Expected clinical impact of the differences between planned and delivered dose distributions in helical tomotherapy for treating head and neck cancer using helical megavoltage CT images

Helical Tomotherapy (HT) has become increasingly popular over the past few years. However, its clinical efficacy and effectiveness continues to be investigated. Pre‐treatment patient repositioning in highly conformal image‐guided radiation therapy modalities is a prerequisite for reducing setup unce...

Descripción completa

Detalles Bibliográficos
Autores principales: Mavroidis, Panayiotis, Stathakis, Sotirios, Gutierrez, Alonso, Esquivel, Carlos, Shi, Chenyu, Papanikolaou, Nikos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720549/
https://www.ncbi.nlm.nih.gov/pubmed/19692977
http://dx.doi.org/10.1120/jacmp.v10i3.2969
_version_ 1783284672508198912
author Mavroidis, Panayiotis
Stathakis, Sotirios
Gutierrez, Alonso
Esquivel, Carlos
Shi, Chenyu
Papanikolaou, Nikos
author_facet Mavroidis, Panayiotis
Stathakis, Sotirios
Gutierrez, Alonso
Esquivel, Carlos
Shi, Chenyu
Papanikolaou, Nikos
author_sort Mavroidis, Panayiotis
collection PubMed
description Helical Tomotherapy (HT) has become increasingly popular over the past few years. However, its clinical efficacy and effectiveness continues to be investigated. Pre‐treatment patient repositioning in highly conformal image‐guided radiation therapy modalities is a prerequisite for reducing setup uncertainties. A MVCT image set has to be acquired to account for daily changes in the patient's internal anatomy and setup position. Furthermore, a comparison should be performed to the kVCT study used for dosimetric planning, by a registration process that results in repositioning the patient according to specific transitional and rotational shifts. Different image registration techniques may lead to different repositioning of the patient and, as a result, to varying delivered doses. This study aims to investigate the expected effect of patient setup correction using the Hi·Art TomoTherapy system by employing radiobiological measures such as the biologically effective uniform dose [Formula: see text] and the complication‐free tumor control probability [Formula: see text]. In this study, a typical case of lung cancer with metastatic head and neck disease was investigated by developing a Helical Tomotherapy plan. For the TomoTherapy Hi·Art plan, the dedicated tomotherapy treatment planning station was used. Three dose distributions (planned and delivered with and without patient setup correction) were compared based on radiobiological measures by using the [Formula: see text] index and the [Formula: see text] concept as the common prescription point of the plans, and plotting the tissue response probabilities against the mean target dose for a range of prescription doses. The applied plan evaluation method shows that, in this cancer case, the planned and delivered dose distributions with and without patient setup correction give a [Formula: see text] of 81.6%, 80.9% and 72.2%, for a [Formula: see text] to the planning target volume (PTV) of 78.0Gy, 77.7Gy and 75.4Gy, respectively. The corresponding tumor control probabilities are 86.3%, 85.1% and 75.1%, whereas the total complication probabilities are 4.64%, 4.20% and 2.89%, respectively. HT can encompass the often large PTV required while minimizing the volume of the organs at risk receiving high dose. However, the effectiveness of an HT treatment plan can be considerably deteriorated if an accurate patient setup system is not available. Taking into account the dose‐response relations of the irradiated tumors and normal tissues, a radiobiological treatment plan evaluation can be performed, which may provide a closer association of the delivered treatment with the clinical outcome. In such situations, for effective evaluation and comparison of different treatment plans, traditional dose based evaluation tools can be complemented by the use of [Formula: see text] diagrams. PACS number: 87.55.Qr Quality assurance in radiotherapy
format Online
Article
Text
id pubmed-5720549
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57205492018-04-02 Expected clinical impact of the differences between planned and delivered dose distributions in helical tomotherapy for treating head and neck cancer using helical megavoltage CT images Mavroidis, Panayiotis Stathakis, Sotirios Gutierrez, Alonso Esquivel, Carlos Shi, Chenyu Papanikolaou, Nikos J Appl Clin Med Phys Radiation Oncology Physics Helical Tomotherapy (HT) has become increasingly popular over the past few years. However, its clinical efficacy and effectiveness continues to be investigated. Pre‐treatment patient repositioning in highly conformal image‐guided radiation therapy modalities is a prerequisite for reducing setup uncertainties. A MVCT image set has to be acquired to account for daily changes in the patient's internal anatomy and setup position. Furthermore, a comparison should be performed to the kVCT study used for dosimetric planning, by a registration process that results in repositioning the patient according to specific transitional and rotational shifts. Different image registration techniques may lead to different repositioning of the patient and, as a result, to varying delivered doses. This study aims to investigate the expected effect of patient setup correction using the Hi·Art TomoTherapy system by employing radiobiological measures such as the biologically effective uniform dose [Formula: see text] and the complication‐free tumor control probability [Formula: see text]. In this study, a typical case of lung cancer with metastatic head and neck disease was investigated by developing a Helical Tomotherapy plan. For the TomoTherapy Hi·Art plan, the dedicated tomotherapy treatment planning station was used. Three dose distributions (planned and delivered with and without patient setup correction) were compared based on radiobiological measures by using the [Formula: see text] index and the [Formula: see text] concept as the common prescription point of the plans, and plotting the tissue response probabilities against the mean target dose for a range of prescription doses. The applied plan evaluation method shows that, in this cancer case, the planned and delivered dose distributions with and without patient setup correction give a [Formula: see text] of 81.6%, 80.9% and 72.2%, for a [Formula: see text] to the planning target volume (PTV) of 78.0Gy, 77.7Gy and 75.4Gy, respectively. The corresponding tumor control probabilities are 86.3%, 85.1% and 75.1%, whereas the total complication probabilities are 4.64%, 4.20% and 2.89%, respectively. HT can encompass the often large PTV required while minimizing the volume of the organs at risk receiving high dose. However, the effectiveness of an HT treatment plan can be considerably deteriorated if an accurate patient setup system is not available. Taking into account the dose‐response relations of the irradiated tumors and normal tissues, a radiobiological treatment plan evaluation can be performed, which may provide a closer association of the delivered treatment with the clinical outcome. In such situations, for effective evaluation and comparison of different treatment plans, traditional dose based evaluation tools can be complemented by the use of [Formula: see text] diagrams. PACS number: 87.55.Qr Quality assurance in radiotherapy John Wiley and Sons Inc. 2009-07-21 /pmc/articles/PMC5720549/ /pubmed/19692977 http://dx.doi.org/10.1120/jacmp.v10i3.2969 Text en © 2009 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Mavroidis, Panayiotis
Stathakis, Sotirios
Gutierrez, Alonso
Esquivel, Carlos
Shi, Chenyu
Papanikolaou, Nikos
Expected clinical impact of the differences between planned and delivered dose distributions in helical tomotherapy for treating head and neck cancer using helical megavoltage CT images
title Expected clinical impact of the differences between planned and delivered dose distributions in helical tomotherapy for treating head and neck cancer using helical megavoltage CT images
title_full Expected clinical impact of the differences between planned and delivered dose distributions in helical tomotherapy for treating head and neck cancer using helical megavoltage CT images
title_fullStr Expected clinical impact of the differences between planned and delivered dose distributions in helical tomotherapy for treating head and neck cancer using helical megavoltage CT images
title_full_unstemmed Expected clinical impact of the differences between planned and delivered dose distributions in helical tomotherapy for treating head and neck cancer using helical megavoltage CT images
title_short Expected clinical impact of the differences between planned and delivered dose distributions in helical tomotherapy for treating head and neck cancer using helical megavoltage CT images
title_sort expected clinical impact of the differences between planned and delivered dose distributions in helical tomotherapy for treating head and neck cancer using helical megavoltage ct images
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720549/
https://www.ncbi.nlm.nih.gov/pubmed/19692977
http://dx.doi.org/10.1120/jacmp.v10i3.2969
work_keys_str_mv AT mavroidispanayiotis expectedclinicalimpactofthedifferencesbetweenplannedanddelivereddosedistributionsinhelicaltomotherapyfortreatingheadandneckcancerusinghelicalmegavoltagectimages
AT stathakissotirios expectedclinicalimpactofthedifferencesbetweenplannedanddelivereddosedistributionsinhelicaltomotherapyfortreatingheadandneckcancerusinghelicalmegavoltagectimages
AT gutierrezalonso expectedclinicalimpactofthedifferencesbetweenplannedanddelivereddosedistributionsinhelicaltomotherapyfortreatingheadandneckcancerusinghelicalmegavoltagectimages
AT esquivelcarlos expectedclinicalimpactofthedifferencesbetweenplannedanddelivereddosedistributionsinhelicaltomotherapyfortreatingheadandneckcancerusinghelicalmegavoltagectimages
AT shichenyu expectedclinicalimpactofthedifferencesbetweenplannedanddelivereddosedistributionsinhelicaltomotherapyfortreatingheadandneckcancerusinghelicalmegavoltagectimages
AT papanikolaounikos expectedclinicalimpactofthedifferencesbetweenplannedanddelivereddosedistributionsinhelicaltomotherapyfortreatingheadandneckcancerusinghelicalmegavoltagectimages