzed for comparison. The overall PTV and PBM volumes were [Formula: see text] cc and [Formula: see text] cc, respectively. In terms of PTV dose conformity index (DCI) and dose homogeneity index (DHI), 3DCPT was slightly superior to IMRT with [Formula: see text] , and [Formula: see text] , respectively. In addition, 3DCPT demonstrated superiority in reducing lower doses (i.e., V30 or less) to PBM, small bowel and bladder. Particularly in PBM, average V10 and V20 reductions of 10.8% and [Formula: see text] and 0.04), respectively, were observed. However, in the higher dose range, IMRT provided better sparing [Formula: see text]. For example, in small bowel and PBM, average reductions in V45 of 4.9% and [Formula: see text] and 0.008), respectively, were observed. Due to its physical characteristics such as low entrance dose, spread‐out Bragg peak and finite particle range of protons, 3DCPT illustrated superior target coverage uniformity and sparing of the lower doses in PBM and other organs. Further studies are, however, needed to fully exploit the benefits of protons for general use in cervical cancer. PACS number: 87.55.D‐, 87.55.dk
format Online
Article
Text
id pubmed-5720421
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57204212018-04-02 Dosimetric comparison study between intensity modulated radiation therapy and three‐dimensional conformal proton therapy for pelvic bone marrow sparing in the treatment of cervical cancer Song, William Y. Huh, Soon N. Liang, Yun White, Greg Nichols, R. Charles Watkins, W. Tyler Mundt, Arno J. Mell, Loren K. J Appl Clin Med Phys Radiation Oncology Physics The objective was to compare intensity‐modulated radiation therapy (IMRT) with 3D conformal proton therapy (3DCPT) in the treatment of cervical cancer. In particular, each technique's ability to spare pelvic bone marrow (PBM) was of primary interest in this study. A total of six cervical cancer patients (3 postoperative and 3 intact) were planned and analyzed. All plans had uniform 1.0 cm CTV‐PTV margin and satisfied the 95% PTV with 100% isodose (prescription [Formula: see text]) coverage. Dose‐volume histograms (DVH) were analyzed for comparison. The overall PTV and PBM volumes were [Formula: see text] cc and [Formula: see text] cc, respectively. In terms of PTV dose conformity index (DCI) and dose homogeneity index (DHI), 3DCPT was slightly superior to IMRT with [Formula: see text] , and [Formula: see text] , respectively. In addition, 3DCPT demonstrated superiority in reducing lower doses (i.e., V30 or less) to PBM, small bowel and bladder. Particularly in PBM, average V10 and V20 reductions of 10.8% and [Formula: see text] and 0.04), respectively, were observed. However, in the higher dose range, IMRT provided better sparing [Formula: see text]. For example, in small bowel and PBM, average reductions in V45 of 4.9% and [Formula: see text] and 0.008), respectively, were observed. Due to its physical characteristics such as low entrance dose, spread‐out Bragg peak and finite particle range of protons, 3DCPT illustrated superior target coverage uniformity and sparing of the lower doses in PBM and other organs. Further studies are, however, needed to fully exploit the benefits of protons for general use in cervical cancer. PACS number: 87.55.D‐, 87.55.dk John Wiley and Sons Inc. 2010-08-15 /pmc/articles/PMC5720421/ /pubmed/21081882 http://dx.doi.org/10.1120/jacmp.v11i4.3255 Text en © 2010 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Song, William Y.
Huh, Soon N.
Liang, Yun
White, Greg
Nichols, R. Charles
Watkins, W. Tyler
Mundt, Arno J.
Mell, Loren K.
Dosimetric comparison study between intensity modulated radiation therapy and three‐dimensional conformal proton therapy for pelvic bone marrow sparing in the treatment of cervical cancer
title Dosimetric comparison study between intensity modulated radiation therapy and three‐dimensional conformal proton therapy for pelvic bone marrow sparing in the treatment of cervical cancer
title_full Dosimetric comparison study between intensity modulated radiation therapy and three‐dimensional conformal proton therapy for pelvic bone marrow sparing in the treatment of cervical cancer
title_fullStr Dosimetric comparison study between intensity modulated radiation therapy and three‐dimensional conformal proton therapy for pelvic bone marrow sparing in the treatment of cervical cancer
title_full_unstemmed Dosimetric comparison study between intensity modulated radiation therapy and three‐dimensional conformal proton therapy for pelvic bone marrow sparing in the treatment of cervical cancer
title_short Dosimetric comparison study between intensity modulated radiation therapy and three‐dimensional conformal proton therapy for pelvic bone marrow sparing in the treatment of cervical cancer
title_sort dosimetric comparison study between intensity modulated radiation therapy and three‐dimensional conformal proton therapy for pelvic bone marrow sparing in the treatment of cervical cancer
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720421/
https://www.ncbi.nlm.nih.gov/pubmed/21081882
http://dx.doi.org/10.1120/jacmp.v11i4.3255
work_keys_str_mv AT songwilliamy dosimetriccomparisonstudybetweenintensitymodulatedradiationtherapyandthreedimensionalconformalprotontherapyforpelvicbonemarrowsparinginthetreatmentofcervicalcancer
AT huhsoonn dosimetriccomparisonstudybetweenintensitymodulatedradiationtherapyandthreedimensionalconformalprotontherapyforpelvicbonemarrowsparinginthetreatmentofcervicalcancer
AT liangyun dosimetriccomparisonstudybetweenintensitymodulatedradiationtherapyandthreedimensionalconformalprotontherapyforpelvicbonemarrowsparinginthetreatmentofcervicalcancer
AT whitegreg dosimetriccomparisonstudybetweenintensitymodulatedradiationtherapyandthreedimensionalconformalprotontherapyforpelvicbonemarrowsparinginthetreatmentofcervicalcancer
AT nicholsrcharles dosimetriccomparisonstudybetweenintensitymodulatedradiationtherapyandthreedimensionalconformalprotontherapyforpelvicbonemarrowsparinginthetreatmentofcervicalcancer
AT watkinswtyler dosimetriccomparisonstudybetweenintensitymodulatedradiationtherapyandthreedimensionalconformalprotontherapyforpelvicbonemarrowsparinginthetreatmentofcervicalcancer
AT mundtarnoj dosimetriccomparisonstudybetweenintensitymodulatedradiationtherapyandthreedimensionalconformalprotontherapyforpelvicbonemarrowsparinginthetreatmentofcervicalcancer
AT melllorenk dosimetriccomparisonstudybetweenintensitymodulatedradiationtherapyandthreedimensionalconformalprotontherapyforpelvicbonemarrowsparinginthetreatmentofcervicalcancer