Cargando…

Effect of collimator and couch angle change on breast IMRT dose distributions

Intensity‐modulated tangential photon beams for breast cancer treatment can improve the dose uniformity significantly throughout the whole breast and reduce the dose to the lung and the heart when compared to the conventional technique. Before the first treatment, patient setup may require a change...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Jie, Ma, Charlie, Wang, Lu, Chen, Lili, Li, Jinsheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720579/
https://www.ncbi.nlm.nih.gov/pubmed/19918233
http://dx.doi.org/10.1120/jacmp.v10i4.3058
_version_ 1783284679571406848
author Yang, Jie
Ma, Charlie
Wang, Lu
Chen, Lili
Li, Jinsheng
author_facet Yang, Jie
Ma, Charlie
Wang, Lu
Chen, Lili
Li, Jinsheng
author_sort Yang, Jie
collection PubMed
description Intensity‐modulated tangential photon beams for breast cancer treatment can improve the dose uniformity significantly throughout the whole breast and reduce the dose to the lung and the heart when compared to the conventional technique. Before the first treatment, patient setup may require a change on the collimator angle and/or the couch angle based on the chest wall coverage according to the port films. The objective of this work is to investigate the effects of the collimator and the couch angle change on the dose distribution for breast cancer treatment using intensity‐modulated tangential photon beams, and to determine the clinical acceptable range of the angle change for routine treatment. Ten breast cases treated with intensity‐modulated tangential photon beams were analyzed in this study. Patient‐specific CT data and the radiation therapy planning (RTP) files obtained from our in‐house Monte Carlo based breast IMRT treatment planning system were used for IMRT dose recalculation with collimator or couch angle changes. The isodose distributions and DVHs were compared with the original plans, and the effects of the collimator and couch angle change to breast IMRT dose distributions were evaluated. Our results show that a 4° change in the collimator angle or the couch angle did not affect the dose distribution significantly and it is acceptable in the clinic for patient treatment. PACS number: 87.10.Rt
format Online
Article
Text
id pubmed-5720579
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57205792018-04-02 Effect of collimator and couch angle change on breast IMRT dose distributions Yang, Jie Ma, Charlie Wang, Lu Chen, Lili Li, Jinsheng J Appl Clin Med Phys Radiation Oncology Physics Intensity‐modulated tangential photon beams for breast cancer treatment can improve the dose uniformity significantly throughout the whole breast and reduce the dose to the lung and the heart when compared to the conventional technique. Before the first treatment, patient setup may require a change on the collimator angle and/or the couch angle based on the chest wall coverage according to the port films. The objective of this work is to investigate the effects of the collimator and the couch angle change on the dose distribution for breast cancer treatment using intensity‐modulated tangential photon beams, and to determine the clinical acceptable range of the angle change for routine treatment. Ten breast cases treated with intensity‐modulated tangential photon beams were analyzed in this study. Patient‐specific CT data and the radiation therapy planning (RTP) files obtained from our in‐house Monte Carlo based breast IMRT treatment planning system were used for IMRT dose recalculation with collimator or couch angle changes. The isodose distributions and DVHs were compared with the original plans, and the effects of the collimator and couch angle change to breast IMRT dose distributions were evaluated. Our results show that a 4° change in the collimator angle or the couch angle did not affect the dose distribution significantly and it is acceptable in the clinic for patient treatment. PACS number: 87.10.Rt John Wiley and Sons Inc. 2009-09-30 /pmc/articles/PMC5720579/ /pubmed/19918233 http://dx.doi.org/10.1120/jacmp.v10i4.3058 Text en © 2009 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Yang, Jie
Ma, Charlie
Wang, Lu
Chen, Lili
Li, Jinsheng
Effect of collimator and couch angle change on breast IMRT dose distributions
title Effect of collimator and couch angle change on breast IMRT dose distributions
title_full Effect of collimator and couch angle change on breast IMRT dose distributions
title_fullStr Effect of collimator and couch angle change on breast IMRT dose distributions
title_full_unstemmed Effect of collimator and couch angle change on breast IMRT dose distributions
title_short Effect of collimator and couch angle change on breast IMRT dose distributions
title_sort effect of collimator and couch angle change on breast imrt dose distributions
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720579/
https://www.ncbi.nlm.nih.gov/pubmed/19918233
http://dx.doi.org/10.1120/jacmp.v10i4.3058
work_keys_str_mv AT yangjie effectofcollimatorandcouchanglechangeonbreastimrtdosedistributions
AT macharlie effectofcollimatorandcouchanglechangeonbreastimrtdosedistributions
AT wanglu effectofcollimatorandcouchanglechangeonbreastimrtdosedistributions
AT chenlili effectofcollimatorandcouchanglechangeonbreastimrtdosedistributions
AT lijinsheng effectofcollimatorandcouchanglechangeonbreastimrtdosedistributions