Cargando…

Design and clinical implementation of a TG‐106 compliant linear accelerator data management system and MU calculator

In an attempt to minimize errors and improve patient outcome in radiation therapy, a linear accelerator data management system was developed to provide radiation oncology physicists with a set of computerized tools to manage linear accelerator physics data. The entire program is written in Microsoft...

Descripción completa

Detalles Bibliográficos
Autor principal: Adnani, Nabil
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720439/
https://www.ncbi.nlm.nih.gov/pubmed/20717087
http://dx.doi.org/10.1120/jacmp.v11i3.3212
_version_ 1783284649418555392
author Adnani, Nabil
author_facet Adnani, Nabil
author_sort Adnani, Nabil
collection PubMed
description In an attempt to minimize errors and improve patient outcome in radiation therapy, a linear accelerator data management system was developed to provide radiation oncology physicists with a set of computerized tools to manage linear accelerator physics data. The entire program is written in Microsoft Visual Basic and has a user‐friendly, front‐end window with the following features and modules: (1) Generate, edit and approve commissioning and QA reports and other regulatory documents, (2) Configure commissioning tasks, (3) Acquire output factors, (4) Import scanned data, (5) Import PDD, TMRs and OAR tables directly from the scanning software, (6) Query physics data such as TMR, PDDs, OFs, and WFs, (7) Compare physics data to a different machine or a standard, (8) Compare physics data from the same machine (e.g. during annual calibrations), (9) Perform MU calculations on plans exported from the planning system via DICOM RT, (10) Perform TG‐51 calibration, (11) Perform monthly calibration, (12) FTP physics data for purposes of remote peer review and/or inspections. PACS numbers: 87.53.Dq, 87.55.Qr, 87.56.Fc
format Online
Article
Text
id pubmed-5720439
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57204392018-04-02 Design and clinical implementation of a TG‐106 compliant linear accelerator data management system and MU calculator Adnani, Nabil J Appl Clin Med Phys Radiation Oncology Physics In an attempt to minimize errors and improve patient outcome in radiation therapy, a linear accelerator data management system was developed to provide radiation oncology physicists with a set of computerized tools to manage linear accelerator physics data. The entire program is written in Microsoft Visual Basic and has a user‐friendly, front‐end window with the following features and modules: (1) Generate, edit and approve commissioning and QA reports and other regulatory documents, (2) Configure commissioning tasks, (3) Acquire output factors, (4) Import scanned data, (5) Import PDD, TMRs and OAR tables directly from the scanning software, (6) Query physics data such as TMR, PDDs, OFs, and WFs, (7) Compare physics data to a different machine or a standard, (8) Compare physics data from the same machine (e.g. during annual calibrations), (9) Perform MU calculations on plans exported from the planning system via DICOM RT, (10) Perform TG‐51 calibration, (11) Perform monthly calibration, (12) FTP physics data for purposes of remote peer review and/or inspections. PACS numbers: 87.53.Dq, 87.55.Qr, 87.56.Fc John Wiley and Sons Inc. 2010-04-30 /pmc/articles/PMC5720439/ /pubmed/20717087 http://dx.doi.org/10.1120/jacmp.v11i3.3212 Text en © 2010 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Adnani, Nabil
Design and clinical implementation of a TG‐106 compliant linear accelerator data management system and MU calculator
title Design and clinical implementation of a TG‐106 compliant linear accelerator data management system and MU calculator
title_full Design and clinical implementation of a TG‐106 compliant linear accelerator data management system and MU calculator
title_fullStr Design and clinical implementation of a TG‐106 compliant linear accelerator data management system and MU calculator
title_full_unstemmed Design and clinical implementation of a TG‐106 compliant linear accelerator data management system and MU calculator
title_short Design and clinical implementation of a TG‐106 compliant linear accelerator data management system and MU calculator
title_sort design and clinical implementation of a tg‐106 compliant linear accelerator data management system and mu calculator
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720439/
https://www.ncbi.nlm.nih.gov/pubmed/20717087
http://dx.doi.org/10.1120/jacmp.v11i3.3212
work_keys_str_mv AT adnaninabil designandclinicalimplementationofatg106compliantlinearacceleratordatamanagementsystemandmucalculator