Cargando…

The effect of a limited number of projections and reconstruction algorithms on the image quality of megavoltage digital tomosynthesis

In order to investigate the effect of the number of projections on digital tomosynthesis image quality, images were acquired over a 40 degree arc and sampled into sets of 2 to 41 projections used as input to three different reconstruction algorithms: the shift‐and‐add, the Feldkamp‐Davis‐Kress filte...

Descripción completa

Detalles Bibliográficos
Autores principales: Sarkar, Vikren, Shi, Chengyu, Rassiah‐Szegedi, Prema, Diaz, Aidnag, Eng, Tony, Papanikolaou, Niko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720546/
https://www.ncbi.nlm.nih.gov/pubmed/19692978
http://dx.doi.org/10.1120/jacmp.v10i3.2970
_version_ 1783284671776292864
author Sarkar, Vikren
Shi, Chengyu
Rassiah‐Szegedi, Prema
Diaz, Aidnag
Eng, Tony
Papanikolaou, Niko
author_facet Sarkar, Vikren
Shi, Chengyu
Rassiah‐Szegedi, Prema
Diaz, Aidnag
Eng, Tony
Papanikolaou, Niko
author_sort Sarkar, Vikren
collection PubMed
description In order to investigate the effect of the number of projections on digital tomosynthesis image quality, images were acquired over a 40 degree arc and sampled into sets of 2 to 41 projections used as input to three different reconstruction algorithms: the shift‐and‐add, the Feldkamp‐Davis‐Kress filtered back projection algorithms, and the simultaneous algebraic reconstruction technique. The variation of several image characteristics, such as in‐plane resolution, contrast to noise ratio, artifact spread, volumetric accuracy, and dose, are investigated based on the reconstruction algorithms used and also the number of projections used as source data. The results suggest that only 11 projections are required since the various parameters checked do not improve much past that number. As a reconstruction algorithm, SART did best but took much longer to reconstruct images. Thus, if reconstruction time is a determining factor, filtered back‐projection looks like a better compromise. PACS number: 87.57.C‐, 87.57.nf, 87.57.Q‐, 87.59.‐e
format Online
Article
Text
id pubmed-5720546
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57205462018-04-02 The effect of a limited number of projections and reconstruction algorithms on the image quality of megavoltage digital tomosynthesis Sarkar, Vikren Shi, Chengyu Rassiah‐Szegedi, Prema Diaz, Aidnag Eng, Tony Papanikolaou, Niko J Appl Clin Med Phys Medical Imaging In order to investigate the effect of the number of projections on digital tomosynthesis image quality, images were acquired over a 40 degree arc and sampled into sets of 2 to 41 projections used as input to three different reconstruction algorithms: the shift‐and‐add, the Feldkamp‐Davis‐Kress filtered back projection algorithms, and the simultaneous algebraic reconstruction technique. The variation of several image characteristics, such as in‐plane resolution, contrast to noise ratio, artifact spread, volumetric accuracy, and dose, are investigated based on the reconstruction algorithms used and also the number of projections used as source data. The results suggest that only 11 projections are required since the various parameters checked do not improve much past that number. As a reconstruction algorithm, SART did best but took much longer to reconstruct images. Thus, if reconstruction time is a determining factor, filtered back‐projection looks like a better compromise. PACS number: 87.57.C‐, 87.57.nf, 87.57.Q‐, 87.59.‐e John Wiley and Sons Inc. 2009-05-28 /pmc/articles/PMC5720546/ /pubmed/19692978 http://dx.doi.org/10.1120/jacmp.v10i3.2970 Text en © 2009 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Medical Imaging
Sarkar, Vikren
Shi, Chengyu
Rassiah‐Szegedi, Prema
Diaz, Aidnag
Eng, Tony
Papanikolaou, Niko
The effect of a limited number of projections and reconstruction algorithms on the image quality of megavoltage digital tomosynthesis
title The effect of a limited number of projections and reconstruction algorithms on the image quality of megavoltage digital tomosynthesis
title_full The effect of a limited number of projections and reconstruction algorithms on the image quality of megavoltage digital tomosynthesis
title_fullStr The effect of a limited number of projections and reconstruction algorithms on the image quality of megavoltage digital tomosynthesis
title_full_unstemmed The effect of a limited number of projections and reconstruction algorithms on the image quality of megavoltage digital tomosynthesis
title_short The effect of a limited number of projections and reconstruction algorithms on the image quality of megavoltage digital tomosynthesis
title_sort effect of a limited number of projections and reconstruction algorithms on the image quality of megavoltage digital tomosynthesis
topic Medical Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720546/
https://www.ncbi.nlm.nih.gov/pubmed/19692978
http://dx.doi.org/10.1120/jacmp.v10i3.2970
work_keys_str_mv AT sarkarvikren theeffectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis
AT shichengyu theeffectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis
AT rassiahszegediprema theeffectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis
AT diazaidnag theeffectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis
AT engtony theeffectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis
AT papanikolaouniko theeffectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis
AT sarkarvikren effectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis
AT shichengyu effectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis
AT rassiahszegediprema effectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis
AT diazaidnag effectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis
AT engtony effectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis
AT papanikolaouniko effectofalimitednumberofprojectionsandreconstructionalgorithmsontheimagequalityofmegavoltagedigitaltomosynthesis