Cargando…

A dosimetric comparison of stereotactic body radiation therapy techniques for lung cancer: robotic versus conventional linac‐based systems

The aim of this study is to compare the dosimetric characteristics of robotic and conventional linac‐based SBRT techniques for lung cancer, and to provide planning guidance for each modality. Eight patients who received linac‐based SBRT were retrospectively included in this study. A dose of 60 Gy gi...

Descripción completa

Detalles Bibliográficos
Autores principales: Ding, Chuxiong, Chang, Cheng‐Hui, Haslam, Joshua, Timmerman, Robert, Solberg, Timothy
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720432/
https://www.ncbi.nlm.nih.gov/pubmed/20717090
http://dx.doi.org/10.1120/jacmp.v11i3.3223
_version_ 1783284647740833792
author Ding, Chuxiong
Chang, Cheng‐Hui
Haslam, Joshua
Timmerman, Robert
Solberg, Timothy
author_facet Ding, Chuxiong
Chang, Cheng‐Hui
Haslam, Joshua
Timmerman, Robert
Solberg, Timothy
author_sort Ding, Chuxiong
collection PubMed
description The aim of this study is to compare the dosimetric characteristics of robotic and conventional linac‐based SBRT techniques for lung cancer, and to provide planning guidance for each modality. Eight patients who received linac‐based SBRT were retrospectively included in this study. A dose of 60 Gy given in three fractions was prescribed to each target. The Synchrony Respiratory Tracking System and a 4D dose calculation methodology were used for CyberKnife and linac‐based SBRT, respectively, to minimize respiratory impact on dose calculation. Identical image and contour sets were used for both modalities. While both modalities can provide satisfactory target dose coverage, the dose to GTV was more heterogeneous for CyberKnife than for linac planning/delivery in all cases. The dose to 1000 cc lung was well below institutional constraints for both modalities. In the high dose region, the lung dose depended on tumor size, and was similar between both modalities. In the low dose region, however, the quality of CyberKnife plans was dependent on tumor location. With anteriorly‐located tumors, the CyberKnife may deliver less dose to normal lung than linac techniques. Conversely, for posteriorly‐located tumors, CyberKnife delivery may result in higher doses to normal lung. In all cases studied, more monitor units were required for CyberKnife delivery for given prescription. Both conventional linacs and CyberKnife provide acceptable target dose coverage while sparing normal tissues. The results of this study provide a general guideline for patient and treatment modality selection based on dosimetric, tumor and normal tissue sparing considerations. PACS numbers: 87.53.Ly, 87.55.dk.
format Online
Article
Text
id pubmed-5720432
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57204322018-04-02 A dosimetric comparison of stereotactic body radiation therapy techniques for lung cancer: robotic versus conventional linac‐based systems Ding, Chuxiong Chang, Cheng‐Hui Haslam, Joshua Timmerman, Robert Solberg, Timothy J Appl Clin Med Phys Radiation Oncology Physics The aim of this study is to compare the dosimetric characteristics of robotic and conventional linac‐based SBRT techniques for lung cancer, and to provide planning guidance for each modality. Eight patients who received linac‐based SBRT were retrospectively included in this study. A dose of 60 Gy given in three fractions was prescribed to each target. The Synchrony Respiratory Tracking System and a 4D dose calculation methodology were used for CyberKnife and linac‐based SBRT, respectively, to minimize respiratory impact on dose calculation. Identical image and contour sets were used for both modalities. While both modalities can provide satisfactory target dose coverage, the dose to GTV was more heterogeneous for CyberKnife than for linac planning/delivery in all cases. The dose to 1000 cc lung was well below institutional constraints for both modalities. In the high dose region, the lung dose depended on tumor size, and was similar between both modalities. In the low dose region, however, the quality of CyberKnife plans was dependent on tumor location. With anteriorly‐located tumors, the CyberKnife may deliver less dose to normal lung than linac techniques. Conversely, for posteriorly‐located tumors, CyberKnife delivery may result in higher doses to normal lung. In all cases studied, more monitor units were required for CyberKnife delivery for given prescription. Both conventional linacs and CyberKnife provide acceptable target dose coverage while sparing normal tissues. The results of this study provide a general guideline for patient and treatment modality selection based on dosimetric, tumor and normal tissue sparing considerations. PACS numbers: 87.53.Ly, 87.55.dk. John Wiley and Sons Inc. 2010-06-29 /pmc/articles/PMC5720432/ /pubmed/20717090 http://dx.doi.org/10.1120/jacmp.v11i3.3223 Text en © 2010 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Ding, Chuxiong
Chang, Cheng‐Hui
Haslam, Joshua
Timmerman, Robert
Solberg, Timothy
A dosimetric comparison of stereotactic body radiation therapy techniques for lung cancer: robotic versus conventional linac‐based systems
title A dosimetric comparison of stereotactic body radiation therapy techniques for lung cancer: robotic versus conventional linac‐based systems
title_full A dosimetric comparison of stereotactic body radiation therapy techniques for lung cancer: robotic versus conventional linac‐based systems
title_fullStr A dosimetric comparison of stereotactic body radiation therapy techniques for lung cancer: robotic versus conventional linac‐based systems
title_full_unstemmed A dosimetric comparison of stereotactic body radiation therapy techniques for lung cancer: robotic versus conventional linac‐based systems
title_short A dosimetric comparison of stereotactic body radiation therapy techniques for lung cancer: robotic versus conventional linac‐based systems
title_sort dosimetric comparison of stereotactic body radiation therapy techniques for lung cancer: robotic versus conventional linac‐based systems
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720432/
https://www.ncbi.nlm.nih.gov/pubmed/20717090
http://dx.doi.org/10.1120/jacmp.v11i3.3223
work_keys_str_mv AT dingchuxiong adosimetriccomparisonofstereotacticbodyradiationtherapytechniquesforlungcancerroboticversusconventionallinacbasedsystems
AT changchenghui adosimetriccomparisonofstereotacticbodyradiationtherapytechniquesforlungcancerroboticversusconventionallinacbasedsystems
AT haslamjoshua adosimetriccomparisonofstereotacticbodyradiationtherapytechniquesforlungcancerroboticversusconventionallinacbasedsystems
AT timmermanrobert adosimetriccomparisonofstereotacticbodyradiationtherapytechniquesforlungcancerroboticversusconventionallinacbasedsystems
AT solbergtimothy adosimetriccomparisonofstereotacticbodyradiationtherapytechniquesforlungcancerroboticversusconventionallinacbasedsystems
AT dingchuxiong dosimetriccomparisonofstereotacticbodyradiationtherapytechniquesforlungcancerroboticversusconventionallinacbasedsystems
AT changchenghui dosimetriccomparisonofstereotacticbodyradiationtherapytechniquesforlungcancerroboticversusconventionallinacbasedsystems
AT haslamjoshua dosimetriccomparisonofstereotacticbodyradiationtherapytechniquesforlungcancerroboticversusconventionallinacbasedsystems
AT timmermanrobert dosimetriccomparisonofstereotacticbodyradiationtherapytechniquesforlungcancerroboticversusconventionallinacbasedsystems
AT solbergtimothy dosimetriccomparisonofstereotacticbodyradiationtherapytechniquesforlungcancerroboticversusconventionallinacbasedsystems