Cargando…
The effect of a limited number of projections and reconstruction algorithms on the image quality of megavoltage digital tomosynthesis
In order to investigate the effect of the number of projections on digital tomosynthesis image quality, images were acquired over a 40 degree arc and sampled into sets of 2 to 41 projections used as input to three different reconstruction algorithms: the shift‐and‐add, the Feldkamp‐Davis‐Kress filte...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720546/ https://www.ncbi.nlm.nih.gov/pubmed/19692978 http://dx.doi.org/10.1120/jacmp.v10i3.2970 |
_version_ | 1783284671776292864 |
---|---|
author | Sarkar, Vikren Shi, Chengyu Rassiah‐Szegedi, Prema Diaz, Aidnag Eng, Tony Papanikolaou, Niko |
author_facet | Sarkar, Vikren Shi, Chengyu Rassiah‐Szegedi, Prema Diaz, Aidnag Eng, Tony Papanikolaou, Niko |
author_sort | Sarkar, Vikren |
collection | PubMed |
description | In order to investigate the effect of the number of projections on digital tomosynthesis image quality, images were acquired over a 40 degree arc and sampled into sets of 2 to 41 projections used as input to three different reconstruction algorithms: the shift‐and‐add, the Feldkamp‐Davis‐Kress filtered back projection algorithms, and the simultaneous algebraic reconstruction technique. The variation of several image characteristics, such as in‐plane resolution, contrast to noise ratio, artifact spread, volumetric accuracy, and dose, are investigated based on the reconstruction algorithms used and also the number of projections used as source data. The results suggest that only 11 projections are required since the various parameters checked do not improve much past that number. As a reconstruction algorithm, SART did best but took much longer to reconstruct images. Thus, if reconstruction time is a determining factor, filtered back‐projection looks like a better compromise. PACS number: 87.57.C‐, 87.57.nf, 87.57.Q‐, 87.59.‐e |
format | Online Article Text |
id | pubmed-5720546 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-57205462018-04-02 The effect of a limited number of projections and reconstruction algorithms on the image quality of megavoltage digital tomosynthesis Sarkar, Vikren Shi, Chengyu Rassiah‐Szegedi, Prema Diaz, Aidnag Eng, Tony Papanikolaou, Niko J Appl Clin Med Phys Medical Imaging In order to investigate the effect of the number of projections on digital tomosynthesis image quality, images were acquired over a 40 degree arc and sampled into sets of 2 to 41 projections used as input to three different reconstruction algorithms: the shift‐and‐add, the Feldkamp‐Davis‐Kress filtered back projection algorithms, and the simultaneous algebraic reconstruction technique. The variation of several image characteristics, such as in‐plane resolution, contrast to noise ratio, artifact spread, volumetric accuracy, and dose, are investigated based on the reconstruction algorithms used and also the number of projections used as source data. The results suggest that only 11 projections are required since the various parameters checked do not improve much past that number. As a reconstruction algorithm, SART did best but took much longer to reconstruct images. Thus, if reconstruction time is a determining factor, filtered back‐projection looks like a better compromise. PACS number: 87.57.C‐, 87.57.nf, 87.57.Q‐, 87.59.‐e John Wiley and Sons Inc. 2009-05-28 /pmc/articles/PMC5720546/ /pubmed/19692978 http://dx.doi.org/10.1120/jacmp.v10i3.2970 Text en © 2009 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Medical Imaging Sarkar, Vikren Shi, Chengyu Rassiah‐Szegedi, Prema Diaz, Aidnag Eng, Tony Papanikolaou, Niko The effect of a limited number of projections and reconstruction algorithms on the image quality of megavoltage digital tomosynthesis |
title | The effect of a limited number of projections and reconstruction algorithms on the image quality of megavoltage digital tomosynthesis |
title_full | The effect of a limited number of projections and reconstruction algorithms on the image quality of megavoltage digital tomosynthesis |
title_fullStr | The effect of a limited number of projections and reconstruction algorithms on the image quality of megavoltage digital tomosynthesis |
title_full_unstemmed | The effect of a limited number of projections and reconstruction algorithms on the image quality of megavoltage digital tomosynthesis |
title_short | The effect of a limited number of projections and reconstruction algorithms on the image quality of megavoltage digital tomosynthesis |
title_sort | effect of a limited number of projections and reconstruction algorithms on the image quality of megavoltage digital tomosynthesis |
topic | Medical Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720546/ https://www.ncbi.nlm.nih.gov/pubmed/19692978 http://dx.doi.org/10.1120/jacmp.v10i3.2970 |
work_keys_str_mv | AT sarkarvikren theeffectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis AT shichengyu theeffectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis AT rassiahszegediprema theeffectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis AT diazaidnag theeffectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis AT engtony theeffectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis AT papanikolaouniko theeffectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis AT sarkarvikren effectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis AT shichengyu effectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis AT rassiahszegediprema effectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis AT diazaidnag effectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis AT engtony effectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis AT papanikolaouniko effectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis |